*Starting Up Zūm Wired with SHOWRUNNER™
Version 6.1 by Alexander Mott on 2023/03/28 19:00
n/a
n/a
CONTENTS
Lorem
See Figure 1 for details.
See Figure 2 for details.
Start-Up Guide
Lorem
cross reference/update to old zumnet startup?
basic steps:
- configure your processor per chief's startup guide
- get all zumnet jbox online
- use built in dhcp from processor control subnet
- if using proc without control subnet, use showrunner dhcp
- (will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json)
- use crestron toolbox device discovery to create a Device Summary
- use chief tools tm tool to generate various zum wired load scripts
- (need to determine exact process for this; will need to add IP-ID and new hostname to device summary somehow)
- (will likely generate two versions of the loadscripts; one connecting by default hostname and one connecting by new hostname)
- (intend to require SR license for zwired LS generator, if only to get the proc mac address)
- if firmware is old, run "zwms master/zum (def. hostname)" loadscript to make all ZUMNET JBOX primary and in app mode in order to enable discovery of devices on zumlink
- devices will reboot
- per crestron, 1.0006.00012 and newer ship in primary mode (tbd if they will ship in app mode?)
- connect to a few devices in device discovery tool to ensure that all zumlink devices were automatically readdressed and there are no conflicting cids
- firmware 1.0001.00081 is new enough that this works correctly
- run "fw update (def. hostname)" loadscript to update the fw for all devices
- will take up to several minutes per room, but will be able to do up to 10 rooms simultaneously
- devices will reboot, possibly multiple times
- check loadscript manager for any failures and re-run script for those devices if necessary (a rebooting zumnet box will temporarily disrupt online status for downstream zumnet jboxs and potentially interrupt the firmware update)
- run device discovery again to confirm that all zumnet boxes were updated
- zumnet boxes update last, so if a zumnet jbox is updated then this means that all of the zumlink devices that were online have also been updated
- if app mode backup is desired, configure the boxes using the app now
- run "ip config (def. hostname)" loadscript to update device IP-IDs and hostnames
- devices will reboot
- devices will now have new hostnames, so any further loadscripts should use (new hostname) versions
- run "cnet mode (def. hostname)" loadscript to put devices into CNET mode
- if app mode backup is desired, also run "autoswitch enable (def. hostname)" loadscript
- devices will reboot
- if using a processor without control subnet, run the "static ip config (new hostname)" script
- this loadscript is necessary, as the showrunner DHCP server is only intended for commissioning. It must always be manually started after program restart and should not be used in production
- (will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json)
- once done, commission job essentially as normal showrunner job
- (sr commissioning guide is incomplete)
- connect to each zumnet jbox and address zumlink devices per the takeoff
- if devices are not online, then troubleshoot why and update firmware through device tree view once they are online
- occ timeouts can be adjusted through UI; other settings (ie reach) should be adjusted through app
- photocells etc are set up through UI
- loads teseted and verified through UI; can be moved around between controllers as necessary
- loads don't need to be in the same room as the zumnet that controls them
- keypads can use standard SR types or be fully customized
- set up schedule, etc.
- once done, save and back up configuration file