Scott Kohlmann 25.1 1 ShowRunnerCLC™ runs on Crestron 3-series and 4-series control systems.
Mark Kohlmann 1.1 2
3
4 === Minimum Requirements ===
5
Mark Kohlmann 16.1 6 * Dedicated 3-series (DIN-AP3/CP3/CP3N/AV3/PRO3/RMC3) or 4-series control system.  Running other programs on the processor is not recommended.  VC-4 is also supported.
Mark Kohlmann 4.1 7 * Due to hardware/firmware differences the MC3 is not recommended and has not been tested.
Mark Kohlmann 1.1 8
9 === Supported Hardware ===
10
Scott Kohlmann 25.1 11 ShowRunnerCLC™ supports a large collection of Crestron hardware and lighting related products.
Mark Kohlmann 1.1 12
Mark Kohlmann 16.1 13 * Cresnet Bridges: CAEN-BLOCK-CENCN-2-POE/DIN-CENCN-2(-POE)/CSA-PWS10S-HUB-ENET/ZUMNET-JBOX
Mark Kohlmann 1.1 14 * Lighting Controllers:
Mark Kohlmann 15.1 15 ** Crestron CLS-C6 (Scene Recall/Load Control)
16 ** Crestron CLF/CLFI
17 ** Crestron CLW-Series: CLW-DELVEX-E, CLW-DELVEX-P, CLW-DIMEX-E, CLW-DIMEX-P, CLW-DIMFLVEX-P, CLW-DIMSWEX-E, CLW-DIMSWEX-P, CLW-LDIMEX1/2, CLW-LSWEX1/2
Mark Kohlmann 1.1 18 ** Crestron CLX-Series: CLX-1DELV4, CLX-1DIM4, CLX-1DIMU4, CLX-1DIMU4-HP, CLX-1DIM8, CLX-2DIM8, CLX-2DIMU8, CLX-2DIM2, CLX-2DIMFLV8, CLX-4HSW4, CLX-1FAN4 (As a load)
Mark Kohlmann 24.1 19 ** Crestron DIN-Series: DIN-DALI-2, DIN-AO8, DIN-1DIM4, DIN-1DIMU4, DIN-4DIMLV4, DIN-8SW8, DIN-8SW8-I, DIN-2LEDPWM8, DIN-IO8
Mark Kohlmann 15.1 20 ** Crestron GL-CAEN (See Crestron CLX)
Mark Kohlmann 1.1 21 ** Crestron GL-EXP-Series: GL-EXP-DIMU-CN, GL-EXP-DIMFDB-CN, GL-EXP-DIMFLV-CN, GL-EXP-SWCN
22 ** Crestron GLPP-Series: GLPP-DIMFLVCN-PM, GLPP-1DIMFLV(2|3)CN-PM, GLPP-SWCN, GLPP-1SW(2|3)CN
23 ** Crestron GLX-Series: GLX-DIM6, GLX-DIMFLV8, GLX-HSW8
24 ** Crestron GLXP-Series: GLXP-DIMFLV8, GLXP-HSW12, GLXP-HSW8, GLXP-SW10, GLXP-SW16, GLXX-2DIM8, GLXX-CTRL
25 ** Crestron GLPAC-Series (via EISC): 4 or 8 channel, supports GLPAC Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
26 ** Crestron GL-IPAC (via EISC): 8 channel, supports local Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
Mark Kohlmann 16.1 27 ** Crestron HZ-*EX Series
Mark Kohlmann 1.1 28 ** Crestron EISC: Loads directly attached to an EISC with RCB support (3-series or classic)
Mark Kohlmann 15.1 29 ** Crestron Relay: Any low voltage Crestron relay
Mark Kohlmann 24.1 30 ** Crestron Versiport
Mark Kohlmann 1.1 31 ** Crestron ZUMMESH Wireless: Entire Zum Wireless product line with direct load control, occupancy, photocell via ZUMMESH-NETBRIDGE
32 ** Crestron ZUMMESH-AVBRIDGE (via Serial Port): Direct Load Control, Keypad, Occupancy, Photocell
Mark Kohlmann 9.1 33 ** Crestron Zum Wired NET/LINK controllers and keypads
Mark Kohlmann 1.1 34 ** DMX: sACN, Art-Net (RDM Addressing Supported), Pharos LPC Series (Fixture/Group Control and Timeline Playback)
Mark Kohlmann 15.1 35 ** 3rd Party
36 *** BACnet: Remote BACnet load
Mark Kohlmann 24.1 37 *** ETC: Paradigm PSAP
Mark Kohlmann 15.1 38 *** Lutron: Integration Protocol Loads and Areas via RS-232 or IP
39 *** Philips iPlayer3: Master Intensity and Show Playback
Mark Kohlmann 24.1 40 *** WTEC SmartDirector/SmartEngine: Locations as loads or area and Fixtures as loads, virtual load tracking
Mark Kohlmann 1.1 41 * Keypads
42 ** C2N-CBD Series
Mark Kohlmann 6.1 43 ** C2N-CBF Series
Mark Kohlmann 1.1 44 ** C2N-LCDB3
Mark Kohlmann 6.1 45 ** C2NI-CB
46 ** CNX-Bx Series
Mark Kohlmann 1.1 47 ** CLW-Series
Mark Kohlmann 15.1 48 ** CLWI-Series
Mark Kohlmann 13.1 49 ** GLPPA-KP (KP1/KP2/KP3/KP4 are NOT supported for programming due to hardware limitation)
Mark Kohlmann 6.1 50 ** HTT-B10EX
51 ** HTT-B2EX
Mark Kohlmann 15.1 52 ** HZ-KPCN/EX
53 ** HZ-*EX Load Controllers
Mark Kohlmann 1.1 54 ** INET-CBDEX
Mark Kohlmann 9.1 55 ** ZUMLINK-KP
Mark Kohlmann 1.1 56 ** Zum AV Keypad via AVBRIDGE
57 * Occupancy Sensors
58 ** Cresnet Sensors: GLS-ODT-C-CN, GLS-OIR-C-CN, GLS-OIRLCL-C-CN
Mark Kohlmann 15.1 59 ** Steinel Sensors (via Contact Closure)
Mark Kohlmann 1.1 60 ** Wireless Sensors: GLS-OIR-CSM-EX-BATT
Mark Kohlmann 24.1 61 ** Zum Wired: ZUMLINK sensors
Mark Kohlmann 1.1 62 ** Zum Wireless: NETBRIDGE or AVBRIDGE (via Serial Port)
63 ** Non-System: Contact Closure via GLS-SIM, C2N-CBD-P, GLPP, GLPAC/GL-IPAC, DIN-IO8, or EISC
64 *** Crestron NS sensors
65 *** Steinel
66 *** Third-Party Sensors
67 * Photocells
68 ** Daylight Harvesting: GLS-LOL, GLS-LCL, GLS-LCCT (not recommended for harvesting), GLS-LDL-EX-BATT, 3rd Party 0-10V Open or Closed Loop connected via GLS-SIM, C2N-CBD-P, GLS-ODT-C-CN, GLPP, GLPAC, DIN-IO8, or Processor
69 ** Exterior: GLS-LEXT via GLS-SIM, C2N-CBD-P, DIN-IO8, or Processor. GLS-LCCT (SolarSync)
70 ** SolarSync/CCT: GLS-LCCT
71 * Partition Sensors
72 ** GLS-PART-CN (Supports Sensitivity Adjustment)
73 ** 3rd Party via Versiport (GLS-SIM/DIN-IO8/GLPAC)
74 * Override Input: ​Keyswitches/FACP/Power Loss Sensor/Alarm/Emergency Input/Demand Response
75 ** Keyswitch: Maintained or Momentary via GLS-SIM, C2N-CBD-P, C2N-CBF-P, CLWI-KPLCN, HZ-KPCN, DIN-IO8, or Processor
76 ** External Input: Maintained (Invertable) via GLS-SIM, C2N-CBD-P, C2N-CBF-P, CLWI-KPLCN, HZ-KPCN, DIN-IO8, or Processor
Mark Kohlmann 24.1 77 * HVAC
78 ** Carrier BACnet
79 ** Ecobee
80 ** Crestron CHV-TSTATEX-FCU
Mark Kohlmann 7.1 81 * Shades
82 ** Crestron: C2N-SDC, CSC series, CSM/CSMI Series (QMT), Relay/Versiport, EISC
Mark Kohlmann 15.1 83 ** DraperFlex: HTTP via Gateway
Mark Kohlmann 8.1 84 ** Lutron: Sivoia QS, Quantum (Telnet/RS-232)
Mark Kohlmann 15.1 85 ** Mecho: MechoNET (RS-232), SolarTrac4 (BACnet)
86 ** Somfy: SDN [UAI+ RS-232/Telnet | POE Gateway | RS-485], RTS (URTSII RS-232/RS-485)
Mark Kohlmann 1.1 87 * User Interfaces
88 ** Crestron App - iPhone (Local control only, no setup)
89 ** Crestron App - iPad Landscape
90 ** XPanel Executable (Smart Graphics)
Mark Kohlmann 24.1 91 ** showrunner™ Hub HTML5 UI (v3.0 and greater)
Scott Kohlmann 20.1 92 ** TSW-750/752/760/770
93 ** TSW-1050/1052/1060/1070
94 ** TSW-560/570 (Local control only, no setup)*
95 ** TSW-560P/570P (Local control only, no setup)*
Mark Kohlmann 24.1 96 * Integration Interfaces
97 ** Crestron Serial Port: Processor, C2N-IO, CEN-IO-COM, INET-IOEX-IRCOM
Scott Kohlmann 20.1 98
99 *TSW 570 UI: No setup option, only splash and area select/control
100
101 [[image:MicrosoftTeams-image316c8d50d322901fc07d30c8922806254932f267ae5a223d5e797018dcf331fb.png||height="422" width="750"]]
102
103
104
105 *TSW 570P: Vertical sliders with horizontal scrolling
106
107 [[image:MicrosoftTeams-image3e8f52a09e1ed115f0557f825fe3c151f77c2079e13fc1d711e582028891ca61.png||height="750" width="421"]]
108
109