Hardware Requirements and Supported Hardware
Last modified by Alexander Mott on 2026/05/11 18:08
CONTENTS
ShowRunnerCLC™ runs on Crestron 3-series and 4-series control systems.
List of supported hardware is not exhaustive, contact Chief Integrations for questions about particular models.
Minimum Requirements
- Dedicated 3-series (DIN-AP3/CP3/CP3N/AV3/PRO3/RMC3) or 4-series control system, including VC-4.
- Running other programs on the processor is not recommended.
- The MC3 is not recommended due to hardware/firmware differences and has not been tested.
Supported Hardware
ShowRunnerCLC™ supports a large collection of Crestron hardware and lighting related products.
Cresnet Bridges
- CAEN-BLOCK-CENCN-2-POE
- DIN-CENCN-2(-POE)
- CSA-PWS10S-HUB-ENET
- ZUMNET-JBOX-16A-LV / DALI
- ZUMNET-DIN-16A-LV / DLI
Lighting / Load Controllers
- Crestron:
- CLS-C6 (Scene Recall/Load Control)
- CLF/CLFI
- CLW-Series:
- CLW-DELVEX-P / CLW-DELVEX-E
- CLW-DIMEX-P / CLW-DIMEX-E
- CLW-DIMFLVEX-P
- CLW-DIMSWEX-P / CLW-DIMSWEX-E,
- CLW-LDIMEX1 / CLW-LDIMEX2
- CLW-LSWEX1 / CLW-LSWEX2
- CLX Series (GL-CAEN Modules):
- CLX-1DELV4
- CLX-1DIM4
- CLX-1DIMU4 / CLX-1DIMU4-HP
- CLX-1DIM8 / CLX-2DIM2 / CLX-2DIM8 / CLX-2DIMU8
- CLX-2DIMFLV8
- CLX-4HSW4
- CLX-1FAN4 (Controlled as switched load)
- DIN Series:
- DIN-DALI-2
- DIN-AO8 (0-10V dimming only; no load control)
- DIN-1DIM4 / DIN-1DIMU4
- DIN-4DIMFLV4
- DIN-8SW8, DIN-8SW8-I, DIN-2LEDPWM8, DIN-IO8
- GL-EXP Series: GL-EXP-DIMU-CN, GL-EXP-DIMFDB-CN, GL-EXP-DIMFLV-CN, GL-EXP-SWCN
- GLPP Series: GLPP-DIMFLVCN-PM, GLPP-1DIMFLV(2|3)CN-PM, GLPP-SWCN, GLPP-1SW(2|3)CN
- GLX Series: GLX-DIM6, GLX-DIMFLV8, GLX-HSW8
- GLXP Series: GLXP-DIMFLV8, GLXP-HSW12, GLXP-HSW8, GLXP-SW10, GLXP-SW16, GLXX-2DIM8, GLXX-CTRL
- GLPAC Series via EISC: 4 or 8 channel, supports GLPAC Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
- GL-IPAC via EISC: 8 channel, supports local Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
- HZ-*EX Series
- Relay: Any low voltage Crestron relay
- ZUMMESH Wireless: Entire Zum Wireless product line with direct load control, occupancy, photocell via ZUMMESH-NETBRIDGE
- ZUMMESH-AVBRIDGE (via Serial Port) Direct Load Control, Keypad, Occupancy, Photocell
- Zum Wired Series:
- ZUMNET-JBOX-16A-LV / DALI
- ZUMLINK-JBOX-16A-LV / 20A-SW / 20A-PLUG, ZUMLINK-EXP-16A-DIMU
- ZUMNET-DIN-16A-LV / DLI
- ZUMLINK-DIN-16A-LV / 20A-SW / 20A-PLUG / DIMU
- Crestron Versiport
- EISC: Loads directly attached to an EISC with RCB support (3-series or classic)
- DMX: sACN, Art-Net (RDM Addressing Supported), Pharos LPC Series (Fixture/Group Control and Timeline Playback)
- 3rd Party
- BACnet: Remote BACnet load
- ETC: Paradigm PSAP
- Lutron: Integration Protocol Loads and Areas via RS-232 or IP
- Philips iPlayer3: Master Intensity and Show Playback
- WTEC SmartDirector/SmartEngine: Locations as loads or area and Fixtures as loads, virtual load tracking
Contact Closure / Override Inputs
- Contact-closure capable devices:
- GLS-SIM
- C2N-CBD-P
- CM2-HZCN
- GLS-ODT-C-CN
- GLPP-*
- GLPAC-*
- DIN-IO8
- Zum Wired Series:
- ZUMNET-JBOX-16A-LV / DALI
- ZUMLINK-JBOX-16A-LV / 20A-SW / 20A-PLUG
- ZUMLINK-JBOX-IO
- ZUMNET-DIN-16A-LV / DLI
- ZUMLINK-DIN-16A-LV / 20A-SW / 20A-PLUG / EXP-DIMU
- ZUMLINK-DIN-IO
- Processor (varies by model)
- Override Input Methods:
- Keyswitch (see below)
- FACP
- Power Loss Sensor (GLS-PLS-120/277)
- Alarm
- Emergency Input
- Demand Response
Keypads
- C2N-CBD Series
- C2N-CBF Series
- C2N-LCDB3
- C2NI-CB
- CM2-KPCN
- CNX-Bx Series
- CLW-Series
- CLWI-Series
- GLPPA-KP (KP1/KP2/KP3/KP4 are NOT supported for programming due to hardware limitation)
- HTT-B10EX
- HTT-B2EX
- HZ-KPCN/EX
- HZ-*EX Load Controllers
- INET-CBDEX
- ZUMLINK-KP
- Zum AV Keypad via AVBRIDGE
Occupancy Sensors
- Cresnet:
- GLS-ODT-C-CN
- GLS-OIR-C-CN
- GLS-OIRLCL-C-CN
- ZUMLINK Sensors
- GLS-OIR-CSM-EX-BATT
- Zum Wireless NETBRIDGE or AVBRIDGE (via Serial Port)
- Third-party / Contact closure sensors (requires Crestron device with contact-closure or dedicated occupancy input):
- Crestron "NS" sensors
- Steinel Sensors
- SensorWorx
- Any third-party sensor with 24VDC output
Photocells
- Daylight Harvesting
- GLS-LOL
- GLS-LCL
- GLS-LDL
- GLS-LCCT (not recommended for harvesting)
- GLS-LDL-EX-BATT
- 3rd Party 0-10V Open or Closed Loop connected via:
- GLS-SIM
- C2N-CBD-P
- GLS-ODT-C-CN
- GLPP
- GLPAC
- DIN-IO8
- ZUMNET- / ZUMLINK-JBOX
- Processor (varies by model)
- Exterior
- GLS-LEXT via contact closure:
- GLS-SIM
- C2N-CBD-P
- DIN-IO8
- Processor
- GLS-LCCT
- GLS-LEXT via contact closure:
- SolarSync/CCT
- GLS-LCCT
Partition Sensors
- GLS-PART-CN (Supports Sensitivity Adjustment)
- Third-party via contact closure
Keyswitch
- Maintained or Momentary input via contact closure:
- GLS-SIM
- C2N-CBD-P Cameo Keypad
- C2N-CBF-P
- CLWI-KPLCN
- HZ-KPCN
- DIN-IO8
- Processor
- External Input
- Maintained (Invertable) via:
- GLS-SIM
- C2N-CBD-P
- C2N-CBF-P
- CLWI-KPLCN
- HZ-KPCN
- DIN-IO8
- Processor
- Maintained (Invertable) via:
HVAC
- Crestron:
- CHV-TSTATEX-FCU
- Third-Party:
- Carrier BACnet
- Ecobee
Shades
- Crestron:
- C2N-SDC
- CSC series
- CSM/CSMI Series (QMT)
- Relay/Versiport, EISC
- Third-Party:
- DraperFlexHTTP via Gateway
- Lutron:
- Sivoia QS
- Quantum (Telnet/RS-232)
- Mecho
- MechoNET (RS-232)
- SolarTrac4 (BACnet)
- Somfy
- SDN [UAI+ RS-232/Telnet | POE Gateway | RS-485]
- RTS (URTSII RS-232/RS-485)
Integration Interfaces
- Crestron Serial Port (RS-232/RS-485) via:
- Processor (certain models only)
- C2N-IO
- CEN-IO-COM
- INET-IOEX-IRCOM
User Interfaces
- ShowRunnerCLC™ Hub HTML5 UI (ShowRunnerCLC™ v3.0 and greater)
- XPanel Executable (Smart Graphics)
- Crestron App - iPhone (Local control only, no setup)
- Crestron App - iPad Landscape
- TSW-750 / 752 / 760 / 770
- TSW-1050 / 1052 / 1060 / 1070
- TSW-560 / 570 (No setup menu, area overview/control only)*
- TSW-560P / 570P (Vertical sliders; area overview/control only)**
TSW-570: No setup menu, only splash and area overview:

**TSW-570P: Vertical sliders with horizontal scrolling for additional sliders; no setup menu