3 {{/box}}
4
5 ShowRunnerCLC™ runs on Crestron 3-series and 4-series control systems.
6
7 List of supported hardware is not exhaustive, contact Chief Integrations for questions about particular models.
8
9 = Minimum Requirements =
10
11 * Dedicated 3-series (DIN-AP3/CP3/CP3N/AV3/PRO3/RMC3) or 4-series control system, including VC-4.
12 ** Running other programs on the processor is not recommended.
13 * The MC3 is not recommended due to hardware/firmware differences and has not been tested.
14
15 = Supported Hardware =
16
17 ShowRunnerCLC™ supports a large collection of Crestron hardware and lighting related products.
18
19 == Cresnet Bridges ==
20
21 * CAEN-BLOCK-CENCN-2-POE
22 * DIN-CENCN-2(-POE)
23 * CSA-PWS10S-HUB-ENET
24 * ZUMNET-JBOX-16A-LV / DALI
25 * ZUMNET-DIN-16A-LV / DLI
26
27 == Lighting / Load Controllers ==
28
29 * Crestron:
30 ** CLS-C6 (Scene Recall/Load Control)
31 ** CLF/CLFI
32 ** CLW-Series:
33 *** CLW-DELVEX-P / CLW-DELVEX-E
34 *** CLW-DIMEX-P / CLW-DIMEX-E
35 *** CLW-DIMFLVEX-P
36 *** CLW-DIMSWEX-P / CLW-DIMSWEX-E,
37 *** CLW-LDIMEX1 / CLW-LDIMEX2
38 *** CLW-LSWEX1 / CLW-LSWEX2
39 ** CLX Series (GL-CAEN Modules):
40 *** CLX-1DELV4
41 *** CLX-1DIM4
42 *** CLX-1DIMU4 / CLX-1DIMU4-HP
43 *** CLX-1DIM8 / CLX-2DIM2 / CLX-2DIM8 / CLX-2DIMU8
44 *** CLX-2DIMFLV8
45 *** CLX-4HSW4
46 *** CLX-1FAN4 (Controlled as switched load)
47 ** DIN Series:
48 *** DIN-DALI-2
49 *** DIN-AO8 (0-10V dimming only; no load control)
50 *** DIN-1DIM4 / DIN-1DIMU4
51 *** DIN-4DIMFLV4
52 *** DIN-8SW8, DIN-8SW8-I, DIN-2LEDPWM8, DIN-IO8
53 ** GL-EXP Series: GL-EXP-DIMU-CN, GL-EXP-DIMFDB-CN, GL-EXP-DIMFLV-CN, GL-EXP-SWCN
54 ** GLPP Series: GLPP-DIMFLVCN-PM, GLPP-1DIMFLV(2|3)CN-PM, GLPP-SWCN, GLPP-1SW(2|3)CN
55 ** GLX Series: GLX-DIM6, GLX-DIMFLV8, GLX-HSW8
56 ** GLXP Series: GLXP-DIMFLV8, GLXP-HSW12, GLXP-HSW8, GLXP-SW10, GLXP-SW16, GLXX-2DIM8, GLXX-CTRL
57 ** GLPAC Series via EISC: 4 or 8 channel, supports GLPAC Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
58 ** GL-IPAC via EISC: 8 channel, supports local Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
59 ** HZ-*EX Series
60 ** Relay: Any low voltage Crestron relay
61 ** ZUMMESH Wireless: Entire Zum Wireless product line with direct load control, occupancy, photocell via ZUMMESH-NETBRIDGE
62 ** ZUMMESH-AVBRIDGE (via Serial Port) Direct Load Control, Keypad, Occupancy, Photocell
63 ** Zum Wired Series:
64 *** ZUMNET-JBOX-16A-LV / DALI
65 *** ZUMLINK-JBOX-16A-LV / 20A-SW / 20A-PLUG, ZUMLINK-EXP-16A-DIMU
66 *** ZUMNET-DIN-16A-LV / DLI
67 *** ZUMLINK-DIN-16A-LV / 20A-SW / 20A-PLUG / DIMU
68 ** Crestron Versiport
69 ** EISC: Loads directly attached to an EISC with RCB support (3-series or classic)
70 ** DMX: sACN, Art-Net (RDM Addressing Supported), Pharos LPC Series (Fixture/Group Control and Timeline Playback)
71 * 3rd Party
72 ** BACnet: Remote BACnet load
73 ** ETC: Paradigm PSAP
74 ** Lutron: Integration Protocol Loads and Areas via RS-232 or IP
75 ** Philips iPlayer3: Master Intensity and Show Playback
76 ** WTEC SmartDirector/SmartEngine: Locations as loads or area and Fixtures as loads, virtual load tracking
77
78 == Contact Closure / Override Inputs ==
79
80 * ​Contact-closure capable devices:
81 ** GLS-SIM
82 ** C2N-CBD-P
83 ** CM2-HZCN
84 ** GLS-ODT-C-CN
85 ** GLPP-*
86 ** GLPAC-*
87 ** DIN-IO8
88 ** Zum Wired Series:
89 *** ZUMNET-JBOX-16A-LV / DALI
90 *** ZUMLINK-JBOX-16A-LV / 20A-SW / 20A-PLUG
91 *** ZUMLINK-JBOX-IO
92 *** ZUMNET-DIN-16A-LV / DLI
93 *** ZUMLINK-DIN-16A-LV / 20A-SW / 20A-PLUG / EXP-DIMU
94 *** ZUMLINK-DIN-IO
95 ** Processor (varies by model)
96 * Override Input Methods:
97 ** Keyswitch (see below)
98 ** FACP
99 ** Power Loss Sensor (GLS-PLS-120/277)
100 ** Alarm
101 ** Emergency Input
102 ** Demand Response
103
104 == Keypads ==
105
106 * C2N-CBD Series
107 * C2N-CBF Series
108 * C2N-LCDB3
109 * C2NI-CB
110 * CM2-KPCN
111 * CNX-Bx Series
112 * CLW-Series
113 * CLWI-Series
114 * GLPPA-KP (KP1/KP2/KP3/KP4 are NOT supported for programming due to hardware limitation)
115 * HTT-B10EX
116 * HTT-B2EX
117 * HZ-KPCN/EX
118 * HZ-*EX Load Controllers
119 * INET-CBDEX
120 * ZUMLINK-KP
121 * Zum AV Keypad via AVBRIDGE
122
123 == Occupancy Sensors ==
124
125 * Cresnet:
126 ** GLS-ODT-C-CN
127 ** GLS-OIR-C-CN
128 ** GLS-OIRLCL-C-CN
129 *
130 *
131 * ZUMLINK Sensors
132 * GLS-OIR-CSM-EX-BATT
133 * Zum Wireless NETBRIDGE or AVBRIDGE (via Serial Port)
134 * Third-party / Contact closure sensors (requires Crestron device with contact-closure or dedicated occupancy input):
135 ** Crestron "NS" sensors
136 ** Steinel Sensors
137 ** SensorWorx
138 ** Any third-party sensor with 24VDC output
139
140 == Photocells ==
141
142 * Daylight Harvesting
143 ** GLS-LOL
144 ** GLS-LCL
145 ** GLS-LDL
146 ** GLS-LCCT (not recommended for harvesting)
147 ** GLS-LDL-EX-BATT
148 ** 3rd Party 0-10V Open or Closed Loop connected via:
149 *** GLS-SIM
150 *** C2N-CBD-P
151 *** GLS-ODT-C-CN
152 *** GLPP
153 *** GLPAC
154 *** DIN-IO8
155 *** ZUMNET- / ZUMLINK-JBOX
156 *** Processor (varies by model)
157 * Exterior
158 ** GLS-LEXT via contact closure:
159 *** GLS-SIM
160 *** C2N-CBD-P
161 *** DIN-IO8
162 *** Processor
163 ** GLS-LCCT
164 * SolarSync/CCT
165 ** GLS-LCCT
166
167 == Partition Sensors ==
168
169 * GLS-PART-CN (Supports Sensitivity Adjustment)
170 * Third-party via contact closure
171
172 == Keyswitch ==
173
174 * Maintained or Momentary input via contact closure:
175 ** GLS-SIM
176 ** C2N-CBD-P Cameo Keypad
177 ** C2N-CBF-P
178 ** CLWI-KPLCN
179 ** HZ-KPCN
180 ** DIN-IO8
181 ** Processor
182 * External Input
183 ** Maintained (Invertable) via:
184 *** GLS-SIM
185 *** C2N-CBD-P
186 *** C2N-CBF-P
187 *** CLWI-KPLCN
188 *** HZ-KPCN
189 *** DIN-IO8
190 *** Processor
191
192 == HVAC ==
193
194 * Crestron:
195 ** CHV-TSTATEX-FCU
196 * Third-Party:
197 ** Carrier BACnet
198 ** Ecobee
199
200 == Shades ==
201
202 * Crestron:
203 ** C2N-SDC
204 ** CSC series
205 ** CSM/CSMI Series (QMT)
206 ** Relay/Versiport, EISC
207 * Third-Party:
208 ** DraperFlexHTTP via Gateway
209 ** Lutron:
210 *** Sivoia QS
211 *** Quantum (Telnet/RS-232)
212 ** Mecho
213 *** MechoNET (RS-232)
214 *** SolarTrac4 (BACnet)
215 ** Somfy
216 *** SDN [UAI+ RS-232/Telnet | POE Gateway | RS-485]
217 *** RTS (URTSII RS-232/RS-485)
218
219 == Integration Interfaces ==
220
221 * Crestron Serial Port (RS-232/RS-485) via:
222 ** Processor (certain models only)
223 ** C2N-IO
224 ** CEN-IO-COM
225 ** INET-IOEX-IRCOM
226
227 == User Interfaces ==
228
229 * ShowRunnerCLC™ Hub HTML5 UI (ShowRunnerCLC™ v3.0 and greater)
230 * XPanel Executable (Smart Graphics)
231 * Crestron App - iPhone (Local control only, no setup)
232 * Crestron App - iPad Landscape
233 * TSW-750 / 752 / 760 / 770
234 * TSW-1050 / 1052 / 1060 / 1070
235 * TSW-560 / 570 (No setup menu, area overview/control only)*
236 * TSW-560P / 570P (Vertical sliders; area overview/control only)~*~*
237
238 **TSW-570**: No setup menu, only splash and area overview:
239
240 [[image:MicrosoftTeams-image316c8d50d322901fc07d30c8922806254932f267ae5a223d5e797018dcf331fb.png||height="422" width="750"]]
241
242 ~*~***TSW-570P**: Vertical sliders with horizontal scrolling for additional sliders; no setup menu
243
244 [[image:MicrosoftTeams-image3e8f52a09e1ed115f0557f825fe3c151f77c2079e13fc1d711e582028891ca61.png||height="750" width="421"]]