Show last authors
1 (% class="box warningmessage" %)
2 (((
3 Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into ShowRunnerCLC™.  [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient.
4 )))
5
6 ShowRunnerCLC™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using more than 50 channels on the DMX input.  Use as few channels as possible and try not to send fades over DMX into the Pharos.
7
8 Steps:
9
10 ShowRunnerCLC™
11
12 1. Enable [[UDP Listener>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.UDP Input.WebHome]] in the ShowRunnerCLC™ config:
13
14 "UdpListener":
15 {
16 "ListenPort": 45794
17 },
18
19 Pharos Config:
20
21 1. Create a new Pharos Project or Open an Existing One
22 1. Go to Project->Project Features and set DMX In under Trigger to Enabled
23 1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input
24 1. Triggers
25 11. Create a trigger on each DMX Input that you wish to send to ShowRunnerCLC™
26 11. Set Trigger Parameters:
27 111. Channel: Channel # you wish to capture
28 111. Changes in range: Minimum: 0 Maximum: 255
29 11. New Action: Output Ethernet
30 111. Enable Variables
31 111. IP/Hostname: IP Address or Hostname of the processor running ShowRunnerCLC™
32 111. Port: 45794
33 111. Protocol: UDP
34 111. String: "GID.SetLevelByByte.<3>\r"
35 1111. GID is the GlobalID for the load within ShowRunnerCLC™
36 111. Example DMX Channel 41 controlling load with global ID of 32:
37 [[image:1597260805025-107.png||height="58" width="693"]]
38