Changes for page DMX Input via Pharos

Last modified by Alexander Mott on 2024/06/14 18:25

From version 9.1
edited by Scott Kohlmann
on 2023/04/20 21:24
Change comment: There is no comment for this version
To version 3.1
edited by Mark Kohlmann
on 2021/06/30 17:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Integrations Guide.Integration Options.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.scott\.kohlmann@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,15 +1,10 @@
1 -(% class="box warningmessage" %)
2 -(((
3 -Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into ShowRunnerCLC™.  [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient.
4 -)))
1 +SHOWRUNNER™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using anymore than 50 channels on the DMX input.
5 5  
6 -ShowRunnerCLC™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using more than 50 channels on the DMX input.  Use as few channels as possible and try not to send fades over DMX into the Pharos.
7 -
8 8  Steps:
9 9  
10 -ShowRunnerCLC
5 +SHOWRUNNER
11 11  
12 -1. Enable [[UDP Listener>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.UDP Input.WebHome]] in the ShowRunnerCLC™ config:
7 +1. Enable [[UDP Listener>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.UDP Input.WebHome]] in the SHOWRUNNER™ config:
13 13  
14 14   "UdpListener":
15 15   {
... ... @@ -22,17 +22,17 @@
22 22  1. Go to Project->Project Features and set DMX In under Trigger to Enabled
23 23  1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input
24 24  1. Triggers
25 -11. Create a trigger on each DMX Input that you wish to send to ShowRunnerCLC
20 +11. Create a trigger on each DMX Input that you wish to send to SHOWRUNNER
26 26  11. Set Trigger Parameters:
27 27  111. Channel: Channel # you wish to capture
28 28  111. Changes in range: Minimum: 0 Maximum: 255
29 29  11. New Action: Output Ethernet
30 30  111. Enable Variables
31 -111. IP/Hostname: IP Address or Hostname of the processor running ShowRunnerCLC
26 +111. IP/Hostname: IP Address or Hostname of the processor running SHOWRUNNER
32 32  111. Port: 45794
33 33  111. Protocol: UDP
34 34  111. String: "GID.SetLevelByByte.<3>\r"
35 -1111. GID is the GlobalID for the load within ShowRunnerCLC
30 +1111. GID is the GlobalID for the load within SHOWRUNNER
36 36  111. Example DMX Channel 41 controlling load with global ID of 32:
37 37  [[image:1597260805025-107.png||height="58" width="693"]]
38 38