DMX Input via Pharos
Version 9.1 by Scott Kohlmann on 2023/04/20 21:24
ShowRunnerCLC™ can accept commands from a Pharos' DMX input. Note: Pharos recommends not using more than 50 channels on the DMX input. Use as few channels as possible and try not to send fades over DMX into the Pharos.
Steps:
ShowRunnerCLC™
- Enable UDP Listener in the ShowRunnerCLC™ config:
"UdpListener":
{
"ListenPort": 45794
},
Pharos Config:
- Create a new Pharos Project or Open an Existing One
- Go to Project->Project Features and set DMX In under Trigger to Enabled
- Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input
- Triggers
- Create a trigger on each DMX Input that you wish to send to ShowRunnerCLC™
- Set Trigger Parameters:
- Channel: Channel # you wish to capture
- Changes in range: Minimum: 0 Maximum: 255
- New Action: Output Ethernet
- Enable Variables
- IP/Hostname: IP Address or Hostname of the processor running ShowRunnerCLC™
- Port: 45794
- Protocol: UDP
- String: "GID.SetLevelByByte.<3>\r"
- GID is the GlobalID for the load within ShowRunnerCLC™
- Example DMX Channel 41 controlling load with global ID of 32: