Changes for page DMX Input via Pharos
Last modified by Alexander Mott on 2024/06/14 18:25
From version 1.1
edited by Mark Kohlmann
on 2020/08/12 19:33
on 2020/08/12 19:33
Change comment:
Uploaded new attachment "1597260805025-107.png", version {1}
To version 9.1
edited by Scott Kohlmann
on 2023/04/20 21:24
on 2023/04/20 21:24
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +DMX Input via Pharos - Parent
-
... ... @@ -1,0 +1,1 @@ 1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,0 +1,39 @@ 1 +(% class="box warningmessage" %) 2 +((( 3 +Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into ShowRunnerCLC™. [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient. 4 +))) 5 + 6 +ShowRunnerCLC™ can accept commands from a Pharos' DMX input. Note: Pharos recommends not using more than 50 channels on the DMX input. Use as few channels as possible and try not to send fades over DMX into the Pharos. 7 + 8 +Steps: 9 + 10 +ShowRunnerCLC™ 11 + 12 +1. Enable [[UDP Listener>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.UDP Input.WebHome]] in the ShowRunnerCLC™ config: 13 + 14 + "UdpListener": 15 + { 16 + "ListenPort": 45794 17 + }, 18 + 19 +Pharos Config: 20 + 21 +1. Create a new Pharos Project or Open an Existing One 22 +1. Go to Project->Project Features and set DMX In under Trigger to Enabled 23 +1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input 24 +1. Triggers 25 +11. Create a trigger on each DMX Input that you wish to send to ShowRunnerCLC™ 26 +11. Set Trigger Parameters: 27 +111. Channel: Channel # you wish to capture 28 +111. Changes in range: Minimum: 0 Maximum: 255 29 +11. New Action: Output Ethernet 30 +111. Enable Variables 31 +111. IP/Hostname: IP Address or Hostname of the processor running ShowRunnerCLC™ 32 +111. Port: 45794 33 +111. Protocol: UDP 34 +111. String: "GID.SetLevelByByte.<3>\r" 35 +1111. GID is the GlobalID for the load within ShowRunnerCLC™ 36 +111. Example DMX Channel 41 controlling load with global ID of 32: 37 +[[image:1597260805025-107.png||height="58" width="693"]] 38 + 39 +