SHOWRUNNER™ Hardware Requirements and Supported Hardware
Version 1.1 by Mark Kohlmann on 2020/04/05 03:43
SHOWRUNNER™ runs on Crestron 3-series and 4-series control systems.
Minimum Requirements
- Dedicated 3-series (DIN-AP3/CP3/CP3N/AV3/PRO3/RMC3) or 4-series control system. Running other programs on the processor is not recommended.
- Supported Crestron lighting hardware
Supported Hardware
SHOWRUNNER™ supports a large collection of Crestron hardware and lighting related products.
- Cresnet Bridges: CAEN-BLOCK-CENCN-2-POE/DIN-CENCN-2(-POE)/CSA-PWS10S-HUB-ENET
- Lighting Controllers:
- Crestron CLX-Series: CLX-1DELV4, CLX-1DIM4, CLX-1DIMU4, CLX-1DIMU4-HP, CLX-1DIM8, CLX-2DIM8, CLX-2DIMU8, CLX-2DIM2, CLX-2DIMFLV8, CLX-4HSW4, CLX-1FAN4 (As a load)
- Crestron DIN-Series: DIN-DALI-2, DIN-AO8, DIN-1DIM4, DIN-1DIMU4, DIN-4DIMLV4, DIN-8SW8, DIN-8SW8-I, DIN-2LEDPWM8
- Crestron GL-EXP-Series: GL-EXP-DIMU-CN, GL-EXP-DIMFDB-CN, GL-EXP-DIMFLV-CN, GL-EXP-SWCN
- Crestron GLPP-Series: GLPP-DIMFLVCN-PM, GLPP-1DIMFLV(2|3)CN-PM, GLPP-SWCN, GLPP-1SW(2|3)CN
- Crestron GLX-Series: GLX-DIM6, GLX-DIMFLV8, GLX-HSW8
- Crestron GLXP-Series: GLXP-DIMFLV8, GLXP-HSW12, GLXP-HSW8, GLXP-SW10, GLXP-SW16, GLXX-2DIM8, GLXX-CTRL
- Crestron CLS-C6 (Scene Recall/Load Control)
- Crestron CLW-Series: CLW-DELVEX-E, CLW-DELVEX-P, CLW-DIMEX-E, CLW-DIMEX-P, CLW-DIMFLVEX-P, CLW-DIMSWEX-E, CLW-DIMSWEX-P, CLW-LDIMEX1/2, CLW-LSWEX1/2
- Crestron GLPAC-Series (via EISC): 4 or 8 channel, supports GLPAC Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
- Crestron GL-IPAC (via EISC): 8 channel, supports local Occupancy and Photocell inputs, and locally attached Cresnet expansion modules
- Crestron EISC: Loads directly attached to an EISC with RCB support (3-series or classic)
- Crestron ZUMMESH Wireless: Entire Zum Wireless product line with direct load control, occupancy, photocell via ZUMMESH-NETBRIDGE
- Crestron ZUMMESH-AVBRIDGE (via Serial Port): Direct Load Control, Keypad, Occupancy, Photocell
- DMX: sACN, Art-Net (RDM Addressing Supported), Pharos LPC Series (Fixture/Group Control and Timeline Playback)
- Keypads
- C2N-CBD Series
- C2N-LCDB3
- CLW-Series
- GLPPA-KP
- HZ-KPCN
- INET-CBDEX
- Zum AV Keypad via AVBRIDGE
- Occupancy Sensors
- Cresnet Sensors: GLS-ODT-C-CN, GLS-OIR-C-CN, GLS-OIRLCL-C-CN
- Wireless Sensors: GLS-OIR-CSM-EX-BATT
- Zum Wireless: NETBRIDGE or AVBRIDGE (via Serial Port)
- Non-System: Contact Closure via GLS-SIM, C2N-CBD-P, GLPP, GLPAC/GL-IPAC, DIN-IO8, or EISC
- Crestron NS sensors
- Steinel
- Third-Party Sensors
- Photocells
- Daylight Harvesting: GLS-LOL, GLS-LCL, GLS-LCCT (not recommended for harvesting), GLS-LDL-EX-BATT, 3rd Party 0-10V Open or Closed Loop connected via GLS-SIM, C2N-CBD-P, GLS-ODT-C-CN, GLPP, GLPAC, DIN-IO8, or Processor
- Exterior: GLS-LEXT via GLS-SIM, C2N-CBD-P, DIN-IO8, or Processor. GLS-LCCT (SolarSync)
- SolarSync/CCT: GLS-LCCT
- Partition Sensors
- GLS-PART-CN (Supports Sensitivity Adjustment)
- 3rd Party via Versiport (GLS-SIM/DIN-IO8/GLPAC)
- Override Input: Keyswitches/FACP/Power Loss Sensor/Alarm/Emergency Input/Demand Response
- Keyswitch: Maintained or Momentary via GLS-SIM, C2N-CBD-P, C2N-CBF-P, CLWI-KPLCN, HZ-KPCN, DIN-IO8, or Processor
- External Input: Maintained (Invertable) via GLS-SIM, C2N-CBD-P, C2N-CBF-P, CLWI-KPLCN, HZ-KPCN, DIN-IO8, or Processor
- User Interfaces
- TSW-560 (Local control only, no setup)
- TSW-560P (Local control only, no setup)
- TSW-750/752/760
- TSW-1050/1052/1060
- Crestron App - iPhone (Local control only, no setup)
- Crestron App - iPad Landscape
- XPanel Web (Smart Graphics)
- XPanel Executable (Smart Graphics)