Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 4.2
edited by Mark Kohlmann
on 2022/10/14 18:39
on 2022/10/14 18:39
Change comment:
There is no comment for this version
To version 5.2
edited by Mark Kohlmann
on 2022/10/16 17:23
on 2022/10/16 17:23
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 - SHOWRUNNER™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.1 +showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. 2 2 3 3 ==== Area Features ==== 4 4 ... ... @@ -6,6 +6,7 @@ 6 6 * Scene recall 7 7 * Master raise/lower 8 8 * User configurable scene name, fade time, and load include by scene 9 +* Individual scenes may be locked to prevent changing their settings 9 9 * Individual load control within an area 10 10 * Select area from touchpanel, areas can be restricted by panel 11 11 * RGB controls for applicable fixtures, saved per scene ... ... @@ -14,7 +14,6 @@ 14 14 ** CCT Control per area for applicable fixtures 15 15 ** Global schedule for CCT, astronomical and/or fixed schedules 16 16 ** Manual CCT override per area 17 -** Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 18 18 * Demand Response with ability to exclude area from Demand Response event 19 19 * Configurable load grouping allows aggregation of loads to a single slider per group, can include linked areas 20 20 * HVAC Control ... ... @@ -31,6 +31,7 @@ 31 31 * After Hours support for automatic shutoff after configurable timeout w/ alerting 32 32 * Parent Area feature allows one area to trickle down scene recall and raise/lower (if enabled) 33 33 * Last Scene Recall timestamp and triggering action recorded 34 +* Organized in a node tree with multiple depths 34 34 35 35 ==== Load Features ==== 36 36 ... ... @@ -67,7 +67,7 @@ 67 67 * Demand Response Level 68 68 * Enable/Disable/Override states 69 69 * Option to ignore long fade times if the loads is off 70 -* Option recall last level 71 +* Option recall last on level 71 71 * Individual daylight harvesting settings, enabled/disabled by scene 72 72 ** Open/closed loop 73 73 ** Min/Max levels ... ... @@ -87,7 +87,6 @@ 87 87 * DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode) 88 88 ** Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 89 89 90 -(% class="wikigeneratedid" %) 91 91 ==== Scheduling Features ==== 92 92 93 93 * Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day ... ... @@ -133,16 +133,41 @@ 133 133 **** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 134 134 *** Enable/Disable 135 135 ** Pre-loaded with US Federal and common non-Federal US Holidays 136 +** Support for additional algorithms available upon request 136 136 137 -=== Supported HardwareFeatures===138 +==== Circadian Rhythm/Dynamic White ==== 138 138 140 +* Global system CCT Level 141 +* Override CCT per area by scene or manually 142 +* Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 143 +* Time period based 144 +** Time References for start and end of period 145 +*** AM/PM 146 +*** Relative to 147 +**** Sunrise 148 +**** Sunset 149 +**** Solar Noon 150 +** Each time period can have the following setting for CCT 151 +*** Static 152 +*** Linear change over time 153 +*** Sensor with configured CCT when sensor is out of range 154 +* Supported with 0-10V, DMX, and DALI. Additional support via APIs 155 + 156 +==== Supported Hardware Features ==== 157 + 158 +Virtually the entire Crestron lighting product line is supported along with several 3rd party products 159 + 139 139 * Common Settings to all devices 140 140 ** Contractor Label 141 141 ** Name 142 142 ** GlobalId 143 143 ** UniqueId (GUID) 165 +* HVAC 166 +** Temperature control by area 167 +** Support for some Crestron Thermostats, more can be added as needed 168 +** Support for some 3rd party systems, more can be added as needed 144 144 * Keypads 145 -** Support for common fixed configurations, user assignable at runtime 170 +** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types. 146 146 ** Custom keypads with configurable actions per button at runtime 147 147 *** Graphic based programming using showrunner™ HUB UI 148 148 *** Master raise/lower button support allows assignment of currently selected load/shade/area/etc ... ... @@ -160,7 +160,7 @@ 160 160 ** Configurable double tap time support if supported by hardware 161 161 ** Simulate keypads from showrunner™ HUB UI or console 162 162 ** Direct load mapping for some common keypads 163 -* Keyswitch andContact Closure Inputs188 +* Keyswitch/Contact Closure Inputs 164 164 ** Supports all versiport and digital inputs 165 165 ** Maintained and Momentary supported 166 166 ** Feedback output supported ... ... @@ -174,23 +174,42 @@ 174 174 ** 3rd Party and Non-System occupancy sensor support 175 175 ** Occupancy/Vacancy/Disabled/Use Hardware Logic modes, user configurable 176 176 ** Configure scenes recalled by area for occupancy and vacancy states 177 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance 202 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft) 178 178 ** User configurable assignment of sensor to area(s) and load(s) 179 179 ** Occupancy sensors may feed data to multiple areas and loads 180 180 ** Last occupied and vacant times recorded 206 +* Output Signal 207 +** Logic object capable of triggering additional logic 208 +** Can trigger physical outputs via versiports/IOs 209 +** Supports conditional logic 210 +** Independent actions for active/inactive states 211 +** Configurable delays for active/inactive execution 181 181 * Partition sensors 182 182 ** Support for divisible areas 183 183 ** GLS-PART-CN with adjustable sensitivity 184 184 ** 3rd party sensor support via hardware inputs 185 -** User configurable Auto ,Combined,and Divided216 +** User configurable Auto (use sensor) with manual override for Combined and Divided 186 186 ** Filtering to ignore noisy partition sensors 187 -** Change count and last change recorded 218 +** Change count and last change recorded help troubleshoot 219 +* Photocell 220 +** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 221 +** Configurable coefficient 222 +** Configurable thresholds 223 +** Assignable to individual loads for daylight harvesting 224 +* Serial Interface 225 +** RS-232/422/484 226 +** Configurable Baud Rate and Com settings 227 +** Simple ASCII API for controlling/montioring 228 +** Areas/Loads/Occupancy/Partition/Shades supported 229 +* Shades 230 +** Support for Crestron shades/drapes 231 +** Support for many 3rd party shade and drape systems 188 188 189 189 ==== Energy Efficiency ==== 190 190 191 191 * Demand Response/Load Shedding 192 192 ** Automatic via sensor input 193 -** Manually via keypad237 +** Manually via user input 194 194 * Calculated or Measured Power (Watts) 195 195 * Energy Efficiency visualization on floorplan 196 196 ... ... @@ -207,39 +207,156 @@ 207 207 ** Login via username/password or PIN code 208 208 ** Support for Processor or internal user database 209 209 ** Best practices for password handling 210 -* API Usersusing AWSv4 scheme for authentication per request for maximum security254 +* API using AWSv4 scheme for authentication per request for maximum security 211 211 212 -==== System Settings ====256 +==== System Features ==== 213 213 214 214 * User configurable time zone, location, and current time 215 215 * Addressing and Verification of Cresnet devices by serial number 216 216 * Cresnet Device Serial Number capture 217 217 * Configurable Global Actions with touchpanel trigger 218 -* Remote hardware support from neighbor ShowRunner System: 219 -** Allows a master ShowRunner system to integrate slave processors 220 -** AV Serial Interface 221 -** Loads 222 -** Controllers 223 -** Keypad 224 -** Keyswitches 225 -** Occupancy Sensor (including setup for Cresnet sensors) 226 -** Partition Sensors (including setup for Cresnet sensors) 227 -** Photocells 228 -* Web based reporting directly from the processor allows generation of as built documentation: Cresnet Discovery, Device Status, Event Schedule, Keypad Schedule, Load Schedule, and Panel Schedule 262 +* Extensive console command interface (CLI) 229 229 264 +Event Log / Auditing 265 + 266 +* Central logging mechanism 267 +* Messages time stamped 268 +* CSV format 269 +* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace 270 +* Filter by logging level 271 +* Filter by source object 272 +* Filter by GlobalId 273 +* Trace option allows tracking the triggering event through execution 274 +* Thread option allows tracking of the thread executing 275 +* Logging to console 276 +* Logging to file 277 +* Logging to remote syslog (via processor) 278 +* Heartbeat option with configurable interval 279 +* Debugging writes to the event log 280 +* Global Enable flag 281 + 282 +==== Extensibility ==== 283 + 284 +* Actions 285 +** Logic objects exist on showrunner™ objects 286 +** Functionality can be triggered via APIs 287 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within showrunner™ 288 +* Extensions 289 +** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem 290 +** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 291 +* Global Actions 292 +** Allow minimal or input triggered operations against the system 293 +** Can be custom programmed at runtime 294 + 295 +==== User Interfaces ==== 296 + 297 +* showrunner™ HUB 298 +** Web based 299 +** Runs directly on the processor or VC-4 instance 300 +** HTTPS required 301 +** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience 302 +** Node Tree 303 +*** Organize areas in logical locations based on physical topology 304 +*** Searchable, only shows matching areas 305 +** Floorplans 306 +*** Assigned to a node, multiple floor plans are supported 307 +*** Pinch zoom/touch pan 308 +*** User provided floorplan 309 +*** Draw directly on floorplan for areas and objects 310 +**** Areas 311 +**** Loads 312 +**** Partitions 313 +**** Occupancy Sensors 314 +**** Keypads 315 +**** Photocells 316 +*** Crestron product line icons area available to match the installed sensor 317 +*** Interactive control screens depending on clicked object 318 +*** Multiple different views help visualize data 319 +**** Area View - Shows areas with user selected colors 320 +**** Tags View - Shows areas based on their assigned tag 321 +**** Occupancy View - Shows areas based on their current occupancy status and how recently that status changed 322 +**** Intensity View - Shows areas shaded based on the current overall light intensity 323 +**** Energy View - Shows areas shaded based on the areas current energy efficiency from efficient to inefficient 324 +*** Automatic navigation to area when selected from the node tree 325 +*** Fullscreen view 326 +** Schedule 327 +*** See [[Scheduling Features>>doc:||anchor="Scheduling Features"]] for more info 328 +** Reports 329 +*** Interactive data 330 +**** Area Loads 331 +**** Area Scenes 332 +**** Areas 333 +**** Cresnet (Query) 334 +**** Device Status 335 +**** Events 336 +**** Keypads 337 +** Setup 338 +*** Device Diagnostic - Show Diagnostic data from supported devices 339 +*** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 340 +*** File Management - Manage config, license, currently active config, and backup/restore operations 341 +*** Global Actions - Add/Delete/Configure 342 +*** Integrations - Manage integrations with other showrunner™ systems 343 +*** Keypad Configuration - Configure keypads 344 +*** Maps - Add floorplan images 345 +*** Network - DHCP Server (for processors without routers only) 346 +*** System Settings - Manage various system settings 347 +*** Tags - Manage tags and association of tags with areas 348 +*** User Management - Manage users/groups/API users 349 +* Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 350 + 230 230 === Integrations === 231 231 232 232 * AV Integration protocol via serial port 233 -* BACNET Support for integration of Areas, Loads (Licensed Feature) 354 +* BACNnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron) 355 +** Global 356 +*** Override 357 +*** Demand Response 358 +*** Device Offline Count 359 +*** Alarm 360 +*** System Normal/After Hours 361 +** Area Specific 362 +*** showrunner™ Mode 363 +**** Occupancy Status 364 +**** Occupancy Enable 365 +**** Scenes 366 +**** Loads 367 +**** Photocell Level 368 +**** Overall Intensity 369 +**** Power (watts) 370 +*** Zum Hub Emulation Mode 371 +**** Online 372 +**** On 373 +**** Scenes 374 +**** Occupied 375 +**** Occupancy Sensor Enable 234 234 * Crestron Fusion (Licensed Feature) 377 +** Scenes, Recall and Save 378 +** Load Control 379 +** Occupancy Status 380 +** Photocell 235 235 * E-DMX Receiver 236 -** SACN or Art-Net 237 -** Enable/Disable control for loads 382 +** SACN and/or Art-Net 383 +** Enable/Disable control for loads using e-DMX channel value 238 238 ** Map DMX to showrunner loads 239 239 * EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 386 +** Configurable IP address and IP-ID, change at runtime 387 +** Configurable rooms to export, change at runtime 388 +** Changes generate new RSD file at runtime that may be provided to the AV programmer 240 240 * HTTP REST API w/ Authorization 241 241 * Lightweight API provides real-time control/feedback of hardware using CoAP 391 +* TCP Interface using simple ASCII commands, subscriptions supported 392 +* UDP Receiver using simple ASCII commands 242 242 * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature) 394 +* Remote hardware support from neighbor ShowRunner System: 395 +** Allows a central ShowRunner system to integrate edge processors 396 +** AV Serial Interface 397 +** Loads 398 +** Controllers 399 +** Keypad 400 +** Keyswitches 401 +** Occupancy Sensor (including setup for Cresnet sensors) 402 +** Partition Sensors (including setup for Cresnet sensors) 403 +** Photocells 243 243 244 244 === Reporting === 245 245