From version < 5.2 >
edited by Mark Kohlmann
on 2022/10/16 17:23
To version < 6.1 >
edited by Mark Kohlmann
on 2022/10/17 17:48
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,22 @@
1 -showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.
1 +showrunner™ is a commercial lighting control and lighting management system.  showrunner™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.  This documents is not a complete feature list and Chief Integrations reserves the right to make modifications at any time.
2 2  
3 +{{box cssClass="floatinginfobox"}}
4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %)
5 +**CONTENTS**
6 +
7 +{{toc start="4"/}}
8 +{{/box}}
9 +
10 +==== Key Capabilities ====
11 +
12 +* Configuration driven with runtime configuration support enables rapid commissioning of commercial lighting systems
13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements
14 +* Large native hardware support with the option to extend support to new hardware quickly and easily
15 +* Touchpanel and web based UIs cover users needs
16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers
17 +* Floorplans with pinch, zoom, and insight!
18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes
19 +
3 3  ==== Area Features ====
4 4  
5 5  * Lighting Loads
... ... @@ -194,6 +194,7 @@
194 194  *** Scene Recall for Active and Inactive States
195 195  *** Demand Response
196 196  *** Actions for Active and Inactive States
214 +** Commonly used for FACP, override, demand response, and panic inputs
197 197  * Occupancy Sensors:
198 198  ** Occupancy configuration for CN and ZUMLINK occupancy sensors
199 199  ** ​3rd Party and Non-System occupancy sensor support
... ... @@ -222,13 +222,25 @@
222 222  ** Configurable thresholds
223 223  ** Assignable to individual loads for daylight harvesting
224 224  * Serial Interface
225 -** RS-232/422/484
243 +** RS-232/422/484 depending on hardware
226 226  ** Configurable Baud Rate and Com settings
227 -** Simple ASCII API for controlling/montioring
245 +** Simple ASCII API for controlling/monitoring
228 228  ** Areas/Loads/Occupancy/Partition/Shades supported
229 229  * Shades
230 230  ** Support for Crestron shades/drapes
231 231  ** Support for many 3rd party shade and drape systems
250 +* Zum Wired
251 +** Edge logic operation in Zum App mode
252 +*** Override occupancy logic and use showrunner™ logic
253 +** Central logic in CNET mode
254 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes
255 +* Zum Wireless
256 +** Override keypad buttons (except buttons 5-6)
257 +** Edge logic operation
258 +** Override occupancy behavior with showrunner™ logic
259 +** Direct load control
260 +** Scene save
261 +* Support for configuring hardware symbol properties on Crestron hardware
232 232  
233 233  ==== Energy Efficiency ====
234 234  
... ... @@ -249,20 +249,36 @@
249 249  ** HTTPS enforced
250 250  ** Auto session timeout
251 251  ** Login via username/password or PIN code
252 -** Support for Processor or internal user database
282 +** Support for Processor and internal user database with configurable priority or specify one exclusively
253 253  ** Best practices for password handling
254 254  * API using AWSv4 scheme for authentication per request for maximum security
285 +* Encrypted storage of all credentials and keys
255 255  
256 -==== System Features ====
287 +==== General Features ====
257 257  
258 258  * User configurable time zone, location, and current time
259 259  * Addressing and Verification of Cresnet devices by serial number
260 260  * Cresnet Device Serial Number capture
261 -* Configurable Global Actions with touchpanel trigger
262 262  * Extensive console command interface (CLI)
293 +* Simulate sensor and keypad inputs to test without hardware
294 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 
295 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only.
263 263  
264 -Event Log / Auditing
297 +==== Diagnostics ====
265 265  
299 +* Provides diagnostic data when supported by hardware
300 +* Diagnostics available from load controllers all the way up to Cresnet bridges
301 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only
302 +
303 +==== Discovery ====
304 +
305 +* Discover and automatically define Zum Wired hardware
306 +* Discover and automatically define Zum Wireless hardware
307 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number
308 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming
309 +
310 +==== Event Log ====
311 +
266 266  * Central logging mechanism
267 267  * Messages time stamped
268 268  * CSV format
... ... @@ -289,13 +289,13 @@
289 289  ** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem
290 290  ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]]
291 291  * Global Actions
292 -** Allow minimal or input triggered operations against the system
338 +** Allow manual or input triggered operations against the system
293 293  ** Can be custom programmed at runtime
294 294  
295 295  ==== User Interfaces ====
296 296  
297 297  * showrunner™ HUB
298 -** Web based
344 +** Web based, touch and mouse friendly design
299 299  ** Runs directly on the processor or VC-4 instance
300 300  ** HTTPS required
301 301  ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience
... ... @@ -347,11 +347,49 @@
347 347  *** Tags - Manage tags and association of tags with areas
348 348  *** User Management - Manage users/groups/API users
349 349  * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android)
396 +** Area Control Screen
397 +*** Select Area (Can be disabled or restricted)
398 +*** Divide/Combine status, if divisible
399 +*** Occupancy/vacancy status, if has an occupancy sensor
400 +*** Individual load controls
401 +*** Dynamic white color temperature control, if supported
402 +*** RGB color picker, if load supported
403 +*** Scenes, up to 20, save with press and hold
404 +*** Master Raise/Lower
405 +*** Global Actions, if defined, can be hidden
406 +*** HVAC controls, if supported
407 +*** Shade controls, if supported
408 +*** Passcode protected, if enabled
409 +** Setup Screen
410 +*** Passcode protected, if enabled
411 +*** Area Configuration
412 +**** Area List
413 +**** Area Name, editable
414 +**** Load Configuration - Configure load control type and labeling, test fixture operation
415 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings
416 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene
417 +**** Scene Setup - Configure and add/delete scenes
418 +**** Properties - Configure area behavior settings
419 +**** Add/Delete areas
420 +*** Area Layout - Configure partition sensors and area assignments to partition sensors
421 +*** Crestron Integration - Configure EISCs
422 +*** Device Addressing - Address and verify Cresnet devices
423 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status
424 +*** Load Hardware - Configure loads and load controllers
425 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone
426 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas
427 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events)
428 +*** Security Settings - Enable/Disable/Change PIN codes
429 +*** Zum Integration - Configure export to Zum Floor Hub
430 +*** Help Screen - Support contact information, showrunner version list, and license status
431 +** Custom Logo option for splash screen
432 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only
433 +** Optional partition control on floor plan screen
350 350  
351 351  === Integrations ===
352 352  
353 -* AV Integration protocol via serial port
354 -* BACNnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
437 +* AV Integration protocol via serial port, simple ASCII protocol with feedback
438 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
355 355  ** Global
356 356  *** Override
357 357  *** Demand Response
... ... @@ -373,12 +373,12 @@
373 373  **** Scenes
374 374  **** Occupied
375 375  **** Occupancy Sensor Enable
376 -* Crestron Fusion (Licensed Feature)
460 +* Crestron Fusion EM (Licensed Feature)
377 377  ** Scenes, Recall and Save
378 378  ** Load Control
379 379  ** Occupancy Status
380 380  ** Photocell
381 -* E-DMX Receiver
465 +* e-DMX Receiver
382 382  ** SACN and/or Art-Net
383 383  ** Enable/Disable control for loads using e-DMX channel value
384 384  ** Map DMX to showrunner loads
... ... @@ -387,7 +387,7 @@
387 387  ** Configurable rooms to export, change at runtime
388 388  ** Changes generate new RSD file at runtime that may be provided to the AV programmer
389 389  * HTTP REST API w/ Authorization
390 -* Lightweight API provides real-time control/feedback of hardware using CoAP
474 +* Lightweight API provides real-time control/feedback using CoAP
391 391  * TCP Interface using simple ASCII commands, subscriptions supported
392 392  * UDP Receiver using simple ASCII commands
393 393  * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)
... ... @@ -402,7 +402,7 @@
402 402  ** Partition Sensors (including setup for Cresnet sensors)
403 403  ** Photocells
404 404  
405 -=== Reporting ===
489 +==== Reporting ====
406 406  
407 407  ShowRunner provides a website via the processor's internal webserver with the following reports.  All data is live at the time of the generation of the report.
408 408