Changes for page Zummesh Dynamic White/CCT
Last modified by Austin Weygandt on 2025/10/09 15:46
From version 11.1
edited by Austin Weygandt
on 2025/10/09 15:46
on 2025/10/09 15:46
Change comment:
There is no comment for this version
To version 1.2
edited by Mark Kohlmann
on 2021/09/07 17:42
on 2021/09/07 17:42
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ SetupGuide.TroubleshootingGuide.Advanced Tools.WebHome1 +SHOWRUNNER™ User Guide & Wiki.Troubleshooting.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a ustin\.weygandt@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,37 +1,13 @@ 1 -{{warning}} 2 -Caveats: 1 +Zum wireless supports dynamic white using DALI Groups 9-16. Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunner requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunner will be ignored. 3 3 3 +==== Caveats: ==== 4 + 4 4 * Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 -* NETBRIDGE must be attached to the ZUMMESH-J BOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed.6 -* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes)6 +* NETBRIDGE must be attached to the ZUMMESH-JOBX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 7 +* Supports up to 8 CCT channels, DALI Groups 9-16 7 7 * Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 8 * Setup must be done from the gateway console 9 -* Loads must be manually changed to BusIndex 3 in the config 10 -{{/warning}} 11 11 12 -Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 13 - 14 -==== Typical Setup for up to 6 zones, 5 fixture types: ==== 15 - 16 -(% border="1" style="width:600px" %) 17 -|=DALI Group|=Name|=Fixture Type|=Control Type 18 -|0|Downlights, Main|F0|Intensity 19 -|1|Downlights, Main/Screen CCT|F0|Color 20 -|2|Accent Lights|F1a|Intensity 21 -|3|Accent Lights CCT|F1a|Color 22 -|4|Spot Lights|F3|Intensity 23 -|5|Spot Lights CCT|F3|Color 24 -|6|Troffers|F4c|Intensity 25 -|7|Troffers CCT|F4c|Color 26 -|8|Linear|F9|Intensity 27 -|9|Linear|F9|Color 28 -|10|Downlights @ Screen|F0|Intensity 29 -|11|-|-|Color 30 -|12|-|-|Intensity 31 -|13|-|-|Color 32 -|14|-|-|Intensity 33 -|15|-|-|Color 34 - 35 35 ==== Setup Steps: ==== 36 36 37 37 1. Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android. ... ... @@ -38,23 +38,9 @@ 38 38 Command: //rfrcon <**NetbridgeID**> DALIGLOBALADDRESS <**Action**>// 39 39 **Action**: 0=stop, 1=start, 3=get status 40 40 Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGLOBALADDRESS 1// 41 -1. Create DALI Groups. If group already exists then go to step 3.This must be done from the gateway console.17 +1. Create DALI Groups. This must be done from the gateway console. 42 42 Command: //rfrcon <**NetbridgeID**> DALIGROUPADDDELETE <**GroupID**> <**Operation**> <**GroupName**>// 43 43 **GroupID: **0 to 15 44 44 **Operation:** 0=Delete Group, 1=Add Intensity Group, 3=Add Color Group 45 -**GroupName: **Name of the group, no spaces, 16 characters max 46 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPADDDELETE 8 3 TypeF1-Color// 47 -1. Modify DALI Group to color, only needed if step 2 was not done. If step 2 was performed skip this step. 48 -Command: //rfrcon <**NetbridgeID**> DALIGROUPSETTWRITE <**GroupID**> 14 <**GroupType**>// 49 -**GroupID: **0 to 15 50 -**GroupType:** 0=Intensity, 1=Color 51 -Example: (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 8 14 1// 52 -1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. 53 -Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 54 -**GroupID**: 0 to 15 (odd for color) 55 -**SceneID**: Scene number (1 to 16) 56 -**SceneLevel**: 255 for ShowRunner control, 0-254 for fixed scene level 57 -**Action**: 0=Remove Scene, 1=Add Scene 58 -**FadeTime**: Fade time in 1/10th of a second 59 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 8 1 255 1 10// 60 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 15 1 255 1 10// 21 +**GroupName: **Name of the group, no spaces 22 +1.