Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 9.1
edited by Alexander Mott
on 2022/06/16 20:40
on 2022/06/16 20:40
Change comment:
There is no comment for this version
To version 10.7
edited by Alexander Mott
on 2022/06/17 16:56
on 2022/06/17 16:56
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Z UMNET-JBOXSetup1 +Zūm Net Device Setup - Content
-
... ... @@ -21,10 +21,38 @@ 21 21 1. Identifying which DHCP assigned IP address corresponds to each ZUMNET-JBOX 22 22 1. Connecting to each ZUMNET-JBOX and assigning a permanent static IP address and IP-ID 23 23 24 -==== Identifying Z ūmNet Devices ====24 +==== Identifying ZUMNET-JBOXs ==== 25 25 26 26 Once all ZUMNET-JBOXs have been assigned temporary IP addresses from the DHCP server, they must each be identified so that the correct IP-ID can be assigned. The goal is to associate each assigned IP address with the room that each ZUMNET-JBOX is meant to control. Then we can connect to each ZUMNET-JBOX and set static IP addresses and update the IP table with the correct IP-ID. 27 27 28 +There are three primary ways of identifying ZUMNET-JBOXs: 29 + 30 +1. Identifying by hostname 31 +1. Identifying by serial number or MAC address 32 +1. Identifying through Device Tree View 33 + 34 +Each of these methods involves generating a Device Summary using the Device Discovery Tool in Toolbox. The Device Summary is a file which lists all devices that are discoverable on the network along with useful information such as their hostname, IP address, and MAC address. 35 + 36 +To generate a Device Summary in Toolbox: 37 + 38 +* Connect to the lighting network and open Device Discovery Tool in Toolbox 39 +* The Device Discovery tool will automatically report how many Ethernet devices have been discovered 40 +* Verify that the expected number of Ethernet devices have been discovered, including any TSWs, GLPACs, DIN-CENCN-2s, etc. 41 +** Note that only Crestron devices will appear in Device Discovery; non-Crestron devices (such as Pharos or Enttec DMX controllers) will not appear in Device Discovery Tool 42 +** If no devices are discovered, verify that your computer is connected to the network and your IP address is compatible with the network 43 +** If some devices are missing, there may be an issue with your DHCP server settings or the network wiring 44 +* Click the "Export..." button below the list of discovered devices 45 +** If this button says "Address Book", then Toolbox needs to be updated 46 +* Click the Write Device Summary button and save the Device Summary to your computer 47 +** Though saved as a text file, the Device Summary is actually a table of comma separated values 48 +** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 49 + 50 +Once the Device Summary has been generated, proceed to identifying each ZUMNET-JBOX using the hostname, SN/MAC, or Device Tree View methods described below. 51 + 52 +===== Identifying by Hostname ===== 53 + 54 +Oftentimes, 55 + 28 28 If the electrical contractor has provided a list of which serial numbers/MAC addresses belong to each installed ZUMNET-JBOX, then it is relatively easy to identify which ZUMNET-JBOX should get which IP-ID: 29 29 30 30 * Connect to the lighting network and open Device Discovery Tool in Toolbox ... ... @@ -57,9 +57,9 @@ 57 57 Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID: 58 58 59 59 * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX 60 -* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0. 20**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%))88 +* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%)) 61 61 ** Disable DHCP: ##dhcp off## 62 -** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0. 20**(%%)##90 +** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)## 63 63 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 64 64 ** Set default gateway: ##defr 0 **10.0.0.1**## 65 65 ** Update IP table: ##addm (% style="color:olive" %)**30**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## ... ... @@ -69,14 +69,12 @@ 69 69 70 70 === Zūm Net Specific Configuration === 71 71 72 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. 100 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in Zūm Mode from the factory, and this is typically the desired setting. 73 73 74 74 ==== Zūm/Cresnet Mode ==== 75 75 76 -Z UMNET-JBOXsshould shipin"ZūmMode"bydefault,alsoknown as"AppMode"because this is thesetting required to be able toconfigure ZūmWired rooms using theCrestronZūm MobileApp.104 +Zūm Mode (also known as App Mode) is the default setting for new ZUMNET-JBOXs, and allows them to be configured from the Crestron Zūm App. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled. Generally, Cresnet mode is only required if non-Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads) or if certain SHOWRUNNER™ features are required (such as changing the dimming response curve). 77 77 78 -If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the App and all internal logic will be disabled. Generally, Cresnet mode is only required if non Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads). 79 - 80 80 The commands to view or change the Zūm/Cresnet mode are: 81 81 82 82 * View current mode: ##zwmode## ... ... @@ -87,10 +87,8 @@ 87 87 88 88 ==== Master/Slave Mode ==== 89 89 90 -ZUMNET-JBOXs sh ould ship in "Master" mode by default, and generally this is how they should be configured.116 +ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 91 91 92 -"Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 93 - 94 94 1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 95 95 1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 96 96