Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2025/07/10 21:27
From version 58.1
edited by Alexander Mott
on 2025/07/10 21:27
on 2025/07/10 21:27
Change comment:
There is no comment for this version
To version 54.2
edited by Alexander Mott
on 2025/07/10 21:24
on 2025/07/10 21:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,7 +128,6 @@ 128 128 == Updating Firmware == 129 129 130 130 {{error}} 131 -((( 132 132 Per Crestron's Zūm Wired firmware v4.01.06 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required. 133 133 134 134 Zūm Wired JBOXs operating as the Primary controller in App mode with firmware versions 4.x.x and above are limited in the number of secondary devices that can be supported on the Zūm Link bus: ... ... @@ -136,8 +136,8 @@ 136 136 * ZUMNET-JBOX-DALI : 7 maximum secondary devices 137 137 * ZUMNET-JBOX-~*~** : 14 maximum secondary devices 138 138 * ZUMLINK-JBOX-~*~** : 14 maximum secondary devices 138 + 139 139 These limitations do not apply to JBOXs operating in CNET mode //or// running firmware versions 3.x.x 140 -))) 141 141 {{/error}} 142 142 143 143 It is best practice to upgrade all Zūm Wired devices to the latest version, or at the very least update all devices to the same firmware version across the job. The recommended process for updating Zūm Wired firmware is: ... ... @@ -227,12 +227,10 @@ 227 227 228 228 === Zūm Mode Auto Switch === 229 229 230 -{{error}} 231 -ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must not have Auto Switch enabled. Doing so will result in unintended behavior, including improper app mode functionality and excessive rebooting once reconnected to the processor. 229 +{{error}}ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must not have Auto Switch enabled. Doing so will result in unintended behavior, including improper app mode functionality and excessive rebooting once reconnected to the processor. 232 232 {{/error}} 233 233 234 -{{warning}} 235 -With Auto Switch enabled, ZUMNET-JBOXs may overwrite the ShowRunnerCLC™ scenes upon reconnecting to the processor: disable auto switch or set scenes both in the App and in ShowRunnerCLC™ to avoid this issue 232 +{{warning}}With Auto Switch enabled, ZUMNET-JBOXs may overwrite the ShowRunnerCLC™ scenes upon reconnecting to the processor: disable auto switch or set scenes both in the App and in ShowRunnerCLC™ to avoid this issue 236 236 {{/warning}} 237 237 238 238 Zūm Mode Auto Switch is a feature introduced by Crestron in November of 2022 with .puf firmware v1.04.05 (device firmware 1.004.00005). This feature is intended to address concerns that arose from projects using custom programs with ZUMNET-JBOX-* devices in CNET Mode. Previously, if a device in CNET Mode lost connection to the processor, then it would be impossible to maintain any sort of control over the lighting. With Zūm Mode Auto Switch enabled, a ZUMNET-JBOX running in CNET Mode will automatically switch to App Mode and process local logic in the event that it loses connection to the processor.