Changes for page Zūm Net Device Setup

Last modified by Alexander Mott on 2025/07/10 21:27

From version 58.1
edited by Alexander Mott
on 2025/07/10 21:27
Change comment: There is no comment for this version
To version 53.1
edited by Alexander Mott
on 2025/06/04 21:12
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,8 @@
1 -{{warning}}
1 +(% class="box warningmessage" %)
2 +(((
2 2  This article is for configuring Zūm Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].
3 3  For details on using the Zūm Discovery feature to automatically build a ShowRunnerCLC™ configuration based on the Zūm App settings, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome]].
4 -{{/warning}}
5 +)))
5 5  
6 6  {{box cssClass="floatinginfobox" title="**CONTENTS**"}}
7 7  {{toc/}}
... ... @@ -127,7 +127,7 @@
127 127  
128 128  == Updating Firmware ==
129 129  
130 -{{error}}
131 +(% class="box errormessage" %)
131 131  (((
132 132  Per Crestron's Zūm Wired firmware v4.01.06 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required.
133 133  
... ... @@ -136,9 +136,9 @@
136 136  * ZUMNET-JBOX-DALI : 7 maximum secondary devices
137 137  * ZUMNET-JBOX-~*~** : 14 maximum secondary devices
138 138  * ZUMLINK-JBOX-~*~** : 14 maximum secondary devices
140 +
139 139  These limitations do not apply to JBOXs operating in CNET mode //or// running firmware versions 3.x.x
140 140  )))
141 -{{/error}}
142 142  
143 143  It is best practice to upgrade all Zūm Wired devices to the latest version, or at the very least update all devices to the same firmware version across the job. The recommended process for updating Zūm Wired firmware is:
144 144  
... ... @@ -160,10 +160,11 @@
160 160  
161 161  == Primary/Secondary Mode ==
162 162  
163 -{{warning}}
164 +(% class="box warningmessage" %)
165 +(((
164 164  Zūm Wired firmware v1.03.27 (device firmware v1.002.00026) updates the terminology from "master"/"slave" to "primary"/"secondary", and changes the ##zwms## command to ##zwps##
165 165  Devices running this newer firmware will not accept commands using "master"/"slave" as arguments.
166 -{{/warning}}
168 +)))
167 167  
168 168  ZUMNET-JBOXs can be in either "Primary" or "Secondary" mode. In most situations, "Primary" is the desired mode of operations, as "Secondary" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX and prevents it from discovering devices on the Zūm Link bus or performing any logic. There are two scenarios in which a ZUMNET-JBOX should be configured in "Secondary" mode:
169 169  
... ... @@ -186,10 +186,6 @@
186 186  
187 187  == Zūm/Cresnet Mode ==
188 188  
189 -{{error}}
190 -ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must be kept in CNET mode and not be allowed into Zūm Mode.
191 -{{/error}}
192 -
193 193  Zūm Mode (also known as App Mode) is the default setting for ZUMNET-JBOXs shipping on newer firmware, and allows them to be configured from the Crestron Zūm App as long as a ZUMLINK-KP is connected to the JBOX. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled.
194 194  
195 195  Generally, ZUMNET-JBOXs do not need to be in Cresnet mode to work with ShowRunnerCLC™ except in specific cases:
... ... @@ -227,10 +227,6 @@
227 227  
228 228  === Zūm Mode Auto Switch ===
229 229  
230 -{{error}}
231 -ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must not have Auto Switch enabled. Doing so will result in unintended behavior, including improper app mode functionality and excessive rebooting once reconnected to the processor.
232 -{{/error}}
233 -
234 234  {{warning}}
235 235  With Auto Switch enabled, ZUMNET-JBOXs may overwrite the ShowRunnerCLC™ scenes upon reconnecting to the processor: disable auto switch or set scenes both in the App and in ShowRunnerCLC™ to avoid this issue
236 236  {{/warning}}