... ... @@ -128,27 +128,15 @@
128 128  == Updating Firmware ==
129 129  
130 130  {{error}}
131 -(((
132 132  Per Crestron's Zūm Wired firmware v4.01.06 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required.
133 -)))
134 134  
135 -(((
136 136  Zūm Wired JBOXs operating as the Primary controller in App mode with firmware versions 4.x.x and above are limited in the number of secondary devices that can be supported on the Zūm Link bus:
137 -)))
138 138  
139 -* (((
140 -ZUMNET-JBOX-DALI : 7 maximum secondary devices
141 -)))
142 -* (((
143 -ZUMNET-JBOX-~*~** : 14 maximum secondary devices
144 -)))
145 -* (((
146 -ZUMLINK-JBOX-~*~** : 14 maximum secondary devices
147 -)))
135 +* ZUMNET-JBOX-DALI : 7 maximum secondary devices
136 +* ZUMNET-JBOX-~*~** : 14 maximum secondary devices
137 +* ZUMLINK-JBOX-~*~** : 14 maximum secondary devices
148 148  
149 -(((
150 150  These limitations do not apply to JBOXs operating in CNET mode //or// running firmware versions 3.x.x
151 -)))
152 152  {{/error}}
153 153  
154 154  It is best practice to upgrade all Zūm Wired devices to the latest version, or at the very least update all devices to the same firmware version across the job. The recommended process for updating Zūm Wired firmware is:
... ... @@ -197,9 +197,9 @@
197 197  
198 198  == Zūm/Cresnet Mode ==
199 199  
200 -{{error}}
188 +{{warning}}
201 201  ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must be kept in CNET mode and not be allowed into Zūm Mode.
202 -{{/error}}
190 +{{/warning}}
203 203  
204 204  Zūm Mode (also known as App Mode) is the default setting for ZUMNET-JBOXs shipping on newer firmware, and allows them to be configured from the Crestron Zūm App as long as a ZUMLINK-KP is connected to the JBOX. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled.
205 205  
... ... @@ -241,7 +241,6 @@
241 241  {{error}}
242 242  ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must not have Auto Switch enabled. Doing so will result in unintended behavior, including improper app mode functionality and excessive rebooting once reconnected to the processor.
243 243  {{/error}}
244 -
245 245  {{warning}}
246 246  With Auto Switch enabled, ZUMNET-JBOXs may overwrite the ShowRunnerCLC™ scenes upon reconnecting to the processor: disable auto switch or set scenes both in the App and in ShowRunnerCLC™ to avoid this issue
247 247  {{/warning}}