Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2025/07/10 21:27
From version 56.1
edited by Alexander Mott
on 2025/07/10 21:25
on 2025/07/10 21:25
Change comment:
There is no comment for this version
To version 58.1
edited by Alexander Mott
on 2025/07/10 21:27
on 2025/07/10 21:27
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,6 +128,7 @@ 128 128 == Updating Firmware == 129 129 130 130 {{error}} 131 +((( 131 131 Per Crestron's Zūm Wired firmware v4.01.06 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required. 132 132 133 133 Zūm Wired JBOXs operating as the Primary controller in App mode with firmware versions 4.x.x and above are limited in the number of secondary devices that can be supported on the Zūm Link bus: ... ... @@ -135,8 +135,8 @@ 135 135 * ZUMNET-JBOX-DALI : 7 maximum secondary devices 136 136 * ZUMNET-JBOX-~*~** : 14 maximum secondary devices 137 137 * ZUMLINK-JBOX-~*~** : 14 maximum secondary devices 138 - 139 139 These limitations do not apply to JBOXs operating in CNET mode //or// running firmware versions 3.x.x 140 +))) 140 140 {{/error}} 141 141 142 142 It is best practice to upgrade all Zūm Wired devices to the latest version, or at the very least update all devices to the same firmware version across the job. The recommended process for updating Zūm Wired firmware is: