Changes for page Zūm Net Device Setup

Last modified by Alexander Mott on 2025/07/10 21:27

From version 53.1
edited by Alexander Mott
on 2025/06/04 21:12
Change comment: There is no comment for this version
To version 55.1
edited by Alexander Mott
on 2025/07/10 21:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,8 +1,7 @@
1 -(% class="box warningmessage" %)
2 -(((
1 +{{warning}}
3 3  This article is for configuring Zūm Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].
4 4  For details on using the Zūm Discovery feature to automatically build a ShowRunnerCLC™ configuration based on the Zūm App settings, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome]].
5 -)))
4 +{{/warning}}
6 6  
7 7  {{box cssClass="floatinginfobox" title="**CONTENTS**"}}
8 8  {{toc/}}
... ... @@ -128,8 +128,7 @@
128 128  
129 129  == Updating Firmware ==
130 130  
131 -(% class="box errormessage" %)
132 -(((
130 +{{error}}
133 133  Per Crestron's Zūm Wired firmware v4.01.06 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required.
134 134  
135 135  Zūm Wired JBOXs operating as the Primary controller in App mode with firmware versions 4.x.x and above are limited in the number of secondary devices that can be supported on the Zūm Link bus:
... ... @@ -139,7 +139,7 @@
139 139  * ZUMLINK-JBOX-~*~** : 14 maximum secondary devices
140 140  
141 141  These limitations do not apply to JBOXs operating in CNET mode //or// running firmware versions 3.x.x
142 -)))
140 +{{/error}}
143 143  
144 144  It is best practice to upgrade all Zūm Wired devices to the latest version, or at the very least update all devices to the same firmware version across the job. The recommended process for updating Zūm Wired firmware is:
145 145  
... ... @@ -161,11 +161,10 @@
161 161  
162 162  == Primary/Secondary Mode ==
163 163  
164 -(% class="box warningmessage" %)
165 -(((
162 +{{warning}}
166 166  Zūm Wired firmware v1.03.27 (device firmware v1.002.00026) updates the terminology from "master"/"slave" to "primary"/"secondary", and changes the ##zwms## command to ##zwps##
167 167  Devices running this newer firmware will not accept commands using "master"/"slave" as arguments.
168 -)))
165 +{{/warning}}
169 169  
170 170  ZUMNET-JBOXs can be in either "Primary" or "Secondary" mode. In most situations, "Primary" is the desired mode of operations, as "Secondary" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX and prevents it from discovering devices on the Zūm Link bus or performing any logic. There are two scenarios in which a ZUMNET-JBOX should be configured in "Secondary" mode:
171 171  
... ... @@ -188,6 +188,10 @@
188 188  
189 189  == Zūm/Cresnet Mode ==
190 190  
188 +{{error}}
189 +ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must be kept in CNET mode and not be allowed into Zūm Mode.
190 +{{/error}}
191 +
191 191  Zūm Mode (also known as App Mode) is the default setting for ZUMNET-JBOXs shipping on newer firmware, and allows them to be configured from the Crestron Zūm App as long as a ZUMLINK-KP is connected to the JBOX. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled.
192 192  
193 193  Generally, ZUMNET-JBOXs do not need to be in Cresnet mode to work with ShowRunnerCLC™ except in specific cases:
... ... @@ -225,6 +225,10 @@
225 225  
226 226  === Zūm Mode Auto Switch ===
227 227  
229 +{{error}}
230 +ZUMNET-JBOXs on firmware 4.x.x and above that exceed the maximum allowable ZUMLINK device count must not have Auto Switch enabled. Doing so will result in unintended behavior, including improper app mode functionality and excessive rebooting once reconnected to the processor.
231 +{{/error}}
232 +
228 228  {{warning}}
229 229  With Auto Switch enabled, ZUMNET-JBOXs may overwrite the ShowRunnerCLC™ scenes upon reconnecting to the processor: disable auto switch or set scenes both in the App and in ShowRunnerCLC™ to avoid this issue
230 230  {{/warning}}