Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
To version 50.2
edited by Alexander Mott
on 2024/10/15 14:14
on 2024/10/15 14:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -133,18 +133,13 @@ 133 133 Per Crestron's Zūm Wired firmware v4.01.06.02 release notes, devices running firmware v3.09.05 or earlier "are not supported for upgrade via the Zum App / Hub / or Toolbox" and users should contact Crestron True Blue Support for upgrade paths when required. 134 134 ))) 135 135 136 - It is bestpractice to upgradeall Zūm Wireddevicesto the latest version,oratthe veryleast update all devices tothe same firmwareversionacross thejob. The recommended process for updating Zūm Wired firmware is:136 +Updating firmware to the latest version is strongly recommended. The recommended process for updating Zūm Wired firmware is: 137 137 138 138 1. Ensure that the ZUMNET-JBOX for the room is in Primary / Zūm Mode (see below) so that it will re-address all connected Zūm Link devices 139 -1. Connect to the ZUMNET-JBOX in Network Device Tree View andverify that all expected Zūm Link devices are online and that there are no conflicting/duplicate IDs139 +1. Connect to the ZUMNET-JBOX in Network Device Tree View to verify that all expected Zūm Link devices are online and that there are no conflicting or duplicate IDs 140 140 1*. We have run into issues where devices will not always be uniquely addressed, typically as a result of cabling termination issues (incorrect pin-out or use of "EZ RJ45" passthrough connectors) 141 -1*. Occasionally, ZUMLINK-KP will be stuck at ID 03 after the ZUMNET-JBOX has been put into Primary/App Mode - in these cases, briefly disconnecting the keypad, reconnecting it, and waiting a few minutes will allow the keypad's address to be changed 142 -1. Use the Zūm Wired .puf file or the Firmware Updating Script tool built into ShowRunner™ to update all the ZUMNET-JBOXs 143 -1*. Note that as part of the update process, the ZUMNET-JBOX will reboot, which will cycle the connected load and briefly interrupt Ethernet connection to any downstream ZUMNET-JBOXs or other Ethernet devices, which in rare instances will cause the firmware update to fail 144 -1. Verify that all the ZUMNET-JBOXs have successfully updated by using the Device Discovery Tool device export and checking the reported firmware version 145 -1. If any ZUMNET-JBOXs failed to update, try to update it again in case the update failure was caused by an upstream device rebooting 146 -1. I 147 -1*. ZUMNET-JBOXs will update their firmware only after all connected Zūm Link devices have been successfully updated; verify 141 +1*. Occasionally, ZUMLINK-KP will be stuck at ID 03 after the ZUMNET-JBOX has been put into Primary/App Mode - in these cases, briefly disconnecting the keypad, reconnecting it, and waiting a few minutes will allow the keypad to be re-addressed 142 +1. adsf 148 148 149 149 Alternatively, rooms can be updated through the Crestron Zūm App as of firmware v1.03.54, however only one room can be upgraded at a time and your mobile device will become occupied for the duration of the firmware upgrade (15-45 minutes depending on firmware version and quantity of Zūm Wired devices in the room) 150 150