Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 45.1
edited by Alexander Mott
on 2023/10/06 22:52
on 2023/10/06 22:52
Change comment:
There is no comment for this version
To version 46.1
edited by Alexander Mott
on 2023/10/10 16:31
on 2023/10/10 16:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -178,6 +178,8 @@ 178 178 179 179 Zūm Mode Auto Switch is a feature introduced by Crestron in November of 2022 with .puf firmware v1.04.05 (device firmware 1.004.00005). This feature is intended to address concerns that arose from projects using custom programs with ZUMNET-JBOX-* devices in CNET Mode. Previously, if a device in CNET Mode lost connection to the processor, then it would be impossible to maintain any sort of control over the lighting. With Zūm Mode Auto Switch enabled, a ZUMNET-JBOX running in CNET Mode will automatically switch to App Mode and process local logic in the event that it loses connection to the processor. 180 180 181 +Note that on 0-10V and switched JBOXs, the connected loads will flash once when rebooting. On ZUMNET-DALI-JBOX models, the JBOX will reboot once when switching to App mode and twice when switching back to CNET mode (once to switch to CNET, and a second time to switch to Legacy DALI mode) 182 + 181 181 Enable Zūm Mode Auto Switch using the command: ##autoswitch on## 182 182 183 183 Rebooting after changing Auto Switch modes is not officially required, but is still recommended.