Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 45.1
edited by Alexander Mott
on 2023/10/06 22:52
on 2023/10/06 22:52
Change comment:
There is no comment for this version
To version 37.1
edited by Alexander Mott
on 2022/09/22 23:09
on 2022/09/22 23:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,7 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 3 This article is for configuring Zūm Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 -For details on using the Zūm Discovery feature to automatically build a S howRunnerCLC™ configuration based on the Zūm App settings, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Zūm Discovery.WebHome]].4 +For details on using the Zūm Discovery feature to automatically build a SHOWRUNNER™ configuration based on the Zūm App settings, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Zūm Discovery.WebHome]]. 5 5 ))) 6 6 7 7 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} ... ... @@ -8,9 +8,11 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with ShowRunnerCLC™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. 11 +(% class="row" %) 12 +((( 13 +Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with SHOWRUNNER™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. 12 12 13 -Much like DIN-CENCN-2s in S howRunnerCLC™ installations, ZUMNET-JBOXs identify themselves to the processor via their IP-ID, so the specific IP address of any given ZUMNET-JBOX does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. If hosted devices are moved between ZUMNET-JBOXs, or if the ZUMNET-JBOX needs to have a different IP-ID than it was initially assigned, the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet which will list all the Zūm Net and Zūm Link devices and their associated IP-IDs. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. ZUMNET-JBOX's will typically start with IP-IDs in the 30-5F range, but can potentially exceed this range.15 +Much like DIN-CENCN-2s in SHOWRUNNER™ installations, ZUMNET-JBOXs identify themselves to the processor via their IP-ID, so the specific IP address of any given ZUMNET-JBOX does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. If hosted devices are moved between ZUMNET-JBOXs, or if the ZUMNET-JBOX needs to have a different IP-ID than it was initially assigned, the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet which will list all the Zūm Net and Zūm Link devices and their associated IP-IDs. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. ZUMNET-JBOX's will typically start with IP-IDs in the 30-5F range, but can potentially exceed this range. 14 14 15 15 = Identification and IP Configuration = 16 16 ... ... @@ -19,7 +19,7 @@ 19 19 Since there is no option to configure ZUMNET-JBOXs via USB, a DHCP server is required. There are three options for DHCP servers: 20 20 21 21 * Using a processor with a Control Subnet (only available on certain processors) 22 -* Using the built-in [[S howRunnerCLC™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] (available on all processors running ShowRunnerCLC™ v3.009 or newer)24 +* Using the built-in [[SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] (available on all processors running SHOWRUNNER™ v3.009 or newer) 23 23 * Using third party DHCP server software on your computer 24 24 25 25 Most devices (DIN-CENCN-2, TSW, ZUMNET-JBOXs) rely only on IP-ID to identify themselves to the processor, but some devices (such as GLPACs, DMX controllers, and other processors) have IP addresses that are explicitly defined in the configuration file. The DHCP server should be configured to assign IP addresses that are visible to the processor, but excluded from assigning these explicitly defined IP addresses if possible. ... ... @@ -55,13 +55,18 @@ 55 55 ** Though saved as a text file, the Device Summary is actually a table of comma separated values 56 56 ** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 57 57 58 - See the [[Exportto DeviceSummary>>doc:SHOWRUNNER™SetupGuide.SHOWRUNNER™InstallationGuide.Preparation.ToolboxBasics.WebHome||anchor="HExporttoDeviceSummary"]]section ofthe ToolboxBasicspageformoreetail.60 +Below is an example of a Device Summary for a fully-configured job: 59 59 62 +* DeviceSummary.txt: 63 +[[image:1655487020590-542.png]] 64 +* DeviceSummary.csv: 65 +[[image:1655487132138-904.png]] 66 + 60 60 Once the Device Summary has been generated, proceed to identifying each ZUMNET-JBOX using the hostname, SN/MAC, or Device Tree View methods described below. 61 61 62 62 === Identifying by Hostname === 63 63 64 -The Crestron Zūm App is used to configure the internal logic of Zūm Wired rooms. This internal logic determines the room behavior when ZUMNET-JBOXs are used in standalone applications or if communication to the processor is lost. Even on S howRunnerCLC™howRunnerCLC™ logic in order to minimize disruption to end-users in the event of a processor or network failure.71 +The Crestron Zūm App is used to configure the internal logic of Zūm Wired rooms. This internal logic determines the room behavior when ZUMNET-JBOXs are used in standalone applications or if communication to the processor is lost. Even on SHOWRUNNER™ jobs with a central program running the lighting controls, it is best practice to configure the internal logic to match as closely as possible the SHOWRUNNER™ logic in order to minimize disruption to end-users in the event of a processor or network failure. 65 65 66 66 In addition to configuring default room logic, the Crestron Zūm App can be used to change the hostname of the ZUMNET-JBOX for each room. By default, the hostname for a ZUMNET-JBOX is the model followed by the last six digits of the MAC address, e.g. "ZUMNET-JBOX-16A-LV-F2DA94". If you or the electrical contractor already intend to configure the internal logic each ZUMNET-JBOX, it would be a good idea to also change the hostname to something more identifiable. 67 67 ... ... @@ -106,18 +106,16 @@ 106 106 107 107 == Assigning Permanent Static IP Addresses and IP-IDs == 108 108 109 -Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID .116 +Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID: 110 110 111 -Note that static IP addresses are only required on jobs where there is no permanent DHCP server. Manual IP-ID assignment is not required for jobs intended to be used with Zūm Auto Discovery, though it may still be recommended in order to keep track and document which IP-ID is associated with each area (Auto Discovery will auto-assign IP-IDs to ZUMNET-JBOXs without IP-IDs, but if a ZUMNET-JBOX already has an IP table entry it will be imported to the configuration with that pre-existing IP-ID). 112 - 113 113 * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX 114 114 * Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%); the hostname can be skipped if it has already been configured from the Crestron Zūm App) 120 +** Disable DHCP: ##dhcp off## 115 115 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)## 116 116 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 117 117 ** Set default gateway: ##defr 0 **10.0.0.1**## 118 118 ** Update IP table: ##addm (% style="color:olive" %)**30**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 119 119 ** Set hostname: ##host (% style="color:purple" %)**ZNET-JBOX-RM-201**(%%)## 120 -** Disable DHCP: ##dhcp off## 121 121 ** Reboot the ZUMNET-JBOX: ##reboot## 122 122 *** Note that rebooting the JBOX will cause the lights to briefly cut out 123 123 * Repeat for all ZUMNET-JBOXs on the job ... ... @@ -124,38 +124,11 @@ 124 124 125 125 = Zūm Net Specific Configuration = 126 126 127 -Zūm Net devices have a two additional settings not present for other devices: Primary/Secondary mode andZūm/Cresnet mode.ZUMNET-JBOX-DALI have a third setting forGroup/LegacyDALImode,and allZUMNET-JBOX-*thatarein CNET modeanoptionallybeconfiguredtoautomaticallyswitchbackandforthbetweenCNET and App mode dependingon whetherthecontrol processorisreachable.132 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in Zūm Mode from the factory, and this is typically the desired setting. 128 128 129 -== Primary/Secondary Mode == 130 - 131 -(% class="box warningmessage" %) 132 -((( 133 -Zūm Wired firmware v1.03.27 (device firmware v1.002.00026) updates the terminology from "master"/"slave" to "primary"/"secondary", and changes the ##zwms## command to ##zwps## 134 -Devices running this newer firmware will not accept commands using "master"/"slave" as arguments. 135 -))) 136 - 137 -ZUMNET-JBOXs can be in either "Primary" or "Secondary" mode. In most situations, "Primary" is the desired mode of operations, as "Secondary" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX and prevents it from discovering devices on the Zūm Link bus or performing any logic. There are two scenarios in which a ZUMNET-JBOX should be configured in "Secondary" mode: 138 - 139 -1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 140 -1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 141 - 142 -ZUMNET-JBOXs with firmware 1.006.00012 or newer will ship from the factory in "Primary" mode, but will go to "Secondary" mode if a hardware reset is performed. ZUMNET-JBOXs with older firmware will ship in "Secondary" mode. The commands to view or change the Primary/Secondary mode are: 143 - 144 -* View current mode: 145 -** Current FW: ##zwps## or ##zwmode## 146 -** Old FW: ##zwms## 147 -* Make "Primary": 148 -** Current FW: ##zwps primary## 149 -** Old FW: ##zwms master## 150 -* Make "Secondary": 151 -** Current FW: ##zwps secondary## 152 -** Old FW: ##zwms slave## 153 - 154 -A reboot is required if the mode is changed. 155 - 156 156 == Zūm/Cresnet Mode == 157 157 158 -Zūm Mode (also known as App Mode) is the default setting for new ZUMNET-JBOXs, and allows them to be configured from the Crestron Zūm App. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled. Generally, Cresnet mode is only required if non-Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads) or if certain S howRunnerCLC™ features are required (such as changing the dimming response curve).136 +Zūm Mode (also known as App Mode) is the default setting for new ZUMNET-JBOXs, and allows them to be configured from the Crestron Zūm App. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled. Generally, Cresnet mode is only required if non-Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads) or if certain SHOWRUNNER™ features are required (such as changing the dimming response curve). 159 159 160 160 The commands to view or change the Zūm/Cresnet mode are: 161 161 ... ... @@ -165,27 +165,23 @@ 165 165 166 166 A reboot is required if the mode is to be changed. Note that this command will also display the current Master/Slave mode, but will not allow you to change it. 167 167 168 -== =DALI Group/LegacyMode ===146 +== Master/Slave Mode == 169 169 170 -ZUMNET-JBOX -DALIthat are operatinginAppmodeshouldbekeptin"Groups"DALI mode,and DALI loadsmustbe configuredthroughtheZūmApp.ZUMNET-JBOX-DALIthatare operatinginCNETmodewithShowRunner™ must bechanged to"Legacy"DALI mode, and the DALI ballasts must be addressedand grouped usingtheCrestron Toolbox DALI Commissioning 2.0 Tool.148 +ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 171 171 172 -To change modes, run the appropriate dalisetmode command, wait 5 seconds, and then reboot the ZUMNET-JBOX-DALI: 150 +1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 151 +1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 173 173 174 -* Set Legacy mode: ##dalisetmode 1 1## 175 -* Set Groups mode: ##dalisetmode 1 2## 153 +The commands to view or change the Master/Slave mode are: 176 176 177 -=== Zūm Mode Auto Switch === 155 +* View current mode: ##zwms## 156 +* Make "master": ##zwms master## 157 +* Make "slave": ##zwms slave## 178 178 179 - Zūm ModeAutoSwitch is a featureintroducedby Crestron in November of 2022 with.puf firmware v1.04.05 (device firmware 1.004.00005). Thisfeatureis intended to address concerns that arose from projectsusing custom programs with ZUMNET-JBOX-* devices in CNET Mode.Previously, ifa device in CNET Mode lostconnection to theprocessor, then it wouldbe impossibletomaintain any sort of control over the lighting. With Zūm Mode Auto Switch enabled,a ZUMNET-JBOX running in CNET Mode will automatically switchto App Modeand process local logic in theevent that it loses connection to the processor.159 +A reboot is required if the mode is to be changed. 180 180 181 - Enable ZūmMode Auto Switchusingthe command: ##autoswitchon##161 += Changing IP-IDs = 182 182 183 -Rebooting after changing Auto Switch modes is not officially required, but is still recommended. 184 - 185 -//Any configuration changes made through the Zūm App should be made while the control processor is disconnected: the easiest ways to accomplish this are to either disconnect the Cat5e/Cat6 cable at the processor or use Text Console commands (//##stopprog -p:01##//)to temporarily suspend the custom program on the processor.// 186 - 187 -== Changing IP-IDs == 188 - 189 189 If ZUMNET-JBOXs must be assigned different IP-IDs than indicated in the SRTakeoff.xlsx, or if Zūm Link devices are moved between ZUMNET-JBOXs, then the configuration file must be updated. Every Zūm Link device in the configuration has a ##"DeviceHostId"## associated with it, which corresponds to the IP-ID of the ZUMNET-JBOX hosting it. 190 190 191 191 If a Zūm Link device is moved from one ZUMNET-JBOX to another, then this ##"DeviceHostId"## must be updated with the IP-ID of the new device. ... ... @@ -197,3 +197,4 @@ 197 197 [[image:1655247008527-737.png]] 198 198 199 199 [[image:1655246948921-246.png]] 174 +)))