Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 43.1
edited by Alexander Mott
on 2023/05/16 14:29
on 2023/05/16 14:29
Change comment:
There is no comment for this version
To version 39.1
edited by Scott Kohlmann
on 2023/04/20 22:53
on 2023/04/20 22:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -8,6 +8,8 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 +(% class="row" %) 12 +((( 11 11 Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with ShowRunnerCLC™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. 12 12 13 13 Much like DIN-CENCN-2s in ShowRunnerCLC™ installations, ZUMNET-JBOXs identify themselves to the processor via their IP-ID, so the specific IP address of any given ZUMNET-JBOX does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. If hosted devices are moved between ZUMNET-JBOXs, or if the ZUMNET-JBOX needs to have a different IP-ID than it was initially assigned, the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet which will list all the Zūm Net and Zūm Link devices and their associated IP-IDs. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. ZUMNET-JBOX's will typically start with IP-IDs in the 30-5F range, but can potentially exceed this range. ... ... @@ -110,12 +110,12 @@ 110 110 111 111 * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX 112 112 * Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%); the hostname can be skipped if it has already been configured from the Crestron Zūm App) 115 +** Disable DHCP: ##dhcp off## 113 113 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)## 114 114 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 115 115 ** Set default gateway: ##defr 0 **10.0.0.1**## 116 116 ** Update IP table: ##addm (% style="color:olive" %)**30**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 117 117 ** Set hostname: ##host (% style="color:purple" %)**ZNET-JBOX-RM-201**(%%)## 118 -** Disable DHCP: ##dhcp off## 119 119 ** Reboot the ZUMNET-JBOX: ##reboot## 120 120 *** Note that rebooting the JBOX will cause the lights to briefly cut out 121 121 * Repeat for all ZUMNET-JBOXs on the job ... ... @@ -136,32 +136,20 @@ 136 136 137 137 A reboot is required if the mode is to be changed. Note that this command will also display the current Master/Slave mode, but will not allow you to change it. 138 138 139 -== Primary/SecondaryMode ==141 +== Master/Slave Mode == 140 140 141 -(% class="box warningmessage" %) 142 -((( 143 -Zūm Wired firmware v1.03.27 (device firmware v1.002.00026) updates the terminology from "master"/"slave" to "primary"/"secondary", and changes the ##zwms## command to ##zwps## 144 -Devices running this newer firmware will not accept commands using "master"/"slave" as arguments. 145 -))) 143 +ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 146 146 147 -ZUMNET-JBOXs can be in either "Primary" or "Secondary" mode. In most situations, "Primary" is the desired mode of operations, as "Secondary" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX and prevents it from discovering devices on the Zūm Link bus or performing any logic. There are two scenarios in which a ZUMNET-JBOX should be configured in "Secondary" mode: 148 - 149 149 1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 150 150 1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 151 151 152 - ZUMNET-JBOXs withfirmware1.006.00012 or newer will ship from the factory in "Primary"mode, but will go to "Secondary" mode if a hardware reset is performed. ZUMNET-JBOXs with older firmware will ship in"Secondary" mode. The commands to view or change thePrimary/Secondarymode are:148 +The commands to view or change the Master/Slave mode are: 153 153 154 -* View current mode: 155 -** Current FW: ##zwps## or ##zwmode## 156 -** Old FW: ##zwms## 157 -* Make "Primary": 158 -** Current FW: ##zwps primary## 159 -** Old FW: ##zwms master## 160 -* Make "Secondary": 161 -** Current FW: ##zwps secondary## 162 -** Old FW: ##zwms slave## 150 +* View current mode: ##zwms## 151 +* Make "master": ##zwms master## 152 +* Make "slave": ##zwms slave## 163 163 164 -A reboot is required if the mode is changed. 154 +A reboot is required if the mode is to be changed. 165 165 166 166 = Changing IP-IDs = 167 167 ... ... @@ -176,3 +176,4 @@ 176 176 [[image:1655247008527-737.png]] 177 177 178 178 [[image:1655246948921-246.png]] 169 +)))