Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 40.1
edited by Alexander Mott
on 2023/05/15 18:16
on 2023/05/15 18:16
Change comment:
There is no comment for this version
To version 45.1
edited by Alexander Mott
on 2023/10/06 22:52
on 2023/10/06 22:52
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,8 +8,6 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 13 Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with ShowRunnerCLC™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. 14 14 15 15 Much like DIN-CENCN-2s in ShowRunnerCLC™ installations, ZUMNET-JBOXs identify themselves to the processor via their IP-ID, so the specific IP address of any given ZUMNET-JBOX does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. If hosted devices are moved between ZUMNET-JBOXs, or if the ZUMNET-JBOX needs to have a different IP-ID than it was initially assigned, the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet which will list all the Zūm Net and Zūm Link devices and their associated IP-IDs. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. ZUMNET-JBOX's will typically start with IP-IDs in the 30-5F range, but can potentially exceed this range. ... ... @@ -108,8 +108,10 @@ 108 108 109 109 == Assigning Permanent Static IP Addresses and IP-IDs == 110 110 111 -Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID :109 +Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID. 112 112 111 +Note that static IP addresses are only required on jobs where there is no permanent DHCP server. Manual IP-ID assignment is not required for jobs intended to be used with Zūm Auto Discovery, though it may still be recommended in order to keep track and document which IP-ID is associated with each area (Auto Discovery will auto-assign IP-IDs to ZUMNET-JBOXs without IP-IDs, but if a ZUMNET-JBOX already has an IP table entry it will be imported to the configuration with that pre-existing IP-ID). 112 + 113 113 * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX 114 114 * Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%); the hostname can be skipped if it has already been configured from the Crestron Zūm App) 115 115 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)## ... ... @@ -124,8 +124,35 @@ 124 124 125 125 = Zūm Net Specific Configuration = 126 126 127 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode a ndMaster/Slave mode.ZUMNET-JBOXsshould shipasMasterdevicesinZūmModefromthefactory, and thisistypically the desiredsetting.127 +Zūm Net devices have a two additional settings not present for other devices: Primary/Secondary mode and Zūm/Cresnet mode. ZUMNET-JBOX-DALI have a third setting for Group/Legacy DALI mode, and all ZUMNET-JBOX-* that are in CNET mode can optionally be configured to automatically switch back and forth between CNET and App mode depending on whether the control processor is reachable. 128 128 129 +== Primary/Secondary Mode == 130 + 131 +(% class="box warningmessage" %) 132 +((( 133 +Zūm Wired firmware v1.03.27 (device firmware v1.002.00026) updates the terminology from "master"/"slave" to "primary"/"secondary", and changes the ##zwms## command to ##zwps## 134 +Devices running this newer firmware will not accept commands using "master"/"slave" as arguments. 135 +))) 136 + 137 +ZUMNET-JBOXs can be in either "Primary" or "Secondary" mode. In most situations, "Primary" is the desired mode of operations, as "Secondary" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX and prevents it from discovering devices on the Zūm Link bus or performing any logic. There are two scenarios in which a ZUMNET-JBOX should be configured in "Secondary" mode: 138 + 139 +1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 140 +1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 141 + 142 +ZUMNET-JBOXs with firmware 1.006.00012 or newer will ship from the factory in "Primary" mode, but will go to "Secondary" mode if a hardware reset is performed. ZUMNET-JBOXs with older firmware will ship in "Secondary" mode. The commands to view or change the Primary/Secondary mode are: 143 + 144 +* View current mode: 145 +** Current FW: ##zwps## or ##zwmode## 146 +** Old FW: ##zwms## 147 +* Make "Primary": 148 +** Current FW: ##zwps primary## 149 +** Old FW: ##zwms master## 150 +* Make "Secondary": 151 +** Current FW: ##zwps secondary## 152 +** Old FW: ##zwms slave## 153 + 154 +A reboot is required if the mode is changed. 155 + 129 129 == Zūm/Cresnet Mode == 130 130 131 131 Zūm Mode (also known as App Mode) is the default setting for new ZUMNET-JBOXs, and allows them to be configured from the Crestron Zūm App. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled. Generally, Cresnet mode is only required if non-Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads) or if certain ShowRunnerCLC™ features are required (such as changing the dimming response curve). ... ... @@ -138,23 +138,27 @@ 138 138 139 139 A reboot is required if the mode is to be changed. Note that this command will also display the current Master/Slave mode, but will not allow you to change it. 140 140 141 -== Master/Slave Mode ==168 +=== DALI Group/Legacy Mode === 142 142 143 -ZUMNET-JBOX sship in"Master"modeby default, andgenerallythisishow theyshould be configured."Slave" modeeffectivelyturnsaZUMNET-JBOXinto a ZUMLINK-JBOX.Therearetwoscenariosinwhich a ZUMNET-JBOXwillneed tobefigured in"Slave"mode:170 +ZUMNET-JBOX-DALI that are operating in App mode should be kept in "Groups" DALI mode, and DALI loads must be configured through the Zūm App. ZUMNET-JBOX-DALI that are operating in CNET mode with ShowRunner™ must be changed to "Legacy" DALI mode, and the DALI ballasts must be addressed and grouped using the Crestron Toolbox DALI Commissioning 2.0 Tool. 144 144 145 -1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 146 -1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 172 +To change modes, run the appropriate dalisetmode command, wait 5 seconds, and then reboot the ZUMNET-JBOX-DALI: 147 147 148 -The commands to view or change the Master/Slave mode are: 174 +* Set Legacy mode: ##dalisetmode 1 1## 175 +* Set Groups mode: ##dalisetmode 1 2## 149 149 150 -* View current mode: ##zwms## 151 -* Make "master": ##zwms master## 152 -* Make "slave": ##zwms slave## 177 +=== Zūm Mode Auto Switch === 153 153 154 -A reboot is re quired if themode is tobe changed.179 +Zūm Mode Auto Switch is a feature introduced by Crestron in November of 2022 with .puf firmware v1.04.05 (device firmware 1.004.00005). This feature is intended to address concerns that arose from projects using custom programs with ZUMNET-JBOX-* devices in CNET Mode. Previously, if a device in CNET Mode lost connection to the processor, then it would be impossible to maintain any sort of control over the lighting. With Zūm Mode Auto Switch enabled, a ZUMNET-JBOX running in CNET Mode will automatically switch to App Mode and process local logic in the event that it loses connection to the processor. 155 155 156 - =ChangingIP-IDs=181 +Enable Zūm Mode Auto Switch using the command: ##autoswitch on## 157 157 183 +Rebooting after changing Auto Switch modes is not officially required, but is still recommended. 184 + 185 +//Any configuration changes made through the Zūm App should be made while the control processor is disconnected: the easiest ways to accomplish this are to either disconnect the Cat5e/Cat6 cable at the processor or use Text Console commands (//##stopprog -p:01##//)to temporarily suspend the custom program on the processor.// 186 + 187 +== Changing IP-IDs == 188 + 158 158 If ZUMNET-JBOXs must be assigned different IP-IDs than indicated in the SRTakeoff.xlsx, or if Zūm Link devices are moved between ZUMNET-JBOXs, then the configuration file must be updated. Every Zūm Link device in the configuration has a ##"DeviceHostId"## associated with it, which corresponds to the IP-ID of the ZUMNET-JBOX hosting it. 159 159 160 160 If a Zūm Link device is moved from one ZUMNET-JBOX to another, then this ##"DeviceHostId"## must be updated with the IP-ID of the new device. ... ... @@ -166,4 +166,3 @@ 166 166 [[image:1655247008527-737.png]] 167 167 168 168 [[image:1655246948921-246.png]] 169 -)))