Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
To version 18.1
edited by Alexander Mott
on 2022/06/21 18:11
on 2022/06/21 18:11
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box" %) 2 -((( 3 -This article is for configuring Zūm Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 -))) 5 - 6 6 === Zūm Net Devices in SHOWRUNNER™ === 7 7 8 8 Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with SHOWRUNNER™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. ... ... @@ -79,8 +79,6 @@ 79 79 80 80 If all hostnames have been set, then it becomes very easy to know which DHCP assigned IP address is associated with each room using the Device Summary. Generate a Device Summary with the new hostnames and proceed to IP configuration. 81 81 82 -Full instructions on configuring Zūm Wired using the Crestron Zūm App, can be found [[here>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 83 - 84 84 ===== Identifying by Serial Number or MAC Address ===== 85 85 86 86 Both the serial number and MAC address are printed onto each ZUMNET-JBOX. Just like with Cresnet jobs, it is good practice for the electrical contractor to record serial numbers as they install devices. It is also good to collect the MAC addresses, but it is not necessary since Device Summary will have both the serial number and MAC address. ... ... @@ -153,6 +153,24 @@ 153 153 154 154 A reboot is required if the mode is to be changed. 155 155 149 +=== Problems Connecting to Zūm Room (Error 13) === 150 + 151 +If you cannot connect to the Zūm Room (i.e., the primary ZUMNET-JBOX for the room) using the Crestron Zūm App: 152 + 153 +* Verify the ZUMNET-JBOX is in "zum" mode 154 +* Verify that the primary ZUMNET-JBOX for the room is in "master" mode 155 +* Confirm you are on an Android device (the iOS app does not currently support Zūm Wired devices) 156 +* If you get an "Error 13" code: 157 +** Uninstall the app 158 +** Reboot your phone 159 +** Reinstall the app 160 +** Navigate to Android Application settings 161 +** Navigate to the Crestron Zūm App 162 +** Clear storage for the Crestron Zūm App 163 +** Open the Crestron Zūm App and accept the license agreements 164 +** Connect to the Zūm Room 165 +** When prompted, input a valid pin (default is 2468) 166 + 156 156 === Changing IP-IDs === 157 157 158 158 If ZUMNET-JBOXs must be assigned different IP-IDs than indicated in the SRTakeoff.xlsx, or if Zūm Link devices are moved between ZUMNET-JBOXs, then the configuration file must be updated. Every Zūm Link device in the configuration has a ##"DeviceHostId"## associated with it, which corresponds to the IP-ID of the ZUMNET-JBOX hosting it.