Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 17.1
edited by Alexander Mott
on 2022/06/17 19:43
on 2022/06/17 19:43
Change comment:
Renamed from xwiki:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.ZUMNET-JBOX Setup.WebHome
To version 19.1
edited by Alexander Mott
on 2022/06/22 22:19
on 2022/06/22 22:19
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.WebHome 1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome - Content
-
... ... @@ -1,3 +1,8 @@ 1 +(% class="box infomessage" %) 2 +((( 3 +This article is for configuring Zum Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Crestron Zūm App Overview.WebHome]]. 4 +))) 5 + 1 1 === Zūm Net Devices in SHOWRUNNER™ === 2 2 3 3 Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with SHOWRUNNER™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. ... ... @@ -74,6 +74,8 @@ 74 74 75 75 If all hostnames have been set, then it becomes very easy to know which DHCP assigned IP address is associated with each room using the Device Summary. Generate a Device Summary with the new hostnames and proceed to IP configuration. 76 76 82 +Full instructions on configuring Zūm Wired using the Crestron Zūm App, can be found [[here>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Crestron Zūm App Overview.WebHome]]. 83 + 77 77 ===== Identifying by Serial Number or MAC Address ===== 78 78 79 79 Both the serial number and MAC address are printed onto each ZUMNET-JBOX. Just like with Cresnet jobs, it is good practice for the electrical contractor to record serial numbers as they install devices. It is also good to collect the MAC addresses, but it is not necessary since Device Summary will have both the serial number and MAC address.