Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 10.8
edited by Alexander Mott
on 2022/06/17 17:13
on 2022/06/17 17:13
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.WebHome 1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome - Content
-
... ... @@ -1,3 +1,8 @@ 1 +(% class="box" %) 2 +((( 3 +This article is for configuring Zūm Net devices using Crestron Toolbox. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 +))) 5 + 1 1 === Zūm Net Devices in SHOWRUNNER™ === 2 2 3 3 Zūm Net devices are part of Crestron's latest Zūm Wired system, acting as a the main lighting controller for a Zūm Wired room. In networked applications of Zūm Wired, they also act as bridges connecting the local Zūm Link devices in each room to the overall lighting network throughout the building. Since Zūm Link and Cresnet are [[interchangeable>>https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/#HZ16BmLink]], and Zūm Net is an Ethernet protocol, this means that Zūm Net devices can be thought of as single-net DIN-CENCN-2s. As of Summer 2022, there are only two Zūm Net devices that have been announced and are in production: the ZUMNET-JBOX-16A-LV 0-10V load controller and the ZUMNET-JBOX-DALI DALI load controller. Configuring these devices for use with SHOWRUNNER™ is identical, so they will be referred to collectively as ZUMNET-JBOXs for the purposes of this article. ... ... @@ -47,6 +47,13 @@ 47 47 ** Though saved as a text file, the Device Summary is actually a table of comma separated values 48 48 ** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 49 49 55 +Below is an example of a Device Summary for a fully-configured job: 56 + 57 +* DeviceSummary.txt: 58 +[[image:1655487020590-542.png]] 59 +* DeviceSummary.csv: 60 +[[image:1655487132138-904.png]] 61 + 50 50 Once the Device Summary has been generated, proceed to identifying each ZUMNET-JBOX using the hostname, SN/MAC, or Device Tree View methods described below. 51 51 52 52 ===== Identifying by Hostname ===== ... ... @@ -67,25 +67,21 @@ 67 67 68 68 If all hostnames have been set, then it becomes very easy to know which DHCP assigned IP address is associated with each room using the Device Summary. Generate a Device Summary with the new hostnames and proceed to IP configuration. 69 69 82 +Full instructions on configuring Zūm Wired using the Crestron Zūm App, can be found [[here>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 70 70 84 +===== Identifying by Serial Number or MAC Address ===== 71 71 72 - Iftheelectrical contractorhas provided alist of which serial numbers/MAC addressesbelongto eachinstalledZUMNET-JBOX,then it is relativelyeasytoidentifywhichZUMNET-JBOXshouldgetwhichIP-ID:86 +Both the serial number and MAC address are printed onto each ZUMNET-JBOX. Just like with Cresnet jobs, it is good practice for the electrical contractor to record serial numbers as they install devices. It is also good to collect the MAC addresses, but it is not necessary since Device Summary will have both the serial number and MAC address. 73 73 74 -* Connect to the lighting network and open Device Discovery Tool in Toolbox 75 -* The Device Discovery tool will automatically report how many Ethernet devices have been discovered 76 -** Verify that the correct number of Ethernet devices have been discovered, including any TSWs, GLPACs, DIN-CENCN-2s, etc. 77 -** Note that only Crestron devices will appear in Device Discovery; non-Crestron devices (such as Pharos or Enttec DMX controllers) will not appear in Device Discovery Tool 78 -* Click the "Export..." button below the list of discovered devices 79 -** If this button says "Address Book", then Toolbox needs to be updated 80 -* Click the Write Device Summary button and save the DeviceSummary.txt to your computer 81 -* The DeviceSummary.txt provides the IP address, MAC address, and serial number for each device on the network 82 -* Cross reference the DeviceSummary.txt with the serial numbers/MAC addresses provided by the installer in order to determine which ZUMNET-JBOX has been assigned each IP address 83 -* Update the SRTakeoff.xlsx with the device serial number, MAC address, and automatically assigned IP address for all ZUMNET-JBOXs 88 +If the electrical contractor has provided a list of which serial numbers/MAC addresses belong to each installed ZUMNET-JBOX, then generate a Device Summary and proceed to IP configuration. 84 84 85 - Iftheelectrical contractor has not provided a list ofwhich serialnumbers/MAC addresses belong to eachinstalled ZUMNET-JBOX, then it is necessary toconnect to each ZUMNET-JBOX individually and identify them throughToolbox. Putting a device into identifywill stop any programs running on a processor, and takinga deviceout of identify mode will restart the program.This starting/stopping of theprogram can betimeconsumingwhena large number of devices are being identified, so it may be a good idea to run the ##stopprog -p:01## command on the processor prior to identifying devices. Once all the devices are identified, run the ##progreset## command to resume the program.90 +===== Identifying through Network Device Tree View ===== 86 86 87 -* Connect to the lighting network and open Device Discovery Tool in Toolbox 88 -* Note the IP addresses for all of the installed ZUMNET-JBOXs 92 +If the electrical contractor has not provided a list of which serial numbers/MAC addresses belong to each installed ZUMNET-JBOX and nobody intends to rename each ZUMNET-JBOX using the Crestron Zūm App, then the only way to identify which ZUMNET-JBOX is installed where is to use the Device Tree View tool in Toolbox. This is by far the slowest and most disruptive way to identify devices, so it is only recommended as a last resort. 93 + 94 +Putting a ZUMNET-JBOX into identify mode will make it continuously produce an alarm-clock sound and flash any connected loads. Additionally, putting a device into identify mode will stop any programs running on a processor, and taking a device out of identify mode will restart the program. This starting/stopping of the program can be time consuming when a large number of devices are being identified, so it may be a good idea to suspend the program using the ##stopprog -p:01## command on the processor prior to identifying devices. Once all the devices are identified, run the ##progreset## command to resume the program. 95 + 96 +* Generate a Device Summary and note the IP addresses for all installed ZUMNET-JBOXs 89 89 * Connect to the first ZUMNET-JBOX using Network Device Tree View 90 90 * Locate the "ZUMNET-JBOX-xx-xx-LOCAL" device in the list of connected devices 91 91 ** The model will vary between 0-10V and DALI JBOXs ... ... @@ -93,15 +93,17 @@ 93 93 * Right click the device and press "Identify This Device..." from the context menu 94 94 * The device will blink any attached fixtures and make an alarm sound 95 95 * Walk around the jobsite until the room/controlled fixtures are located 96 -* Updatethe SRTakeoff.xlsxwiththe device serialnumber,MAC address, and automaticallyassignedIP address97 -* Repeat all stepsfor each ZUMNET-JBOXsuntil all of the ZUMNET-JBOXs have been identified104 +* Edit the Device Summary or SRTakeoff.xlsx so that you remember which JBOX is which 105 +* Repeat for each ZUMNET-JBOX until all of the ZUMNET-JBOXs have been identified 98 98 107 +Once you have determined and recorded which ZUMNET-JBOX is which, you may proceed to IP configuration. 108 + 99 99 ==== Assigning Permanent Static IP Addresses and IP-IDs ==== 100 100 101 101 Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID: 102 102 103 103 * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX 104 -* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%)) 114 +* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%); the hostname can be skipped if it has already been configured from the Crestron Zūm App) 105 105 ** Disable DHCP: ##dhcp off## 106 106 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)## 107 107 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## ... ... @@ -109,6 +109,7 @@ 109 109 ** Update IP table: ##addm (% style="color:olive" %)**30**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 110 110 ** Set hostname: ##host (% style="color:purple" %)**ZNET-JBOX-RM-201**(%%)## 111 111 ** Reboot the ZUMNET-JBOX: ##reboot## 122 +*** Note that rebooting the JBOX will cause the lights to briefly cut out 112 112 * Repeat for all ZUMNET-JBOXs on the job 113 113 114 114 === Zūm Net Specific Configuration ===
- 1655487002500-174.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- 1655487008788-390.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- 1655487020590-542.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- 1655487132138-904.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.0 KB - Content