Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 10.8
edited by Alexander Mott
on 2022/06/17 17:13
on 2022/06/17 17:13
Change comment:
There is no comment for this version
To version 10.4
edited by Alexander Mott
on 2022/06/17 16:50
on 2022/06/17 16:50
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,7 +29,7 @@ 29 29 30 30 1. Identifying by hostname 31 31 1. Identifying by serial number or MAC address 32 -1. Identifying through DeviceTree View32 +1. Identifying through Toolbox 33 33 34 34 Each of these methods involves generating a Device Summary using the Device Discovery Tool in Toolbox. The Device Summary is a file which lists all devices that are discoverable on the network along with useful information such as their hostname, IP address, and MAC address. 35 35 ... ... @@ -47,28 +47,10 @@ 47 47 ** Though saved as a text file, the Device Summary is actually a table of comma separated values 48 48 ** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 49 49 50 -Once the Device Summary has been generated, proceed to identifying each ZUMNET-JBOX using the hostname, SN/MAC, or Device Tree View methods described below. 51 - 52 52 ===== Identifying by Hostname ===== 53 53 54 - The Crestron Zūm App is used to configure the internal logic of Zūm Wired rooms. This internal logic determines the room behavior when ZUMNET-JBOXs are used in standalone applications or ifcommunication to theprocessor is lost. Evenon SHOWRUNNER™ jobs with a central program running the lighting controls, it is best practice to configure the internal logic tomatch as closely aspossible the SHOWRUNNER™ logic in order to minimize disruption to end-users in the event of a processor or network failure.52 +Oftentimes, 55 55 56 -In addition to configuring default room logic, the Crestron Zūm App can be used to change the hostname of the ZUMNET-JBOX for each room. By default, the hostname for a ZUMNET-JBOX is the model followed by the last six digits of the MAC address, e.g. "ZUMNET-JBOX-16A-LV-F2DA94". If you or the electrical contractor already intend to configure the internal logic each ZUMNET-JBOX, it would be a good idea to also change the hostname to something more identifiable. 57 - 58 -To change the hostname using the Crestron Zūm App: 59 - 60 -* Connect to the ZUMNET-JBOX in the App 61 -* Tap "Room Settings" 62 -* Tap "Network" 63 -* Tap the Hostname field and edit the Hostname 64 -* Scroll to the bottom of the page and tap "Save settings" 65 -* Tap "OK" to apply the changes and reboot the ZUMNET-JBOX 66 -** Note that rebooting the JBOX will cause the lights to briefly cut out 67 - 68 -If all hostnames have been set, then it becomes very easy to know which DHCP assigned IP address is associated with each room using the Device Summary. Generate a Device Summary with the new hostnames and proceed to IP configuration. 69 - 70 - 71 - 72 72 If the electrical contractor has provided a list of which serial numbers/MAC addresses belong to each installed ZUMNET-JBOX, then it is relatively easy to identify which ZUMNET-JBOX should get which IP-ID: 73 73 74 74 * Connect to the lighting network and open Device Discovery Tool in Toolbox ... ... @@ -113,12 +113,14 @@ 113 113 114 114 === Zūm Net Specific Configuration === 115 115 116 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in Zūm Mode from the factory, and this is typically the desired setting.98 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. 117 117 118 118 ==== Zūm/Cresnet Mode ==== 119 119 120 -Z ūmMode(alsoknownasAppMode)isthedefault setting fornewZUMNET-JBOXs, andallowsthemto beonfiguredfromthe Crestron ZūmApp. If a ZUMNET-JBOXisputinto Cresnetmode, itwillno longerbe able to be configuredusing the Crestron Zūm App andall internal logicwillbedisabled.Generally, Cresnetmodeisonly requiredif non-ZūmLink devices areconnectedto the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmerr C2N-CBD-P Cameokeypads)or if certain SHOWRUNNER™ featuresare required (such as changingthedimmingresponsecurve).102 +ZUMNET-JBOXs should ship in "Zūm Mode" by default, also known as "App Mode" because this is the setting required to be able to configure Zūm Wired rooms using the Crestron Zūm Mobile App. 121 121 104 +If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the App and all internal logic will be disabled. Generally, Cresnet mode is only required if non Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads). 105 + 122 122 The commands to view or change the Zūm/Cresnet mode are: 123 123 124 124 * View current mode: ##zwmode## ... ... @@ -129,8 +129,10 @@ 129 129 130 130 ==== Master/Slave Mode ==== 131 131 132 -ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode:116 +ZUMNET-JBOXs should ship in "Master" mode by default, and generally this is how they should be configured. 133 133 118 +"Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 119 + 134 134 1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 135 135 1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 136 136