Changes for page Zūm Net Device Setup
Last modified by Alexander Mott on 2024/10/22 19:55
From version 10.6
edited by Alexander Mott
on 2022/06/17 16:55
on 2022/06/17 16:55
Change comment:
There is no comment for this version
To version 10.3
edited by Alexander Mott
on 2022/06/17 16:47
on 2022/06/17 16:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,9 +43,10 @@ 43 43 ** If some devices are missing, there may be an issue with your DHCP server settings or the network wiring 44 44 * Click the "Export..." button below the list of discovered devices 45 45 ** If this button says "Address Book", then Toolbox needs to be updated 46 -* Click the Write Device Summary button and save the Device Summary to your computer 47 -** Though saved as a text file, the Device Summary is actually a table of comma separated values 48 -** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 46 +* Click the Write Device Summary button and save the DeviceSummary.txt to your computer 47 +* The DeviceSummary.txt provides the IP address, MAC address, and serial number for each device on the network 48 +* Cross reference the DeviceSummary.txt with the serial numbers/MAC addresses provided by the installer in order to determine which ZUMNET-JBOX has been assigned each IP address 49 +* Update the SRTakeoff.xlsx with the device serial number, MAC address, and automatically assigned IP address for all ZUMNET-JBOXs 49 49 50 50 ===== Identifying by Hostname ===== 51 51 ... ... @@ -95,12 +95,14 @@ 95 95 96 96 === Zūm Net Specific Configuration === 97 97 98 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in Zūm Mode from the factory, and this is typically the desired setting.99 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. 99 99 100 100 ==== Zūm/Cresnet Mode ==== 101 101 102 -Z ūmMode(alsoknownasAppMode)isthedefault setting fornewZUMNET-JBOXs, andallowsthemto beonfiguredfromthe Crestron ZūmApp. If a ZUMNET-JBOXisputinto Cresnetmode, itwillno longerbe able to be configuredusing the Crestron Zūm App andall internal logicwillbedisabled.Generally, Cresnetmodeisonly requiredif non-ZūmLink devices areconnectedto the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmerr C2N-CBD-P Cameokeypads)or if certain SHOWRUNNER™ featuresare required (such as changingthedimmingresponsecurve).103 +ZUMNET-JBOXs should ship in "Zūm Mode" by default, also known as "App Mode" because this is the setting required to be able to configure Zūm Wired rooms using the Crestron Zūm Mobile App. 103 103 105 +If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the App and all internal logic will be disabled. Generally, Cresnet mode is only required if non Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads). 106 + 104 104 The commands to view or change the Zūm/Cresnet mode are: 105 105 106 106 * View current mode: ##zwmode## ... ... @@ -111,8 +111,10 @@ 111 111 112 112 ==== Master/Slave Mode ==== 113 113 114 -ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode:117 +ZUMNET-JBOXs should ship in "Master" mode by default, and generally this is how they should be configured. 115 115 119 +"Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode: 120 + 116 116 1. It is connected to another ZUMNET-JBOX via the Zūm Link bus 117 117 1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter 118 118