Changes for page Zūm Net Device Setup

Last modified by Alexander Mott on 2024/10/22 19:55

From version 10.3
edited by Alexander Mott
on 2022/06/17 16:47
Change comment: There is no comment for this version
To version 10.6
edited by Alexander Mott
on 2022/06/17 16:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -43,10 +43,9 @@
43 43  ** If some devices are missing, there may be an issue with your DHCP server settings or the network wiring
44 44  * Click the "Export..." button below the list of discovered devices
45 45  ** If this button says "Address Book", then Toolbox needs to be updated
46 -* Click the Write Device Summary button and save the DeviceSummary.txt to your computer
47 -* The DeviceSummary.txt provides the IP address, MAC address, and serial number for each device on the network
48 -* Cross reference the DeviceSummary.txt with the serial numbers/MAC addresses provided by the installer in order to determine which ZUMNET-JBOX has been assigned each IP address
49 -* Update the SRTakeoff.xlsx with the device serial number, MAC address, and automatically assigned IP address for all ZUMNET-JBOXs
46 +* Click the Write Device Summary button and save the Device Summary to your computer
47 +** Though saved as a text file, the Device Summary is actually a table of comma separated values
48 +** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc
50 50  
51 51  ===== Identifying by Hostname =====
52 52  
... ... @@ -96,14 +96,12 @@
96 96  
97 97  === Zūm Net Specific Configuration ===
98 98  
99 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode.
98 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in Zūm Mode from the factory, and this is typically the desired setting.
100 100  
101 101  ==== Zūm/Cresnet Mode ====
102 102  
103 -ZUMNET-JBOXs should ship in "Zūm Mode" by default, also known as "App Mode" because this is the setting required to be able to configure Zūm Wired rooms using the Crestron Zūm Mobile App.
102 +Zūm Mode (also known as App Mode) is the default setting for new ZUMNET-JBOXs, and allows them to be configured from the Crestron Zūm App. If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the Crestron Zūm App and all internal logic will be disabled. Generally, Cresnet mode is only required if non-Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads) or if certain SHOWRUNNER™ features are required (such as changing the dimming response curve).
104 104  
105 -If a ZUMNET-JBOX is put into Cresnet mode, it will no longer be able to be configured using the App and all internal logic will be disabled. Generally, Cresnet mode is only required if non Zūm Link devices are connected to the ZUMNET-JBOX (e.g. a GL-EXP-DIMU-CN phase dimmer or C2N-CBD-P Cameo keypads).
106 -
107 107  The commands to view or change the Zūm/Cresnet mode are:
108 108  
109 109  * View current mode: ##zwmode##
... ... @@ -114,10 +114,8 @@
114 114  
115 115  ==== Master/Slave Mode ====
116 116  
117 -ZUMNET-JBOXs should ship in "Master" mode by default, and generally this is how they should be configured.
114 +ZUMNET-JBOXs ship in "Master" mode by default, and generally this is how they should be configured. "Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode:
118 118  
119 -"Slave" mode effectively turns a ZUMNET-JBOX into a ZUMLINK-JBOX. There are two scenarios in which a ZUMNET-JBOX will need to be configured in "Slave" mode:
120 -
121 121  1. It is connected to another ZUMNET-JBOX via the Zūm Link bus
122 122  1. It is being used as a Cresnet device, connected to a processor or DIN-CENCN-2 using a Cresnet/Zūm Link adapter
123 123