... ... @@ -31,6 +31,22 @@
31 31  1. Identifying by serial number or MAC address
32 32  1. Identifying through Toolbox
33 33  
34 +Each of these methods involves generating a Device Summary using the Device Discovery Tool in Toolbox. The Device Summary is a file which lists all devices that are discoverable on the network along with useful information such as their hostname, IP address, and MAC address.
35 +
36 +To generate a Device Summary in Toolbox:
37 +
38 +* Connect to the lighting network and open Device Discovery Tool in Toolbox
39 +* The Device Discovery tool will automatically report how many Ethernet devices have been discovered
40 +* Verify that the expected number of Ethernet devices have been discovered, including any TSWs, GLPACs, DIN-CENCN-2s, etc.
41 +** Note that only Crestron devices will appear in Device Discovery; non-Crestron devices (such as Pharos or Enttec DMX controllers) will not appear in Device Discovery Tool
42 +** If no devices are discovered, verify that your computer is connected to the network and your IP address is compatible with the network
43 +** If some devices are missing, there may be an issue with your DHCP server settings or the network wiring
44 +* Click the "Export..." button below the list of discovered devices
45 +** If this button says "Address Book", then Toolbox needs to be updated
46 +* Click the Write Device Summary button and save the Device Summary to your computer
47 +** Though saved as a text file, the Device Summary is actually a table of comma separated values
48 +** Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc
49 +
34 34  ===== Identifying by Hostname =====
35 35  
36 36  Oftentimes,
... ... @@ -67,9 +67,9 @@
67 67  Once you have identified which IP address has been assigned to each ZUMNET-JBOX, you can begin configuring them with permanent static IP addresses and the correct IP-ID:
68 68  
69 69  * Open Text Console in Toolbox and connect to the first ZUMNET-JBOX
70 -* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.20**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%))
86 +* Run the following commands to configure the ZUMNET-JBOXs IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a permanent IP address of (% style="color:blue" %)**10.0.0.80**(%%), an IP-ID of (% style="color:olive" %)**30**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:#800080" %)**ZNET-JBOX-RM-201**(%%))
71 71  ** Disable DHCP: ##dhcp off##
72 -** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.20**(%%)##
88 +** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.80**(%%)##
73 73  ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)##
74 74  ** Set default gateway: ##defr 0 **10.0.0.1**##
75 75  ** Update IP table: ##addm (% style="color:olive" %)**30**(%%) (% style="color:orange" %)**10.0.0.10**(%%)##
... ... @@ -79,7 +79,7 @@
79 79  
80 80  === Zūm Net Specific Configuration ===
81 81  
82 -Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode.
98 +Zūm Net devices have a two additional settings not present for other devices: Zūm/Cresnet mode and Master/Slave mode. ZUMNET-JBOXs should ship as Master devices in App mode from the factory, and this is typically the desired setting.
83 83  
84 84  ==== Zūm/Cresnet Mode ====
85 85