Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 7.1
edited by Alexander Mott
on 2023/12/04 20:02
on 2023/12/04 20:02
Change comment:
Uploaded new attachment "1701720163760-996.png", version {1}
To version 16.1
edited by Alexander Mott
on 2024/02/09 00:58
on 2024/02/09 00:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,14 +8,29 @@ 8 8 9 9 = IP Configuration = 10 10 11 -Typically, each CEN-GWEXER will need to be initially configured via USB (micro ,unless their MAC addresses are already known and the lighting network has a DHCP server(eitherbyrunningDHCP server software on your computer,oriftheprocessorhas a control subnetoris running11 +Typically, each CEN-GWEXER will need to be initially configured via USB (microUSB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 12 12 13 -CEN-GWEXER sfor the first time, it may be necessary to manually change the connection type from "Auto" to "SSL/TLS". It is also necessary to manually edit the CEN-GWEXER's address book entry so that the connection protocol is "SSL/TLS" when a CEN-GWEXER is added to the address book using Device Discovery tool export.13 +When connecting to a CEN-GWEXER for the first time, it may be necessary to manually change the connection type from "Auto" to "SSL/TLS". It is also necessary to manually edit the CEN-GWEXER's address book entry so that the connection protocol is "SSL/TLS" when a CEN-GWEXER is added to the address book using Device Discovery tool export. 14 14 15 - Whether connectedto theCEN-GWEXER viaUSBor Ethernet, the process to configure the staticIP addresses is the same:15 +== DHCP Configuration == 16 16 17 +If the lighting network has a permanent DHCP server, then CEN-GWEXERs only require their IP table to be configured, though it is good practice to also record or update their hostname. If the MAC addresses for the CEN-GWEXERs are not known, then the best way to update their configuration is via USB (microUSB). If you are able to identify the CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected to the CEN-GWEXER via USB or Ethernet, the process to configure the IP table and hostname is the same: 18 + 17 17 * Open Text Console in Toolbox and connect to the CEN-GWEXER 18 18 ** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect 21 +* Run the following commands to configure the CEN-GWEXER's IP table and hostname (example is for an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**172.22.0.1**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%)) 22 +** Update IP table: ##addm (% style="color:olive" %)**C1**(%%) (% style="color:orange" %)**172.22.0.1**(%%)## 23 +** Set hostname: ##host (% style="color:purple" %)**GWEXER-L1**(%%)## 24 +** Reboot the CEN-GWEXER: ##reboot## 25 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 26 +* Repeat for all CEN-GWEXERs on the job 27 + 28 +== Static Configuration == 29 + 30 +If there is no permanent DHCP server on the lighting network, then CEN-GWEXERs should be configured with static IP addresses via USB (micro USB). If a temporary DHCP server is connected to the lighting network and you are able to identify CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected via USB or Ethernet, the process to configure the static IP addresses is the same: 31 + 32 +* Open Text Console in Toolbox and connect to the CEN-GWEXER 33 +** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect 19 19 * Run the following commands to configure the CEN-GWEXER's static IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a static IP address of (% style="color:blue" %)**10.0.0.12**(%%), an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%)) 20 20 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.12**(%%)## 21 21 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## ... ... @@ -24,6 +24,7 @@ 24 24 ** Update IP table: ##addm (% style="color:olive" %)**C1**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 25 25 ** Set hostname: ##host (% style="color:purple" %)**GWEXER-L1**(%%)## 26 26 ** Reboot the CEN-GWEXER: ##reboot## 42 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 27 27 * Repeat for all CEN-GWEXERs on the job 28 28 29 29 = SSL Setup = ... ... @@ -48,26 +48,61 @@ 48 48 49 49 = RF Channel = 50 50 51 - Lorem67 +Crestron wireless devices have 16 non-overlapping channels numbered 11-26 to prevent and avoid RF interference either from other appliances in the building (such as microwaves or Wi-Fi routers) or from other Crestron devices that are attempting to communicate with different CEN-GWEXERs. 52 52 53 - ~/~/"RFCHAnnel[#]"set rf channel for gwexer69 +By default, all CEN-GWEXERs will ship with the same RF channel, so for jobs where interference may be an issue it is necessary to manually change the RF channel of the CEN-GWEXERs. When selecting which RF channel to use for each CEN-GWEXER, it is best to avoid using the same RF channel for any CEN-GWEXERs that are adjacent to each other (whether they are adjacent on the same floor or whether they are adjacent on top of/below each other by virtue of being installed in the same location on different floors). See Crestron's [[RF Products Best Practices guide>>https://www.crestron.com/getmedia/3b3588d1-9356-4d4b-a2df-b3ac1c6fff14/mg_bp_installation_setup_crestron_rf_products]] for more details on RF channel selection. 54 54 55 -= Acquiring Devices = 71 +* If using Text Console, run the command: ##rfchannel [#]## 72 +** Replace "[#]" with the desired RF channel 73 +* If using the Gateway Configuration tool: 74 +** Connect to the CEN-GWEXER in another tool such as Text Console 75 +** Navigate to Functions > Gateway Configuration... to open the tool 76 +** At the top left, under "RF Channel", ensure "Fixed" is selected and then choose a channel 77 +** The Gateway Configuration window will become nonresponsive while the RF channel is being applied to the gateway 78 +** Close the tool once the change has been applied 79 +* Once the RF channel has been updated, verify it by running the command: ##rfchannel## without any parameters 56 56 57 -~/~/1-2-3-hold on 4 until all lights blink, then release 58 -top light will blink slowly a few times and then hold solid or start blinking rapidly 59 -if rapid blinking, cancel acquire and make sure that rf gateway is in acquire mode and device is in range then repeat to put device into acquire mode 81 += Acquiring and Addressing Devices = 60 60 61 -== Text Console == 83 +(% class="box warningmessage" %) 84 +((( 85 +**When acquiring wireless hardware on jobs with multiple CEN-GWEXERs, it is very important that only one gateway is in acquire mode at a time.** 86 +Once you are done acquiring devices to one gateway, ensure that you take the gateway out of acquire mode before you begin acquiring devices to the next gateway. 87 +Attempting to acquire devices while multiple gateways are actively in acquire mode may result in wireless hardware being acquired to the incorrect gateway. 88 +))) 62 62 63 - ~/~/"acquire start"and"acquire stop"90 +Unlike wired Cresnet devices such as DIN-CENCN-2s or processors which can poll the connected Cresnet and report all devices that are currently connected, CEN-GWEXERs and other wireless gateways must first acquire the wireless Crestron devices. Acquiring wireless Crestron devices involves putting the gateway into acquire mode and then performing a physical button press sequence on each of the wireless devices to be acquired. This process is described in detail below: 64 64 65 -~/~/"rep" to show acquired devices 92 +* Put the CEN-GWEXER into acquire mode using one of the methods below: 93 +** If using Text Console, run the command: ##acquire start## 94 +*** Devices will indicate their TSID in the Text Console window as they are acquired 95 +** If using the Gateway Configuration tool: 96 +*** Connect to the CEN-GWEXER in another tool such as Text Console 97 +*** Navigate to Functions > Gateway Configuration... to open the tool 98 +*** At the bottom left, click "Start Acquire" 99 +*** [[image:1701720163760-996.png||height="271" width="316"]] 100 +*** Wait for the confirmation dialog and click "OK" to close the confirmation dialog 101 +*** Previously acquired devices will be displayed with black text, while newly acquired devices will populate with blue text 102 +*** Using the Gateway Configuration tool to acquire hardware may be preferable to using Text Console as acquired devices will report their Serial Number as they are acquired instead of just their TSID 103 +* The process for acquiring a wireless device to a gateway varies for each model, but generally the procedure is as follows: 104 +** Press the "setup" button (top button for keypads) in the sequence press-press-press-hold 105 +** Do not release the button until the setup LED (top feedback LED for keypads) begins blinking slowly 106 +*** If the setup LED turns steady, then the device was acquired successfully 107 +*** If the setup LED begins to rapidly blink, then the acquire failed 108 +**** Press the "setup" button again to cancel acquire 109 +**** Attempt to acquire the device again 110 +**** If the device fails to acquire a second time: verify that the correct gateway is in acquire mode, verify that no other gateways are in acquire mode, verify that the desired gateway is close enough to the device that it should be able to acquire, and verify that there are no other sources of RF interference that may be preventing acquisition. 111 +** Repeat for all wireless devices that need to be acquired to the gateway 112 +* Once all devices have been acquired, take the CEN-GWEXER out of acquire mode: 113 +** If using Text Console, run the command: ##acquire stop## 114 +** If using the Gateway Configuration tool, click the "STOP Acquire" button in the lower left 115 +* Address devices as indicated in the SHOWRUNNER™ takeoff by either: 116 +** Use Text Console to run the command: ##setrfidbytsid [CID] [TSID]## 117 +*** Replace "[CID]" with the connection ID as indicated in the takeoff 118 +*** Replace "[TSID]" with the 4-byte, hexadecimal TSID of the device to be addressed 119 +** Use Network Device Tree View to select each device and address them individually 120 +* Verify all devices have been acquired and addressed correctly using Network Device Tree View or with the Text Console command: ##reportnetdev## 66 66 67 -== Gateway Configuration Tool == 68 - 69 -~/~/Connect > functions > gateway configuration for better acquiring tool 70 - 71 71 = Moving/Removing Devices (Unacquiring Devices) = 72 72 73 73 When a wireless Crestron device is acquired to a new gateway using the typical acquiring process described above, it will automatically forget the previously connected gateway. The gateway itself, however, must manually "forget" the previously connected device before a newly acquired and addressed device will function correctly. This is necessary whether the originally connected device is moved or if the originally corrected device has failed and is being replaced.