Changes for page UDP Input
Last modified by Alexander Mott on 2025/10/01 17:30
From version 10.1
edited by Alexander Mott
on 2025/10/01 17:10
on 2025/10/01 17:10
Change comment:
There is no comment for this version
To version 3.3
edited by Mark Kohlmann
on 2021/12/08 21:05
on 2021/12/08 21:05
Change comment:
Update document after refactoring.
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,52 +1,37 @@ 1 -ShowRunner CLC™can accept commands via UDP. Feedback is not provided.1 +ShowRunner can accept commands via UDP. Feedback is not provided. 2 2 3 -Enable the TCP listener by specifying a port and the max connections via the console: 4 -##sr udp enable (ListenPort)## 5 -Example: 6 -##sr udp enable 45794 20## 7 -The UDP Listener may also be enabled by adding a snippet to the root of the config: 8 -(% class="box" %) 9 -((( 10 -##"UdpListener": 3 +Enable the UDP listener by specifying a port in the config: 4 + 5 +## "UdpListener": 11 11 { 12 12 "ListenPort": 45794 13 13 },## 14 -))) 15 15 16 -Commands are sent to objects by GlobalId followed by the Action and then any relevant Properties (Properties are interpreted in the order shown). They are dot delimited and terminated with a carriage return. 10 +Commands are sent to objects by GlobalId followed by the Action and then any relevant Properties (Properties are interpreted in the order shown). They are dot delimited and terminated with a carriage return. 17 17 Format: ##GlobalId.ActionName[.ActionPropertyValue]\x0D## 18 18 19 19 To obtain a list of GlobalIds for objects use console command ##sr show global ids##. Global Actions use a GlobalId of 0. 20 20 21 -To obtain a list of Actions available by object type use console command ##sr show actions##. The table below includes all of the available Actions available as of ShowRunnerCLC™ version 3.019, but it is possible additional actions have been added since and it is always best to run this command on the installed processor to get version-specific actions. 22 -\\An example of a UDP command follows the actions table. 15 +To obtain a list of Actions available by object type use console command ##sr show actions##. 23 23 24 - {{display reference="SHOWRUNNER™User Guide & Wiki.SHOWRUNNER™ KeypadTypes.WebHome" section="HShowRunnerCLC2122ActionsTable"/}}17 +Example Recall Scene 1 on Area 51: 25 25 26 - 27 -(% class="box" %) 28 -((( 29 -Example to Recall Scene 1 on Area with Global Id 51: 30 - 31 - 32 32 From "sr show global ids": 20 + 33 33 ##+~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 34 34 ~| ID | Type | Name | 35 35 +~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 36 36 ~| 51 | Area | Boardroom A |## 37 37 ##+~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+## 26 + 38 38 From "sr show actions": 28 + 39 39 ##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 40 40 ~| Type | Action | Description | Reference Property | Ref Req | Triggers | Supported Properties | 41 41 +~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 42 -~| Area | RecallScene | Recalls the specified scene on this load | SceneId | False | Digital, Analog | 'SceneId' {{{:}}}(Integer)'Scene Number to recall' |32 +~| Area | RecallScene | Recalls the specified scene on this load | SceneId | False | Digital, Analog | 'SceneId':(Integer)'Scene Number to recall' | 43 43 +~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~--+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+## 44 44 45 - 46 46 UDP Command to send: 47 -##51.RecallScene.1\x0D## 48 -))) 49 49 50 - 51 - 52 - 37 +51.RecallScene.1\x0D