Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 6.1
edited by Mark Kohlmann
on 2021/02/10 20:09
on 2021/02/10 20:09
Change comment:
There is no comment for this version
To version 8.1
edited by Mark Kohlmann
on 2021/06/16 17:40
on 2021/06/16 17:40
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,17 +11,23 @@ 11 11 )))|250 12 12 |((( 13 13 * DIN-AP3 14 +* DIN-AP4 14 14 * DIN-AP3MEX 15 15 * MC3 (Not Supported by SR) 16 16 * RMC3 18 +* RMC4 17 17 )))|500 18 18 |((( 19 19 * CP3 22 +* CP4 20 20 * CP3N 24 +* CP4N 21 21 )))|1000 22 22 |((( 23 23 * AV3 28 +* AV4 24 24 * PRO3 30 +* PRO4 25 25 )))|2000 26 26 27 27 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] ... ... @@ -30,16 +30,16 @@ 30 30 31 31 AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 32 32 33 -|=Feature|=Type|=Point|=Label|=R/W|=Units 34 -|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 -|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 -|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 -|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 -|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 39 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 40 +|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 41 +|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 42 +|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 43 +|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 44 +|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 39 39 40 40 === Zum Floor Hub BACnet Point Emulation === 41 41 42 -ShowRunner can emulate the Zum Floor Hubs BACnet points. 48 +ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode. Each point may be enabled/disabled individually by Area. 43 43 44 44 Set the following Area properties: 45 45