Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 6.1
edited by Mark Kohlmann
on 2021/02/10 20:09
on 2021/02/10 20:09
Change comment:
There is no comment for this version
To version 31.1
edited by Alexander Mott
on 2024/06/14 18:19
on 2024/06/14 18:19
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -ShowRunner BACnet 1 +ShowRunnerCLC™ BACnet - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ User Guide& Wiki.SHOWRUNNER™ Appendix.WebHome1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,8 +1,20 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limit s. ShowRunner's BACnet featureis licensed.NETlicense.More than 50 points require the Crestron paid licenseand totalpoints are limitedbytheplatform.The processor itself consumes a point.1 +ShowRunnerCLC™ uses Crestron's BACnet/IP stack and is bound by its licensing and limitations. Integrations of 50 points or less may use the free Crestron BACnet license, while integrations with more than 50 points require the Crestron paid license (ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable ShowRunnerCLC™ installation on the processor). The maximum number of BACnet points available is limited per processor and detailed in the table below (note that the processor itself consumes a point). 2 2 3 +ShowRunnerCLC™'s BACnet feature is licensed, and an additional license from Chief Integrations is required. BACnet points are automatically created and assigned during commissioning, and a .csv export of the points may be downloaded from the system. It is recommended to wait until after ShowRunnerCLC™ has been fully started up to provide BACnet points to third parties as changes to the ShowRunnerCLC™ program made during start-up may affect the names and IDs for automatically generated BACnet points. 4 + 5 +ShowRunnerCLC™ version 3.050 and newer includes support for fully customized BACnet points, but it is labor intensive to implement. Discuss with Chief Integrations if you believe your job requires custom BACnet points (e.g. upgrading a non-ShowRunnerCLC™ system with existing BACnet integrations to ShowRunnerCLC™). 6 + 7 +BACnet Stack Features: 8 + 9 +* BACnet/IP 10 +* Configurable BACnet UDP port (options may be limited by processor firmware) 11 +* BBMD w/ Foreign Device Registration (Enabled if necessary) 12 +* Points can be discovered using traditional BACnet discovery tools 13 +* ShowRunnerCLC™ version 3.050 and later support custom BACnet points. Please discuss with Chief Integrations. 14 + 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Objects17 +|=Control System|=Max # of Points 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -11,41 +11,71 @@ 11 11 )))|250 12 12 |((( 13 13 * DIN-AP3 26 +* DIN-AP4 14 14 * DIN-AP3MEX 15 15 * MC3 (Not Supported by SR) 29 +* MC4 16 16 * RMC3 31 +* RMC4 17 17 )))|500 18 18 |((( 19 19 * CP3 35 +* CP4 20 20 * CP3N 37 +* CP4N 21 21 )))|1000 22 22 |((( 23 23 * AV3 41 +* AV4 24 24 * PRO3 43 +* PRO4 25 25 )))|2000 45 +|((( 46 +* ZUM-HUB4 47 +)))|9,000 26 26 27 27 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 28 28 29 -=== ShowRunner BAC NETPoints ===51 +=== ShowRunnerCLC™ BACnet Points === 30 30 31 -Area BaseIDsare assigned automaticallyand maintained.Pointsare discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode.53 +==== Area BACnet Points ==== 32 32 33 -|=Feature|=Type|=Point|=Label|=R/W|=Units 34 -|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 -|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 -|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 -|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 -|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 55 +Provides control/status for a single area within ShowRunnerCLC™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunnerCLC™ BACnet mode. 39 39 40 -=== Zum Floor Hub BACnet Point Emulation === 57 +{{{Offset is 1000 in configs generated in ShowRunner 3.30 or newer (V2 definition). Offset is 10000 in older configs or using V1 definition. 58 +AreaBaseID = BACnetIndex * Offset}}} 41 41 42 -ShowRunner can emulate the Zum Floor Hubs BACnet points. 60 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 61 +|Area Scene|Current Scene Active on the Area / Change Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 62 +|Occupancy Mode|Current Occupancy Mode for the Area / Change Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 63 +|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 64 +|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 65 +|Area Power|Current Area Power Consumption in Watts (Requires SR EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 66 +|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + (V2: 100, V1: 1000) + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 67 +|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + (V2: 50, V1: 100) + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 43 43 69 +==== Global BACnet Points ==== 70 + 71 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 72 +|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 73 +|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 74 +|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 75 +1: Normal 76 +2: After Hours 77 +))) 78 +|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 79 +|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 80 + 81 +=== Zūm Floor Hub BACnet Point Emulation === 82 + 83 +ShowRunnerCLC™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard ShowRunnerCLC™ mode. Each point may be enabled/disabled individually by Area. ShowRunner does not expose every point per area that the Zum Hub does, just the points listed below are exposed. 84 + 44 44 Set the following Area properties: 45 45 46 -{{{BACnetIndex: (ID of the Room, this number of multiplied times2048 to get the BACnet points, start at 1)47 -BACnetMode: "ZumEmulation" }}}87 +{{{BACnetIndex: (ID of the Room, this number of multiplied by 2048 to get the BACnet points, starts at 1) 88 +BACnetMode: "ZumEmulation" 48 48 90 +AreaBaseID = BACnetIndex * 2048}}} 49 49 50 50 |=Feature|=(% style="width: 149px;" %)Type|=(% style="width: 341px;" %)Point|=Label|=Description|=R/W|=Units 51 51 |Area Scene|(% style="width:149px" %)MV|(% style="width:341px" %)AreaBaseID + 8|{AreaName}>{AreaId}>ActiveScene>BI|View or change the current scene. Off scene is 17, Scenes 1 through 16 depend on area configuration.|RW|Scene ... ... @@ -54,4 +54,5 @@ 54 54 |Online|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID|{AreaName}>{AreaId}>RoomOnline>BI|Current room online state, this is fixed as true.|R|Boolean 55 55 |On|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID + 1|{AreaName}>{AreaId}>RoomOn>BI|Current room load state. If any load is on this will be true.|R|Boolean 56 56 57 -{{{AreaBaseID = BACnetIndex * 2048}}} 99 +{{{ 100 + }}}