Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 19.1
edited by Mark Kohlmann
on 2022/06/10 16:17
on 2022/06/10 16:17
Change comment:
There is no comment for this version
To version 6.1
edited by Mark Kohlmann
on 2021/02/10 20:09
on 2021/02/10 20:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Content
-
... ... @@ -1,14 +1,8 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed , a license from Chief Integrations is required. Integrations of 50 points or less may use the free Crestron BACnetlicense. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point.BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system.1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. 2 2 3 -BACnet Stack Features: 4 - 5 -* Configurable BACnet port 6 -* BBMD w/ Foreign Device Registration (Enabled if necessary) 7 -* Points can be discovered using traditional BACnet discovery tools 8 - 9 9 === Crestron BACnet Stack Details === 10 10 11 -|=Control System|=Max # of Points5 +|=Control System|=Max # of Objects 12 12 |((( 13 13 * FT-TSC600 (Not Supported by SR) 14 14 * TPCS-4SM (Not Supported by SR) ... ... @@ -17,58 +17,35 @@ 17 17 )))|250 18 18 |((( 19 19 * DIN-AP3 20 -* DIN-AP4 21 21 * DIN-AP3MEX 22 22 * MC3 (Not Supported by SR) 23 -* MC4 24 24 * RMC3 25 -* RMC4 26 26 )))|500 27 27 |((( 28 28 * CP3 29 -* CP4 30 30 * CP3N 31 -* CP4N 32 32 )))|1000 33 33 |((( 34 34 * AV3 35 -* AV4 36 36 * PRO3 37 -* PRO4 38 38 )))|2000 39 39 40 40 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 41 41 42 -=== ShowRunner BAC netPoints ===29 +=== ShowRunner BACNET Points === 43 43 44 - ====AreaACnet Points====31 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 45 45 46 -Provides control/status for a single area within ShowRunner. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 33 +|=Feature|=Type|=Point|=Label|=R/W|=Units 34 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 47 47 48 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 49 -|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 50 -|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 51 -|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 52 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 53 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 54 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 55 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 56 - 57 -==== Global BACnet Points ==== 58 - 59 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 60 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 61 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 62 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 63 -1: Normal 64 -2: After Hours 65 -))) 66 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 67 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 68 - 69 69 === Zum Floor Hub BACnet Point Emulation === 70 70 71 -ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode.Each point may be enabled/disabled individually by Area.42 +ShowRunner can emulate the Zum Floor Hubs BACnet points. 72 72 73 73 Set the following Area properties: 74 74