Changes for page DMX Input via Pharos

Last modified by Alexander Mott on 2024/06/14 18:25

From version 10.1
edited by Alexander Mott
on 2024/06/14 18:25
Change comment: There is no comment for this version
To version 8.1
edited by Mark Kohlmann
on 2022/06/09 16:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,23 +1,20 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into ShowRunnerCLC™.  [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient.
3 +Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into showrunner.  [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient.
4 4  )))
5 5  
6 -ShowRunnerCLC™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using more than 50 channels on the DMX input.  Use as few channels as possible and try not to send fades over DMX into the Pharos.
6 +SHOWRUNNER™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using more than 50 channels on the DMX input.  Use as few channels as possible and try not to send fades over DMX into the Pharos.
7 7  
8 8  Steps:
9 9  
10 -ShowRunnerCLC
10 +SHOWRUNNER
11 11  
12 -1. Enable [[UDP Listener>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.UDP Input.WebHome]] in the ShowRunnerCLC™ config:
12 +1. Enable [[UDP Listener>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.UDP Input.WebHome]] in the SHOWRUNNER™ config:
13 13  
14 -(% class="box" %)
15 -(((
16 -## "UdpListener":
17 - {
18 - "ListenPort": 45794
19 - },##
20 -)))
14 + "UdpListener":
15 + {
16 + "ListenPort": 45794
17 + },
21 21  
22 22  Pharos Config:
23 23  
... ... @@ -25,17 +25,17 @@
25 25  1. Go to Project->Project Features and set DMX In under Trigger to Enabled
26 26  1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input
27 27  1. Triggers
28 -11. Create a trigger on each DMX Input that you wish to send to ShowRunnerCLC
25 +11. Create a trigger on each DMX Input that you wish to send to SHOWRUNNER
29 29  11. Set Trigger Parameters:
30 30  111. Channel: Channel # you wish to capture
31 31  111. Changes in range: Minimum: 0 Maximum: 255
32 32  11. New Action: Output Ethernet
33 33  111. Enable Variables
34 -111. IP/Hostname: IP Address or Hostname of the processor running ShowRunnerCLC
31 +111. IP/Hostname: IP Address or Hostname of the processor running SHOWRUNNER
35 35  111. Port: 45794
36 36  111. Protocol: UDP
37 37  111. String: "GID.SetLevelByByte.<3>\r"
38 -1111. GID is the GlobalID for the load within ShowRunnerCLC
35 +1111. GID is the GlobalID for the load within SHOWRUNNER
39 39  111. Example DMX Channel 41 controlling load with global ID of 32:
40 40  [[image:1597260805025-107.png||height="58" width="693"]]
41 41