Changes for page DMX Input via Pharos
Last modified by Alexander Mott on 2024/06/14 18:25
From version 10.1
edited by Alexander Mott
on 2024/06/14 18:25
on 2024/06/14 18:25
Change comment:
There is no comment for this version
To version 2.1
edited by Mark Kohlmann
on 2020/08/12 19:33
on 2020/08/12 19:33
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,23 +1,15 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -Note: This should only be used if there is no ability to generate an e-DMX (sACN/Art-Net) feed into ShowRunnerCLC™. [[E-DMX receiver>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.sACN and ArtNet Receive.WebHome]] is much more efficient. 4 -))) 1 +SHOWRUNNER™ can accept commands from a Pharos' DMX input. Note: Pharos recommends not using anymore than 50 channels on the DMX input. 5 5 6 -ShowRunnerCLC™ can accept commands from a Pharos' DMX input. Note: Pharos recommends not using more than 50 channels on the DMX input. Use as few channels as possible and try not to send fades over DMX into the Pharos. 7 - 8 8 Steps: 9 9 10 -S howRunnerCLC™5 +SHOWRUNNER™ 11 11 12 -1. Enable [[UDP Listener>>doc:SHOWRUNNER™Integrations Guide.Integration Options.UDP Input.WebHome]] in the ShowRunnerCLC™config:7 +1. Enable UDP Listener in the SHOWRUNNER™ config: 13 13 14 -(% class="box" %) 15 -((( 16 -## "UdpListener": 17 - { 18 - "ListenPort": 45794 19 - },## 20 -))) 9 + "UdpListener": 10 + { 11 + "ListenPort": 45794 12 + }, 21 21 22 22 Pharos Config: 23 23 ... ... @@ -25,17 +25,17 @@ 25 25 1. Go to Project->Project Features and set DMX In under Trigger to Enabled 26 26 1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input 27 27 1. Triggers 28 -11. Create a trigger on each DMX Input that you wish to send to S howRunnerCLC™20 +11. Create a trigger on each DMX Input that you wish to send to SHOWRUNNER™ 29 29 11. Set Trigger Parameters: 30 30 111. Channel: Channel # you wish to capture 31 31 111. Changes in range: Minimum: 0 Maximum: 255 32 32 11. New Action: Output Ethernet 33 33 111. Enable Variables 34 -111. IP/Hostname: IP Address or Hostname of the processor running S howRunnerCLC™26 +111. IP/Hostname: IP Address or Hostname of the processor running SHOWRUNNER™ 35 35 111. Port: 45794 36 36 111. Protocol: UDP 37 37 111. String: "GID.SetLevelByByte.<3>\r" 38 -1111. GID is the GlobalID for the load within S howRunnerCLC™30 +1111. GID is the GlobalID for the load within SHOWRUNNER™ 39 39 111. Example DMX Channel 41 controlling load with global ID of 32: 40 40 [[image:1597260805025-107.png||height="58" width="693"]] 41 41