1 +SHOWRUNNER™ can accept commands from a Pharos' DMX input.  Note: Pharos recommends not using anymore than 50 channels on the DMX input.
2 +
3 +Steps:
4 +
5 +SHOWRUNNER™
6 +
7 +1. Enable [[UDP Listener>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.Integration Options.UDP Input.WebHome]] in the SHOWRUNNER™ config:
8 +
9 + "UdpListener":
10 + {
11 + "ListenPort": 45794
12 + },
13 +
14 +Pharos Config:
15 +
16 +1. Create a new Pharos Project or Open an Existing One
17 +1. Go to Project->Project Features and set DMX In under Trigger to Enabled
18 +1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input
19 +1. Triggers
20 +11. Create a trigger on each DMX Input that you wish to send to SHOWRUNNER™
21 +11. Set Trigger Parameters:
22 +111. Channel: Channel # you wish to capture
23 +111. Changes in range: Minimum: 0 Maximum: 255
24 +11. New Action: Output Ethernet
25 +111. Enable Variables
26 +111. IP/Hostname: IP Address or Hostname of the processor running SHOWRUNNER™
27 +111. Port: 45794
28 +111. Protocol: UDP
29 +111. String: "GID.SetLevelByByte.<3>\r"
30 +1111. GID is the GlobalID for the load within SHOWRUNNER™
31 +111. Example DMX Channel 41 controlling load with global ID of 32:
32 +[[image:1597260805025-107.png||height="58" width="693"]]