Changes for page CoAP ShowRunner to ShowRunnerCLC™ Setup Instructions
Last modified by Alexander Mott on 2023/07/07 15:17
From version 12.2
edited by Craig Lewis
on 2021/09/22 22:16
on 2021/09/22 22:16
Change comment:
There is no comment for this version
To version 29.1
edited by Alexander Mott
on 2022/11/17 16:58
on 2022/11/17 16:58
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ User Guide& Wiki.SHOWRUNNER™ Appendix.Integration Options.CoAP with Crestron S# Library and Modules.WebHome1 +SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,24 +1,71 @@ 1 -===== Host processor(LWAPIServer)Setup (DIN-AP3@ 10.44.5.91)=====1 +===== Use ShowRunner version 3.010 or later ===== 2 2 3 +Terminology: 4 + 5 +* Client Processor - Processor that will interact with hardware attached to the host procesor. 6 +* CWS - Crestron Web Server, the processor's internal web server 7 +* Host Processor (Server) - Processor that hosts the physical hardware 8 +* LWAPI - Lightweight API (CoAP) 9 +* User Page Auth - Requires a username and password to access the internal web server (CWS) on the processor. 3-series always has this enabled if authentication is activated. 4-series processors have an option to have user page auth on or not (default is off). 10 + 11 +Steps: 12 + 13 +1. [[Setup Host Processor>>WebHome||anchor="Host processor (LWAPI Server) Setup (DIN-AP3 @ 10.44.5.91)"]] 14 +11. Verify processor configuration 15 +11. Verify LWAPI is enabled 16 +11. Create API User 17 +11. Create CWS User (if necessary) 18 +11. Save the configuration 19 +1. [[Setup Client Processor>>WebHome||anchor="Client processor (LWAPI Client) Setup (DIN-AP4) Version 3.011 or newer"]] 20 +11. Define the remote system 21 +11. Setup auth for the remote system 22 +11. Save the configuration 23 +1. Verify successful communications with the following commands: 24 +11. On host, verify the client shows up as a web session: ##sradmin sh web sess## 25 +11. On client, verify the session with the host: ##sr sh lwapi cli br## 26 + 27 +===== Host processor (LWAPI Server) Setup (e.g. DIN-AP3 @ 10.44.5.91) ===== 28 + 3 3 Steps 1-3 and 5 always needed. 4 4 5 5 1. If 3-series, Enable Authentication [##authentication on##] or SSL [##ssl self##] if not already enabled. 4-Series have authentication enabled by default. User Page Auth should be turned off on 4-series. 6 -1. Enable LWAPI In Config (@ root level): 32 +1. Enable LWAPI 33 +From Console (v 3.011 or later; processor will automatically restart): 34 +## sr lwapi enable true## 35 +In Config (@ root level; reloading the configuration is required): 7 7 ## "LwApiEnable": true, 8 8 "LwApiSecurityLevel": "Auth",## 9 -1. Create an API User and record the Key and Secret. User group must have //LWAPI //role and //Execute //permissions. //Lightweight API Users// group has been created for this purpose: 38 +1. Create an API User and record the Key and Secret. User group must have //LWAPI //role and //Execute //permissions. This allows the //Lightweight API Users// group has been created for this purpose: 10 10 ##DIN-AP3>sradmin add api user "Central Control" "Lightweight API Users" 11 11 API User Central Control generated with Group permissions Lightweight API Users and Key: (% style="color:blue" %)**YTd2pQn7sjwiOWD9NqCIWw**(%%) Secret: (% style="color:orange" %)**OeiQEFo_-EDfc7sQe_qRpeQzSkZjylV2roa76utpJLI**(%%)## 12 - 13 -1. If 3-series w/ auth enabled or 4-series with user page auth enabled then add a remote user with permissions to connect to the control system. This is done by adding a local user to the system with connect privileges. Sample values shown, do not re-use these. 41 +1. If 3-series w/ auth enabled or 4-series with user page auth enabled then add a remote user with permissions to connect to the control system. This is done by adding a local user to the system with user privileges. Sample values shown, do not re-use these. 14 14 ##DIN-AP3>adduser -N:(% style="color:purple" %)**lwapi**(%%) -P:(% style="color:darkgoldenrod" %)**dMFN9pJJXjWLGd7t**(%%) 15 15 User account was successfully created. 16 -DIN-AP3>addusertogroup -N:lwapi -G: Connects17 -'lwapi' was successfully added to group ' Connects'.##44 +DIN-AP3>addusertogroup -N:lwapi -G:Users 45 +'lwapi' was successfully added to group 'Users'.## 18 18 1. Save the configuration 19 19 20 -===== Client processor (LWAPI Client) Setup (DIN-AP4) ===== 48 +===== Client processor (LWAPI Client) Setup (e.g. DIN-AP4) Version 3.011 or newer ===== 21 21 50 +Steps 1-3 always needed. **Note:** host and client processors must be able to communicate with each other to use this method (i.e. the network must be configured and both processors must have SHOWRUNNER™ program and configuration loaded). 51 + 52 +1. Define remote system in the config: 53 +## { 54 + "SystemId": (% style="color:darkcyan" %)1(%%), 55 + "IpAddressOrHostname": "10.44.5.91", 56 + "Label": "HUB-1-1", 57 + "ConnectionType": "LWAPI" 58 + },## 59 +1. Add Users : 60 +if CWS User is not needed: 61 +##DIN-AP4>sr remote system auth (% style="color:darkcyan" %)**1**(%%) (% style="color:blue" %)**YTd2pQn7sjwiOWD9NqCIWw**(%%) (% style="color:orange" %)**OeiQEFo_-EDfc7sQe_qRpeQzSkZjylV2roa76utpJLI**(%%)## 62 +if CWS User is needed: 63 +##DIN-AP4>sr remote system auth (% style="color:darkcyan" %)**1**(%%) (% style="color:blue" %)**YTd2pQn7sjwiOWD9NqCIWw**(%%) (% style="color:orange" %)**OeiQEFo_-EDfc7sQe_qRpeQzSkZjylV2roa76utpJLI **(% style="color:purple" %)**lwapi**(%%)** (% style="color:darkgoldenrod" %)dMFN9pJJXjWLGd7t(%%)** 64 +Success## 65 +1. Save the configuration 66 + 67 +===== Client processor (LWAPI Client) Setup (e.g. DIN-AP4) Version 3.010 or earlier ===== 68 + 22 22 Steps 1-3 and 6 always needed. 23 23 24 24 1. Define remote system in the config: