Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 3.20
edited by Mark Kohlmann
on 2020/04/14 20:59
on 2020/04/14 20:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,7 +21,7 @@ 21 21 )))|Crestron SmartGraphics XPanel 22 22 HTML5 UI Under Development (Q4 2020)|SHOWRUNNER™ - Crestron SmartGraphics XPanel 23 23 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 -|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y *24 +|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y, Physical Presence in Room Required 25 25 |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N 26 26 |(% colspan="6" %)**Features** 27 27 |Scene Recall|Y|Y|Y|Y|Y ... ... @@ -31,71 +31,9 @@ 31 31 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 32 32 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 33 33 |Override Occupancy Logic|Y|Y|N|N|N 34 -|Plug Load On/Off|Y|Y| Y|Y|ByHardware34 +|Plug Load On/Off|Y|Y| | | 35 35 |Integration with Non-Zūm Hardware|Y|Y|N|N|N 36 -|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware 37 -|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 38 -Floor Hub: 6-12 months|6-12 months|6-12 months 39 -|(% colspan="6" %)**Calendar/Scheduling** 40 -|Logic Type|Event Driven 41 -Profile Support (Under Development)|Event Driven 42 -Profile Support (Under Development)|SHOWRUNNER™: Event Driven 43 -Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 44 -|Astronomical Clock|Y|Y|Y|Y|N/A 45 -|Holidays|Pattern|Pattern|SHOWRUNNER™: Pattern 46 -Floor Hub: Hard Coded|Hard Coded|N/A 47 -|Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 48 -Floor Hub: N|N|N/A 49 -|(% colspan="6" %)**Integrations** 50 -|A/V Integration: API|Y|Y|SHOWRUNNER™: Y 51 -Floor Hub: Limited|Limited|N/A 52 -|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y 53 -Floor Hub: N|N|N/A 54 -|A/V Integration: RS-232|Y|Y|((( 55 -SHOWRUNNER™: Y 56 -Floor Hub: AVBRIDGE per Area 57 -)))|AVBRIDGE per Area|N/A 58 -|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 59 -SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 60 -Floor Hub: Y 61 -)))|Y|N/A 62 -|BACNET Features|((( 63 -Per Area Status: 64 -Active Scene 65 -Occupied 66 -Occupancy Enabled 67 -Individual Load Level 68 -Photocell Level (per Photocell) 36 +|Custom Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware 69 69 70 -System: 71 -Demand Response Enabled 72 -System Wide Override (Panic/Emergency) 73 -)))|See list for SHOWRUNNER™ Total Control|((( 74 -SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 75 -Floor Hub: See list for ZUM-FLOOR-HUB 76 -)))|((( 77 -Per Room Status: 78 -Online 79 -On 80 -Occupied 81 -Daylighting Active 82 -Device Battery is Low 83 -Plug Loads Enabled 84 -Occupancy Sensor Enabled 85 -Current Daylight Level 86 -Active Scene 87 -\\System: 88 -Demand Response Enabled 89 -)))|N/A 90 -|BACNET Settings Scope|Per Area|Per Area|((( 91 -SHOWRUNNER™: Per Area 92 -Floor Hub: Global 93 -)))|Global|N/A 94 -|Crestron Fusion|Y|Y|((( 95 -SHOWRUNNER™: Y 96 -Floor Hub: N 97 -)))|N|N/A 98 -| | | | | | 99 - 100 100 ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 101 101 ##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).##