Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 27.1
edited by Mark Kohlmann
on 2021/04/12 17:44
on 2021/04/12 17:44
Change comment:
There is no comment for this version
To version 32.1
edited by Mark Kohlmann
on 2021/07/26 18:04
on 2021/07/26 18:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -36,7 +36,11 @@ 36 36 |Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner|N|N/A 37 37 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 38 38 |Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 39 -|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 39 +|Custom Zūm Keypad Programming|((( 40 +Y, per individual button (1 through 4) 41 +AV Keypad not required (v3.004 or later) 42 +[[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]] 43 +)))|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 40 40 |New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 41 41 Floor Hub: 6-12 months|6-12 months|6-12 months 42 42 |Room Organization|((( ... ... @@ -127,8 +127,8 @@ 127 127 SHOWRUNNER™: Y 128 128 Floor Hub: N 129 129 )))|N|N/A 130 -|Minimum NETBRIDGE Firmware|v1.1 2.0130 (PUF Zum MESHNET v1.06.09)|v1.010|N/A|See Crestron|See Crestron131 -|Minimum Gateway Firmware|v1.4469.000 11|N/A|N/A|See Crestron|See Crestron134 +|Minimum NETBRIDGE Firmware|v1.13.0020 (PUF Zum MESHNET v1.07.16)|v1.010|N/A|See Crestron|See Crestron 135 +|Minimum Gateway Firmware|v1.4469.00022|N/A|N/A|See Crestron|See Crestron 132 132 |Minimum SHOWRUNNER™ Version|2.198|2.198|N/A|N/A|N/A 133 133 134 134 {{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App. ... ... @@ -135,8 +135,8 @@ 135 135 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 136 136 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 137 137 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 138 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 139 -****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors. 142 +***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. Sometimes delays in sending load levels occur. Feature is primarily intended for remotely setting scenes. 143 +****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors and recall scene 15. The occupancy sensor enabled state and current scene will be remembered and recalled when leaving occupancy mode. 140 140 }}} 141 141 142 142 {{id name="caveats"/}}