Changes for page Crestron Zūm Wireless

Last modified by Scott Kohlmann on 2023/04/20 22:28

From version 17.1
edited by Mark Kohlmann
on 2020/11/10 18:58
Change comment: There is no comment for this version
To version 14.1
edited by Mark Kohlmann
on 2020/04/15 16:43
Change comment: Uploaded new attachment "ZumApp@2x.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -15,7 +15,7 @@
15 15  |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A
16 16  |Requires Dedicated RS-232 Serial Port per Room|N|Y|N|N|N/A
17 17  |Requires 3 or 4-Series Control System|Y|Y|Y|N|N/A
18 -|Requires Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y
18 +|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y
19 19  |(% colspan="6" %)**User Interfaces**
20 20  |Web Browser|(((
21 21  Crestron SmartGraphics XPanel
... ... @@ -26,10 +26,10 @@
26 26  |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
27 27  |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N
28 28  |(% colspan="6" %)**Features**
29 -|Scene Recall|Y ~*~*~*~*|Y ~*~*~*~*|Y|Y|Y
30 -|Override Fade Time for Scene Recall ~*~*|Y|N|N|N|N
31 -|Scene Save|Y ~*~*~*~*|Y ~*~*~*~*|N|N|Y
32 -|Load Control|Y ~*~**|Y ~*~**|N|N|Y
29 +|Scene Recall|Y|Y|Y|Y|Y
30 +|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N
31 +|Scene Save|Y|Y|N|N|Y
32 +|Load Control|Y|Y|N|N|Y
33 33  |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N
34 34  |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y
35 35  |Override Occupancy Logic|Y|Y|N|N|N
... ... @@ -127,48 +127,32 @@
127 127  Floor Hub: N
128 128  )))|N|N/A
129 129  
130 -{{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.
131 -** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).
132 -*** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer.
133 -**** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time.
134 -}}}
130 +##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
131 +##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##
135 135  
136 -==== Caveats ====
137 137  
138 -* Zum Wireless has an internal rate limit that will shutdown communication if a number of commands are received in a short period of time.  This can be seen when repeatedly pressing buttons on a keypad as well as repeatedly triggering actions from ShowRunner.
139 -* Raise/Lower operations from ShowRunner cannot track directly with the load response, see ~*~** above.  ShowRunner will poll the NETBRIDGE for current levels ~~3 seconds after the raise/lower is stopped to obtain current load levels.
140 -* Lower operations can turn the load off.  The load will not come on with a raise.  This is a firmware behavior in the Zum hardware.
141 -* Wireless control presents some additional latency possibilities.  Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load.  Local operation of the Zum wireless room is not impacted.
142 -
143 -(% id="HTopologies" %)
144 144  ==== Topologies ====
145 145  
146 -(% class="box" %)
147 -(((
148 148  **SHOWRUNNER™ Total Control**
137 +
149 149  [[image:ZumSr\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology"]]
150 -)))
151 151  
152 -(% class="box" %)
153 -(((
140 +
154 154  **SHOWRUNNER™ + AVBRIDGE + Serial Port**
142 +
155 155  [[image:ZumAvbSr\@2x.png||alt="Zum AVBRIDGE + SHOWRUNNER™ Topology"]]
156 -)))
157 157  
158 -(% class="box" %)
159 -(((
145 +
160 160  **SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**
147 +
161 161  [[image:ZumFhSr\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]]
162 -)))
163 163  
164 -(% class="box" %)
165 -(((
150 +
166 166  **ZUM-FLOOR-HUB Only**
167 -[[image:ZumFh\@2x.png||alt="Zum Floor Hub Topology"]]
168 -)))
169 169  
170 -(% class="box" %)
171 -(((
153 +[[image:ZumApp\@2x.png||alt="Zum App Topology"]]
154 +
155 +
172 172  **Zūm iOS/Android Setup App**
157 +
173 173  [[image:ZumApp\@2x.png||alt="Zum App Topology"]]
174 -)))