1 -Zum wired can be deployed in App (Zum) Mode or CNET Mode.  App mode will perform lighting control logic within the Zum JBOX hardware while CNET mode pushes all logic back to the Control System.  ShowRunnerCLC™ supports both modes and can be used to enhance app mode or allow complete control over the hardware to perform functionality.  All hardware does not need to be in app mode on a project.  You can mix and match as needed.
1 +Zum wired can be deployed in App (Zum) Mode or CNET Mode.  App mode will perform lighting control logic within the Zum JBOX hardware while CNET mode pushes all logic back to the Control System.  ShowRunnerCLC™ supports both modes and can be used to enhance app mode or allow complete control over the hardware to perform functionality.  All hardware does not need to be in app mode on a project.  You can mix and match as needed.  This is not an exhaustive list but serves as a guide for when Zum is required to be in CNET mode to achieve the desired functionality.
2 2  
3 3  (% class="box warningmessage" %)
4 4  (((
... ... @@ -26,7 +26,7 @@
26 26  |Crestron non-Zum Hardware Integration|Y^^1^^|Y|N
27 27  |Non-Crestron Hardware Integration|Y^^1^^|Y|N
28 28  |Multiple ZUMNET Masters in a Single Room|Y^^1^^|Y|N
29 -|Logic for More than One Room|Not Recommended, Requires Groups within App Mode|Y|Requires Groups
29 +|More than One Room per ZUMNET|Not Recommended, Requires Groups within App Mode|Y|Requires Groups
30 30  |Scheduling / Time Clock|Y^^1^^|Y|ZUMLINK-[DIN/JBOX]-IO per room or HUB4
31 31  |Dynamic White|Y^^1^^|Y|N
32 32  |(% colspan="4" %)**DALI**
... ... @@ -45,7 +45,7 @@
45 45  ShowRunnerCLC™: Unlimited
46 46  Local logic: 16 + Off
47 47  )))|Unlimited|16 + Off
48 -|Per Scene Fade Times|Y^^1^^|Y|Partial
48 +|Per Scene Fade Times|Y^^1,2,4^^|Y|Partial^^4^^
49 49  |(% colspan="4" %)**Loads**
50 50  |Min/Max Trim|Y^^2^^|(((
51 51  Y
... ... @@ -59,7 +59,7 @@
59 59  |RGB|Y^^1^^|Y|N
60 60  |(% colspan="4" %)**Occupancy Logic**
61 61  |Occupancy Modes|Y^^2^^|Y|Y
62 -|Grace Timeout|Y|Y|N
62 +|Grace Timeout|Y^^1^^|Y|N
63 63  |Extended Timeout|Y^^1^^|Y|N
64 64  |2 Stage Vacancy|Y^^1^^|Y|N
65 65  |(% colspan="4" %)**Keypads**
... ... @@ -67,51 +67,12 @@
67 67  |Custom Keypad Programming|Y^^2^^|Y|N
68 68  |(% colspan="2" rowspan="1" %)**Room Logic**| |
69 69  |After Hours / Auto Timeout|Y^^1^^|Y|N
70 +|Plug Load (Auto/On/Off)|Y^^1^^|Y|Internal behavior only
70 70  |Recall Last Level|Y^^1^^|Y|N
71 -| | | |
72 -| | | |
73 -| | | |
74 -| | | |
75 -| | | |
76 -| | | |
77 -| | | |
78 -| | | |
79 -| | | |
80 -| | | |
81 -| | | |
82 -| | | |
83 -| | | |
84 -| | | |
85 -| | | |
86 -| | | |
87 -| | | |
88 -| | | |
89 -| | | |
90 -| | | |
91 -| | | |
92 -| | | |
93 -| | | |
94 -| | | |
95 -| | | |
96 -| | | |
97 -| | | |
98 -| | | |
99 -| | | |
100 -| | | |
101 -| | | |
102 -| | | |
103 -| | | |
104 -| | | |
105 -| | | |
106 -| | | |
107 -| | | |
108 -| | | |
109 -| | | |
110 110  
111 -
112 112  ==== Notes ====
113 113  
114 114  1 - [App Mode Only] Logic must be handled by ShowRunnerCLC™.  An active connection to the control system/ShowRunnerCLC™ is required.
115 -2 - [App Mode Only] Some logic may be handled by ShowRunnerCLC™ depending on active setting.  An active connection to the control system/ShowRunnerCLC™ may be required.
76 +2 - [App Mode Only] Some logic may be handled by ShowRunnerCLC™ depending on active setting.  An active connection to the control system/ShowRunnerCLC™ will be required if handled by ShowRunnerCLC™.
116 116  3 - [App Mode Only] Keypad Required
117 117  4 - [App Mode Only] 3 settings, On/Off and All Scenes Only, configured per load, max of 30 seconds