Changes for page Crestron Zūm Wired
Last modified by Mark Kohlmann on 2026/04/07 18:02
From version 20.1
edited by Mark Kohlmann
on 2026/03/10 14:28
on 2026/03/10 14:28
Change comment:
There is no comment for this version
To version 18.1
edited by Mark Kohlmann
on 2022/03/09 21:23
on 2022/03/09 21:23
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - true1 +false - Content
-
... ... @@ -1,56 +1,56 @@ 1 -Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. S howRunnerCLC™ provides a number of integrations options that allow the designer to optimize the solution design.1 + Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 -~*~*~* Specifications are preliminary, the Zūm wired ZUM-HUB 4has not been released ~*~**3 +~*~*~* Specifications are preliminary, the Zūm wired ZUM-FLOOR-HUB has not been released ~*~** 4 4 5 5 ==== Integration Options ==== 6 6 7 -* **S howRunnerCLC™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-HUB4in the system design.8 -* **S howRunnerCLC™ + ZUM-HUB4** - Provides limited scene recall and room status for Zūm rooms paired with the HUB4. ShowRunnerCLC™ can export its own areas to the HUB4.7 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design. 8 +* **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 9 9 10 10 ==== Feature Matrix ==== 11 11 12 -|=Feature|=S howRunnerCLC™ Total Control|=ShowRunnerCLC™ (External Room Export) + ZUM-HUB44(Mirror Driver)|=ZUM-HUB44Only|=Zūm iOS/Android Setup App*12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="5" %)**Hardware Requirements** 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A 16 -|Requires Physical Presence in Room to Change Scenes|N| N|N|Y17 -|Maximum Rooms| 1000|1000|1000|N/A16 +|Requires Physical Presence in Room to Change Scenes|N|TBD|TBD|Y 17 +|Maximum Rooms|TBD|1000|1000|N/A 18 18 |(% colspan="5" %)**User Interfaces** 19 19 |Web Browser|((( 20 20 Crestron SmartGraphics XPanel 21 21 HTML5 UI 22 -)))|S howRunnerCLC™ - Crestron SmartGraphics XPanel/HTML5 UI23 -ZUM-HUB 4- HTML5 UI|HTML5 UI|N22 +)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI 23 +ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 24 |iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N 26 26 |(% colspan="5" %)**Features** 27 27 |Scene Recall|Y|Y|Y|Y 28 -|Override Fade Time for Scene Recall|Y| N|N|N29 -|Scene Save|Y| Y, via HUB4|Y|Y30 -|Load Control|Y| Y, via HUB4|Y|Y31 -|Demand Response|Y|Y, separate triggers for S howRunnerCLC™ and ZUM-HUB4required|Y|N32 -|Enable/Disable Occupancy|Y|Y, from H UB4|Y|Y33 -|Override Occupancy Logic|Y| Y, via ShowRunner|N|N28 +|Override Fade Time for Scene Recall|Y|TBD|TBD|TBD 29 +|Scene Save|Y|TBD|TBD|Y 30 +|Load Control|Y|TBD|TBD|Y 31 +|Demand Response|Y|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 32 +|Enable/Disable Occupancy|Y|Y, from Floor Hub|Y|Y 33 +|Override Occupancy Logic|Y|TBD|TBD|N 34 34 |Override|Y|Scene Recall only via ShowRunner|TBD|N/A 35 35 |Plug Load On/Off|Y|Y|Y|By Hardware 36 36 |Integration with Non-Zūm Crestron Hardware|Y|N|N|N 37 37 |Custom Zūm Keypad Programming|Y|TBD|TBD|Y, within the limits of the hardware 38 -|New Feature Release Cycle|Aggressive|S howRunnerCLC™: Aggressive39 -H UB4: 6-12 months|6-12 months|6-12 months38 +|New Feature Release Cycle|Aggressive|SHOWRUNNER™: Aggressive 39 +Floor Hub: 6-12 months|6-12 months|6-12 months 40 40 |Room Organization|((( 41 41 Organize According to Defined Nodes, multiple levels 42 42 Categorization to Filter by Tag 43 -)))|S howRunnerCLC™: See ShowRunnerCLC™ Total Control44 -H UB4: Category/Room|Category/Room|(((43 +)))|SHOWRUNNER™: See SHOWRUNNER™ Total Control 44 +Floor Hub: Category/Room|Category/Room|((( 45 45 N/A 46 46 ))) 47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|S howRunnerCLC™: Automatic discovery (Pending)48 -H UB4: Map Mirrored Rooms to ShowRunnerCLC™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|SHOWRUNNER™: Automatic discovery (Pending) 48 +Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 49 49 |Network Topology|((( 50 50 * Flat 51 51 * Single Handoff to LAN w/ Control Subnet 52 52 (Requires CP4N/AV4/PRO4) 53 -)))|Single Handoff to LAN w/ Control Subnet. ShowRunner CLC™can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A53 +)))|Single Handoff to LAN w/ Control Subnet. ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 54 54 |Network Addressing|((( 55 55 * Manual 56 56 * Customer (DHCP or Manual) ... ... @@ -57,31 +57,31 @@ 57 57 * DHCP: Control Subnet (Requires CP4N/AV4/PRO4) 58 58 )))|Control Subnet|Control Subnet|N/A 59 59 |Firmware Updates|PUF Tool 60 -Automatic Support on Roadmap|S howRunnerCLC™: PUF Tool61 -H UB4: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A62 -|Floorplans|Y|S howRunnerCLC™: Y63 -H UB4: N|N|N/A60 +Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool 61 +Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 +|Floorplans|Y|SHOWRUNNER™: Y 63 +Floor Hub: N|N|N/A 64 64 |(% colspan="5" %)**Calendar/Scheduling** 65 65 |Logic Type|Event Driven 66 -Profile Support (Under Development)|S howRunnerCLC™: Event Driven67 -H UB4: Pattern assigned to Category|Pattern assigned to Category|N/A66 +Profile Support (Under Development)|SHOWRUNNER™: Event Driven 67 +Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 68 68 |Astronomical Clock|Y|Y, Per Category|Y, Per Category|N/A 69 -|Holidays|Pattern|S howRunnerCLC™: Pattern70 -H UB4: Hard Coded|Hard Coded|N/A71 -|Custom Patterns|Y, Advanced Scheduler License|S howRunnerCLC™: Y, Advanced Scheduler License72 -H UB4: N|N|N/A69 +|Holidays|Pattern|SHOWRUNNER™: Pattern 70 +Floor Hub: Hard Coded|Hard Coded|N/A 71 +|Custom Patterns|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 72 +Floor Hub: N|N|N/A 73 73 |(% colspan="5" %)**Integrations** 74 -|A/V Integration: API|Y|S howRunnerCLC™: Y75 -H UB4: Limited|Limited|N/A76 -|A/V Integration: Crestron EISC|Y|S howRunnerCLC™: Y77 -H UB4: N|N|N/A74 +|A/V Integration: API|Y|SHOWRUNNER™: Y 75 +Floor Hub: Limited|Limited|N/A 76 +|A/V Integration: Crestron EISC|Y|SHOWRUNNER™: Y 77 +Floor Hub: N|N|N/A 78 78 |A/V Integration: RS-232|Y|((( 79 -S howRunnerCLC™: Y80 -H UB4: TBD79 +SHOWRUNNER™: Y 80 +Floor Hub: TBD 81 81 )))|TBD|N/A 82 82 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 83 -S howRunnerCLC™: ShowRunnerCLC™ and Crestron Licenses Needed84 -H UB4: Y83 +SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 84 +Floor Hub: Y 85 85 )))|Y|N/A 86 86 |BACNET Features|((( 87 87 Per Area Status: ... ... @@ -98,8 +98,8 @@ 98 98 99 99 ~* More Features added upon request 100 100 )))|((( 101 -S howRunnerCLC™: See list for ShowRunnerCLC™ Total Control102 -H UB4: See list for ZUM-HUB4101 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 102 +Floor Hub: See list for ZUM-FLOOR-HUB 103 103 )))|((( 104 104 Per Room Status: 105 105 Online ... ... @@ -116,36 +116,35 @@ 116 116 )))|N/A 117 117 |BACNET Settings Scope 118 118 (What Points are Exposed)|Per Area|((( 119 -S howRunnerCLC™: Per Area120 -H UB4: Global119 +SHOWRUNNER™: Per Area 120 +Floor Hub: Global 121 121 )))|Global|N/A 122 -|BACNET Points Supported|Depends on Crestron License and Hardware 123 -See [[BACnet Integration>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.ShowRunner BACNET Points.WebHome]]|ShowRunnerCLC™: Depends on Crestron License and Hardware 124 -HUB4: 9000|1000|N/A 122 +|BACNET Points Supported|Depends on Crestron License and Hardware|SHOWRUNNER™: Depends on Crestron License and Hardware 123 +Floor Hub: 1000|1000|N/A 125 125 |Crestron Fusion|Y|((( 126 -S howRunnerCLC™: Y127 -H UB4: N125 +SHOWRUNNER™: Y 126 +Floor Hub: N 128 128 )))|N|N/A 129 -|Export to Zūm H UB4|Y, Licensed|ShowRunnerCLC™: Y, Licensed|N/A|N/A130 -|GLPAC|Y|S howRunnerCLC™: Y131 -H UB4: Via ShowRunnerCLC™|N|N/A128 +|Export to Zūm Floor Hub|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A 129 +|GLPAC|Y|SHOWRUNNER™: Y 130 +Floor Hub: Via SHOWRUNNER™|N|N/A 132 132 |System to System Link|Y|((( 133 -S howRunnerCLC™: Y134 -H UB4: N132 +SHOWRUNNER™: Y 133 +Floor Hub: N 135 135 )))|N|N/A 136 136 |Minimum ZUM-NET Firmware|((( 137 137 CNET Mode: ZUM-WIRED 1.02.10 puf 138 138 ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 139 139 )))|((( 140 -S howRunnerCLC™: TBD141 -H UB4: TBD139 +SHOWRUNNER™: TBD 140 +Floor Hub: TBD 142 142 )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 143 143 |Minimum SHOWRUNNER™ Version|((( 144 144 CNET Mode: 3.016 145 145 ZUM Mode: TBD 146 146 )))|N/A|N/A|N/A 147 -|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as H UB4|MASTER|MASTER or SLAVE148 -|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as H UB4|ZUM|ZUM146 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE 147 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM 149 149 150 150 {{id name="caveats"/}} 151 151 ... ... @@ -159,8 +159,8 @@ 159 159 160 160 ==== FAQ: ==== 161 161 162 -* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-HUB 4) and use ShowRunner™ Total Control?163 -//Use a CP4N in lieu of the ZUM-HUB 4. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//161 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 162 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 164 164 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 165 165 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 166 166 ... ... @@ -168,11 +168,11 @@ 168 168 169 169 ==== Topologies ==== 170 170 171 -**S howRunnerCLC™ Total Control (Control Subnet or Flat)**170 +**SHOWRUNNER™ Total Control (Control Subnet or Flat)** 172 172 [[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]] 173 173 174 -**S howRunnerCLC™ (External Room Export) + ZUM-HUB4(Mirror Driver)**175 -[[image:ZumWired_SRtoFH\@2x.png||alt="Zum H UB4+ SHOWRUNNER™ Topology"]]173 +**SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)** 174 +[[image:ZumWired_SRtoFH\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]] 176 176 177 -**ZUM-HUB 4Only**178 -[[image:ZumWired_FH\@2x.png||alt="Zum H UB4Only"]]176 +**ZUM-FLOOR-HUB Only** 177 +[[image:ZumWired_FH\@2x.png||alt="Zum Floor Hub Only"]]