Changes for page Crestron Zūm Wired
Last modified by Scott Kohlmann on 2023/04/20 22:22
From version 2.1
edited by Mark Kohlmann
on 2021/05/05 22:38
on 2021/05/05 22:38
Change comment:
There is no comment for this version
To version 11.1
edited by Mark Kohlmann
on 2021/05/06 15:18
on 2021/05/06 15:18
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,6 +14,7 @@ 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A 16 16 |Requires Physical Presence in Room to Change Scenes|N|TBD|TBD|Y 17 +|Maximum Rooms|TBD|1000|1000|N/A 17 17 |(% colspan="5" %)**User Interfaces** 18 18 |Web Browser|((( 19 19 Crestron SmartGraphics XPanel ... ... @@ -48,16 +48,18 @@ 48 48 |Network Topology|((( 49 49 * Flat 50 50 * Single Handoff to LAN w/ Control Subnet 51 -(Requires CP 3N/CP4N/AV3/AV4/PRO3/PRO4)52 +(Requires CP4N/AV4/PRO4) 52 52 )))|Single Handoff to LAN w/ Control Subnet. ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 53 53 |Network Addressing|((( 54 54 * Manual 55 -* Customer 56 -* Control Subnet (Requires CP 3N/CP4N/AV3/AV4/PRO3/PRO4)56 +* Customer (DHCP or Manual) 57 +* DHCP: Control Subnet (Requires CP4N/AV4/PRO4) 57 57 )))|Control Subnet|Control Subnet|N/A 58 58 |Firmware Updates|PUF Tool 59 59 Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool 60 60 Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 +|Floorplans|Y|SHOWRUNNER™: Y 63 +Floor Hub: N|N|N/A 61 61 |(% colspan="5" %)**Calendar/Scheduling** 62 62 |Logic Type|Event Driven 63 63 Profile Support (Under Development)|SHOWRUNNER™: Event Driven ... ... @@ -139,14 +139,22 @@ 139 139 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 140 140 * Additional caveats TBD 141 141 145 +==== FAQ: ==== 146 + 147 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 148 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required.// 149 +* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 150 +//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 151 + 152 +==== ==== 153 + 142 142 ==== Topologies ==== 143 143 144 -**SHOWRUNNER™ Total Control** 145 -[[image:Zum Sr\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology"]]156 +**SHOWRUNNER™ Total Control (Control Subnet or Flat)** 157 +[[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]] 146 146 147 147 **SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)** 148 -[[image:Zum FhSr\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]]160 +[[image:ZumWired_SRtoFH\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]] 149 149 150 150 **ZUM-FLOOR-HUB Only** 151 - 152 - 163 +[[image:ZumWired_FH\@2x.png||alt="Zum Floor Hub Only"]]
- ZumWired_FH@2x.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.3 KB - Content
- ZumWired_FH@4x.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +182.8 KB - Content
- ZumWired_SR-CS@2x.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- ZumWired_SR-Flat@2x.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content
- ZumWired_SRtoFH@2x.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.5 KB - Content