Summary

Details

Page properties
Content
... ... @@ -14,6 +14,7 @@
14 14  |Requires ZUMNET JBox|Y|Y|Y|N
15 15  |Requires 3 or 4-Series Control System|Y|Y|N|N/A
16 16  |Requires Physical Presence in Room to Change Scenes|N|TBD|TBD|Y
17 +|Maximum Rooms|TBD|1000|1000|N/A
17 17  |(% colspan="5" %)**User Interfaces**
18 18  |Web Browser|(((
19 19  Crestron SmartGraphics XPanel
... ... @@ -48,16 +48,18 @@
48 48  |Network Topology|(((
49 49  * Flat
50 50  * Single Handoff to LAN w/ Control Subnet
51 -(Requires  CP3N/CP4N/AV3/AV4/PRO3/PRO4)
52 +(Requires  CP4N/AV4/PRO4)
52 52  )))|Single Handoff to LAN w/ Control Subnet.  ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A
53 53  |Network Addressing|(((
54 54  * Manual
55 -* Customer
56 -* Control Subnet (Requires CP3N/CP4N/AV3/AV4/PRO3/PRO4)
56 +* Customer (DHCP or Manual)
57 +* DHCP: Control Subnet (Requires CP4N/AV4/PRO4)
57 57  )))|Control Subnet|Control Subnet|N/A
58 58  |Firmware Updates|PUF Tool
59 59  Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool
60 60  Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A
62 +|Floorplans|Y|SHOWRUNNER™: Y
63 +Floor Hub: N|N|N/A
61 61  |(% colspan="5" %)**Calendar/Scheduling**
62 62  |Logic Type|Event Driven
63 63  Profile Support (Under Development)|SHOWRUNNER™: Event Driven
... ... @@ -139,14 +139,22 @@
139 139  * Consult Chief Integrations to verify sequence of operations if there are any concerns.
140 140  * Additional caveats TBD
141 141  
145 +==== FAQ: ====
146 +
147 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control?
148 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.//
149 +* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
150 +//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
151 +
152 +==== ====
153 +
142 142  ==== Topologies ====
143 143  
144 -**SHOWRUNNER™ Total Control**
145 -[[image:ZumSr\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology"]]
156 +**SHOWRUNNER™ Total Control (Control Subnet or Flat)**
157 +[[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]]
146 146  
147 147  **SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**
148 -[[image:ZumFhSr\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]]
160 +[[image:ZumWired_SRtoFH\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]]
149 149  
150 150  **ZUM-FLOOR-HUB Only**
151 -
152 -
163 +[[image:ZumWired_FH\@2x.png||alt="Zum Floor Hub Only"]]
ZumWired_FH@2x.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +48.3 KB
Content
ZumWired_FH@4x.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +182.8 KB
Content
ZumWired_SR-CS@2x.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
ZumWired_SR-Flat@2x.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +64.6 KB
Content
ZumWired_SRtoFH@2x.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +92.5 KB