Changes for page Crestron Zūm Wired
Last modified by Scott Kohlmann on 2023/04/20 22:22
From version 18.2
edited by Alexander Mott
on 2023/03/24 15:29
on 2023/03/24 15:29
Change comment:
There is no comment for this version
To version 13.1
edited by Mark Kohlmann
on 2021/10/05 22:11
on 2021/10/05 22:11
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Design Guide.Hardware Design Guide.WebHome 1 +SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - true1 +false - Content
-
... ... @@ -1,4 +1,4 @@ 1 -Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 1 + Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 3 ~*~*~* Specifications are preliminary, the Zūm wired ZUM-FLOOR-HUB has not been released ~*~** 4 4 ... ... @@ -21,7 +21,7 @@ 21 21 HTML5 UI 22 22 )))|SHOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI 23 23 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 -|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*24 +|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N 26 26 |(% colspan="5" %)**Features** 27 27 |Scene Recall|Y|Y|Y|Y ... ... @@ -133,14 +133,11 @@ 133 133 Floor Hub: N 134 134 )))|N|N/A 135 135 |Minimum ZUM-NET Firmware|((( 136 -CNET Mode: ZUM-WIRED 1.0 2.10 puf136 +CNET Mode: ZUM-WIRED 1.00.09 puf 137 137 ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 -)))|((( 139 -SHOWRUNNER™: TBD 140 -Floor Hub: TBD 141 -)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 138 +)))|N/A|See Crestron|See Crestron 142 142 |Minimum SHOWRUNNER™ Version|((( 143 -CNET Mode: 3.0 16140 +CNET Mode: 3.003 144 144 ZUM Mode: TBD 145 145 )))|N/A|N/A|N/A 146 146 |ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE ... ... @@ -152,14 +152,14 @@ 152 152 153 153 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 154 154 * Additional caveats: 155 -** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.156 -** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.157 -** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware.152 +** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 153 +** Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 154 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 158 158 159 159 ==== FAQ: ==== 160 160 161 161 * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 162 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//159 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.// 163 163 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 164 164 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 165 165