Changes for page Crestron Zūm Wired
Last modified by Mark Kohlmann on 2026/04/07 18:02
From version 18.1
edited by Mark Kohlmann
on 2022/03/09 21:23
on 2022/03/09 21:23
Change comment:
There is no comment for this version
To version 21.1
edited by Mark Kohlmann
on 2026/03/10 16:50
on 2026/03/10 16:50
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -1,56 +1,56 @@ 1 - Crestron Zūm Wired is a locally integrated lighting control system with various global control options.Zūm rooms are self-contained control units with primary logic occurring at the room level.Central control systems offer scheduling and management. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.1 +Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. ShowRunnerCLC™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 -~*~*~* Specifications are preliminary, the Zūm wired ZUM- FLOOR-HUB has not been released ~*~**3 +~*~*~* Specifications are preliminary, the Zūm wired ZUM-HUB4 has not been released ~*~** 4 4 5 5 ==== Integration Options ==== 6 6 7 -* **S HOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.8 -* **S HOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with theFloorHub. SHOWRUNNER™ can export its own areas to theFloorHub.7 +* **ShowRunnerCLC™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-HUB4 in the system design. 8 +* **ShowRunnerCLC™ + ZUM-HUB4** - Provides limited scene recall and room status for Zūm rooms paired with the HUB4. ShowRunnerCLC™ can export its own areas to the HUB4. 9 9 10 10 ==== Feature Matrix ==== 11 11 12 -|=Feature|=S HOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App*12 +|=Feature|=ShowRunnerCLC™ Total Control|=ShowRunnerCLC™ (External Room Export) + ZUM-HUB44 (Mirror Driver)|=ZUM-HUB44 Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="5" %)**Hardware Requirements** 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A 16 -|Requires Physical Presence in Room to Change Scenes|N| TBD|TBD|Y17 -|Maximum Rooms| TBD|1000|1000|N/A16 +|Requires Physical Presence in Room to Change Scenes|N|N|N|Y 17 +|Maximum Rooms|1000|1000|1000|N/A 18 18 |(% colspan="5" %)**User Interfaces** 19 19 |Web Browser|((( 20 20 Crestron SmartGraphics XPanel 21 21 HTML5 UI 22 -)))|S HOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI23 -ZUM- FLOOR-HUB - HTML5 UI|HTML5 UI|N22 +)))|ShowRunnerCLC™ - Crestron SmartGraphics XPanel/HTML5 UI 23 +ZUM-HUB4 - HTML5 UI|HTML5 UI|N 24 24 |iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N 26 26 |(% colspan="5" %)**Features** 27 27 |Scene Recall|Y|Y|Y|Y 28 -|Override Fade Time for Scene Recall|Y| TBD|TBD|TBD29 -|Scene Save|Y| TBD|TBD|Y30 -|Load Control|Y| TBD|TBD|Y31 -|Demand Response|Y|Y, separate triggers for S HOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N32 -|Enable/Disable Occupancy|Y|Y, from FloorHub|Y|Y33 -|Override Occupancy Logic|Y| TBD|TBD|N28 +|Override Fade Time for Scene Recall|Y|N|N|N 29 +|Scene Save|Y|Y, via HUB4|Y|Y 30 +|Load Control|Y|Y, via HUB4|Y|Y 31 +|Demand Response|Y|Y, separate triggers for ShowRunnerCLC™ and ZUM-HUB4 required|Y|N 32 +|Enable/Disable Occupancy|Y|Y, from HUB4|Y|Y 33 +|Override Occupancy Logic|Y|Y, via ShowRunner|N|N 34 34 |Override|Y|Scene Recall only via ShowRunner|TBD|N/A 35 35 |Plug Load On/Off|Y|Y|Y|By Hardware 36 36 |Integration with Non-Zūm Crestron Hardware|Y|N|N|N 37 37 |Custom Zūm Keypad Programming|Y|TBD|TBD|Y, within the limits of the hardware 38 -|New Feature Release Cycle|Aggressive|S HOWRUNNER™: Aggressive39 - FloorHub: 6-12 months|6-12 months|6-12 months38 +|New Feature Release Cycle|Aggressive|ShowRunnerCLC™: Aggressive 39 +HUB4: 6-12 months|6-12 months|6-12 months 40 40 |Room Organization|((( 41 41 Organize According to Defined Nodes, multiple levels 42 42 Categorization to Filter by Tag 43 -)))|S HOWRUNNER™: See SHOWRUNNER™ Total Control44 - FloorHub: Category/Room|Category/Room|(((43 +)))|ShowRunnerCLC™: See ShowRunnerCLC™ Total Control 44 +HUB4: Category/Room|Category/Room|((( 45 45 N/A 46 46 ))) 47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|S HOWRUNNER™: Automatic discovery (Pending)48 - FloorHub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|ShowRunnerCLC™: Automatic discovery (Pending) 48 +HUB4: Map Mirrored Rooms to ShowRunnerCLC™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 49 49 |Network Topology|((( 50 50 * Flat 51 51 * Single Handoff to LAN w/ Control Subnet 52 52 (Requires CP4N/AV4/PRO4) 53 -)))|Single Handoff to LAN w/ Control Subnet. ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 53 +)))|Single Handoff to LAN w/ Control Subnet. ShowRunnerCLC™ can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 54 54 |Network Addressing|((( 55 55 * Manual 56 56 * Customer (DHCP or Manual) ... ... @@ -57,31 +57,31 @@ 57 57 * DHCP: Control Subnet (Requires CP4N/AV4/PRO4) 58 58 )))|Control Subnet|Control Subnet|N/A 59 59 |Firmware Updates|PUF Tool 60 -Automatic Support on Roadmap|S HOWRUNNER™: PUF Tool61 - FloorHub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A62 -|Floorplans|Y|S HOWRUNNER™: Y63 - FloorHub: N|N|N/A60 +Automatic Support on Roadmap|ShowRunnerCLC™: PUF Tool 61 +HUB4: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 +|Floorplans|Y|ShowRunnerCLC™: Y 63 +HUB4: N|N|N/A 64 64 |(% colspan="5" %)**Calendar/Scheduling** 65 65 |Logic Type|Event Driven 66 -Profile Support (Under Development)|S HOWRUNNER™: Event Driven67 - FloorHub: Pattern assigned to Category|Pattern assigned to Category|N/A66 +Profile Support (Under Development)|ShowRunnerCLC™: Event Driven 67 +HUB4: Pattern assigned to Category|Pattern assigned to Category|N/A 68 68 |Astronomical Clock|Y|Y, Per Category|Y, Per Category|N/A 69 -|Holidays|Pattern|S HOWRUNNER™: Pattern70 - FloorHub: Hard Coded|Hard Coded|N/A71 -|Custom Patterns|Y, Advanced Scheduler License|S HOWRUNNER™: Y, Advanced Scheduler License72 - FloorHub: N|N|N/A69 +|Holidays|Pattern|ShowRunnerCLC™: Pattern 70 +HUB4: Hard Coded|Hard Coded|N/A 71 +|Custom Patterns|Y, Advanced Scheduler License|ShowRunnerCLC™: Y, Advanced Scheduler License 72 +HUB4: N|N|N/A 73 73 |(% colspan="5" %)**Integrations** 74 -|A/V Integration: API|Y|S HOWRUNNER™: Y75 - FloorHub: Limited|Limited|N/A76 -|A/V Integration: Crestron EISC|Y|S HOWRUNNER™: Y77 - FloorHub: N|N|N/A74 +|A/V Integration: API|Y|ShowRunnerCLC™: Y 75 +HUB4: Limited|Limited|N/A 76 +|A/V Integration: Crestron EISC|Y|ShowRunnerCLC™: Y 77 +HUB4: N|N|N/A 78 78 |A/V Integration: RS-232|Y|((( 79 -S HOWRUNNER™: Y80 - FloorHub: TBD79 +ShowRunnerCLC™: Y 80 +HUB4: TBD 81 81 )))|TBD|N/A 82 82 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 83 -S HOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed84 - FloorHub: Y83 +ShowRunnerCLC™: ShowRunnerCLC™ and Crestron Licenses Needed 84 +HUB4: Y 85 85 )))|Y|N/A 86 86 |BACNET Features|((( 87 87 Per Area Status: ... ... @@ -98,8 +98,8 @@ 98 98 99 99 ~* More Features added upon request 100 100 )))|((( 101 -S HOWRUNNER™: See list for SHOWRUNNER™ Total Control102 - FloorHub: See list for ZUM-FLOOR-HUB101 +ShowRunnerCLC™: See list for ShowRunnerCLC™ Total Control 102 +HUB4: See list for ZUM-HUB4 103 103 )))|((( 104 104 Per Room Status: 105 105 Online ... ... @@ -116,35 +116,36 @@ 116 116 )))|N/A 117 117 |BACNET Settings Scope 118 118 (What Points are Exposed)|Per Area|((( 119 -S HOWRUNNER™: Per Area120 - FloorHub: Global119 +ShowRunnerCLC™: Per Area 120 +HUB4: Global 121 121 )))|Global|N/A 122 -|BACNET Points Supported|Depends on Crestron License and Hardware|SHOWRUNNER™: Depends on Crestron License and Hardware 123 -Floor Hub: 1000|1000|N/A 122 +|BACNET Points Supported|Depends on Crestron License and Hardware 123 +See [[BACnet Integration>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.ShowRunner BACNET Points.WebHome]]|ShowRunnerCLC™: Depends on Crestron License and Hardware 124 +HUB4: 9000|1000|N/A 124 124 |Crestron Fusion|Y|((( 125 -S HOWRUNNER™: Y126 - FloorHub: N126 +ShowRunnerCLC™: Y 127 +HUB4: N 127 127 )))|N|N/A 128 -|Export to Zūm FloorHub|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A129 -|GLPAC|Y|S HOWRUNNER™: Y130 - FloorHub: Via SHOWRUNNER™|N|N/A129 +|Export to Zūm HUB4|Y, Licensed|ShowRunnerCLC™: Y, Licensed|N/A|N/A 130 +|GLPAC|Y|ShowRunnerCLC™: Y 131 +HUB4: Via ShowRunnerCLC™|N|N/A 131 131 |System to System Link|Y|((( 132 -S HOWRUNNER™: Y133 - FloorHub: N133 +ShowRunnerCLC™: Y 134 +HUB4: N 134 134 )))|N|N/A 135 135 |Minimum ZUM-NET Firmware|((( 136 136 CNET Mode: ZUM-WIRED 1.02.10 puf 137 137 ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 138 )))|((( 139 -S HOWRUNNER™: TBD140 - FloorHub: TBD140 +ShowRunnerCLC™: TBD 141 +HUB4: TBD 141 141 )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 142 142 |Minimum SHOWRUNNER™ Version|((( 143 143 CNET Mode: 3.016 144 144 ZUM Mode: TBD 145 145 )))|N/A|N/A|N/A 146 -|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as FloorHub|MASTER|MASTER or SLAVE147 -|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as FloorHub|ZUM|ZUM147 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as HUB4|MASTER|MASTER or SLAVE 148 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as HUB4|ZUM|ZUM 148 148 149 149 {{id name="caveats"/}} 150 150 ... ... @@ -158,8 +158,8 @@ 158 158 159 159 ==== FAQ: ==== 160 160 161 -* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM- FLOOR-HUB) and use ShowRunner™ Total Control?162 -//Use a CP4N in lieu of the ZUM- FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//162 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-HUB4) and use ShowRunner™ Total Control? 163 +//Use a CP4N in lieu of the ZUM-HUB4. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 163 163 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 164 164 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 165 165 ... ... @@ -167,11 +167,11 @@ 167 167 168 168 ==== Topologies ==== 169 169 170 -**S HOWRUNNER™ Total Control (Control Subnet or Flat)**171 +**ShowRunnerCLC™ Total Control (Control Subnet or Flat)** 171 171 [[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]] 172 172 173 -**S HOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**174 -[[image:ZumWired_SRtoFH\@2x.png||alt="Zum FloorHub+ SHOWRUNNER™ Topology"]]174 +**ShowRunnerCLC™ (External Room Export) + ZUM-HUB4 (Mirror Driver)** 175 +[[image:ZumWired_SRtoFH\@2x.png||alt="Zum HUB4 + SHOWRUNNER™ Topology"]] 175 175 176 -**ZUM- FLOOR-HUB Only**177 -[[image:ZumWired_FH\@2x.png||alt="Zum FloorHubOnly"]]177 +**ZUM-HUB4 Only** 178 +[[image:ZumWired_FH\@2x.png||alt="Zum HUB4 Only"]]