Changes for page Crestron Zūm Wired
Last modified by Scott Kohlmann on 2023/04/20 22:22
From version 17.2
edited by Mark Kohlmann
on 2021/12/08 00:15
on 2021/12/08 00:15
Change comment:
Update document after refactoring.
To version 18.1
edited by Mark Kohlmann
on 2022/03/09 21:23
on 2022/03/09 21:23
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -133,7 +133,7 @@ 133 133 Floor Hub: N 134 134 )))|N|N/A 135 135 |Minimum ZUM-NET Firmware|((( 136 -CNET Mode: ZUM-WIRED 1.0 0.09puf136 +CNET Mode: ZUM-WIRED 1.02.10 puf 137 137 ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 138 )))|((( 139 139 SHOWRUNNER™: TBD ... ... @@ -140,7 +140,7 @@ 140 140 Floor Hub: TBD 141 141 )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 142 142 |Minimum SHOWRUNNER™ Version|((( 143 -CNET Mode: 3.0 03143 +CNET Mode: 3.016 144 144 ZUM Mode: TBD 145 145 )))|N/A|N/A|N/A 146 146 |ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE ... ... @@ -152,8 +152,8 @@ 152 152 153 153 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 154 154 * Additional caveats: 155 -** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 156 -** Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 155 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 156 +** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 157 157 ** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 158 158 159 159 ==== FAQ: ==== ... ... @@ -163,7 +163,7 @@ 163 163 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 164 164 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 165 165 166 -==== ==== 166 +==== ==== 167 167 168 168 ==== Topologies ==== 169 169