Changes for page Crestron Zūm Wired

Last modified by Scott Kohlmann on 2023/04/20 22:22

From version 17.2
edited by Mark Kohlmann
on 2021/12/08 00:15
Change comment: Update document after refactoring.
To version 18.1
edited by Mark Kohlmann
on 2022/03/09 21:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -133,7 +133,7 @@
133 133  Floor Hub: N
134 134  )))|N|N/A
135 135  |Minimum ZUM-NET Firmware|(((
136 -CNET Mode: ZUM-WIRED 1.00.09 puf
136 +CNET Mode: ZUM-WIRED 1.02.10 puf
137 137  ZUM Mode: ZUM-WIRED  1.xx.xxx puf (Pending)
138 138  )))|(((
139 139  SHOWRUNNER™: TBD
... ... @@ -140,7 +140,7 @@
140 140  Floor Hub: TBD
141 141  )))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
142 142  |Minimum SHOWRUNNER™ Version|(((
143 -CNET Mode: 3.003
143 +CNET Mode: 3.016
144 144  ZUM Mode: TBD
145 145  )))|N/A|N/A|N/A
146 146  |ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE
... ... @@ -152,8 +152,8 @@
152 152  
153 153  * Consult Chief Integrations to verify sequence of operations if there are any concerns.
154 154  * Additional caveats:
155 -** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.
156 -** Raw Occupancy reporting does not work.  A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner.  ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.
155 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
156 +** --Raw Occupancy reporting does not work.  A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner.  ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
157 157  ** Cresnet Discovery is not working on ZUMNET-JBOXs.  Crestron has acknowledged a fix has been sent to QE.  Discovery must be fixed before ShowRunner can auto-discover hardware.
158 158  
159 159  ==== FAQ: ====
... ... @@ -163,7 +163,7 @@
163 163  * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
164 164  //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
165 165  
166 -==== ====
166 +==== ====
167 167  
168 168  ==== Topologies ====
169 169