Changes for page Crestron Zūm Wired

Last modified by Scott Kohlmann on 2023/04/20 22:22

From version 16.1
edited by Mark Kohlmann
on 2021/12/08 00:15
Change comment: Renamed back-links.
To version 12.1
edited by Mark Kohlmann
on 2021/05/06 15:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -9,7 +9,7 @@
9 9  
10 10  ==== Feature Matrix ====
11 11  
12 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App*
12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
13 13  |(% colspan="5" %)**Hardware Requirements**
14 14  |Requires ZUMNET JBox|Y|Y|Y|N
15 15  |Requires 3 or 4-Series Control System|Y|Y|N|N/A
... ... @@ -19,9 +19,9 @@
19 19  |Web Browser|(((
20 20  Crestron SmartGraphics XPanel
21 21  HTML5 UI
22 -)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI
22 +)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel
23 23  ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N
24 -|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
24 +|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
25 25  |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N
26 26  |(% colspan="5" %)**Features**
27 27  |Scene Recall|Y|Y|Y|Y
... ... @@ -44,7 +44,7 @@
44 44  Floor Hub: Category/Room|Category/Room|(((
45 45  N/A
46 46  )))
47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|SHOWRUNNER™: Automatic discovery (Pending)
47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|SHOWRUNNER™: Automatic discovery
48 48  Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
49 49  |Network Topology|(((
50 50  * Flat
... ... @@ -132,19 +132,8 @@
132 132  SHOWRUNNER™: Y
133 133  Floor Hub: N
134 134  )))|N|N/A
135 -|Minimum ZUM-NET Firmware|(((
136 -CNET Mode: ZUM-WIRED 1.00.09 puf
137 -ZUM Mode: ZUM-WIRED  1.xx.xxx puf (Pending)
138 -)))|(((
139 -SHOWRUNNER™: TBD
140 -Floor Hub: TBD
141 -)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
142 -|Minimum SHOWRUNNER™ Version|(((
143 -CNET Mode: 3.003
144 -ZUM Mode: TBD
145 -)))|N/A|N/A|N/A
146 -|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE
147 -|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM
135 +|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron
136 +|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A
148 148  
149 149  {{id name="caveats"/}}
150 150  
... ... @@ -151,19 +151,16 @@
151 151  ==== Caveats ====
152 152  
153 153  * Consult Chief Integrations to verify sequence of operations if there are any concerns.
154 -* Additional caveats:
155 -** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.
156 -** Raw Occupancy reporting does not work.  A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner.  ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.
157 -** Cresnet Discovery is not working on ZUMNET-JBOXs.  Crestron has acknowledged a fix has been sent to QE.  Discovery must be fixed before ShowRunner can auto-discover hardware.
143 +* Additional caveats TBD
158 158  
159 159  ==== FAQ: ====
160 160  
161 161  * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control?
162 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.  Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.  [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//
148 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.//
163 163  * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
164 164  //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
165 165  
166 -==== ====
152 +==== ====
167 167  
168 168  ==== Topologies ====
169 169