Changes for page Crestron Zūm Wired
Last modified by Scott Kohlmann on 2023/04/20 22:22
From version 13.1
edited by Mark Kohlmann
on 2021/10/05 22:11
on 2021/10/05 22:11
Change comment:
There is no comment for this version
To version 10.1
edited by Mark Kohlmann
on 2021/05/06 15:18
on 2021/05/06 15:18
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,7 +9,7 @@ 9 9 10 10 ==== Feature Matrix ==== 11 11 12 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB 4(Mirror Driver)|=ZUM-FLOOR-HUB4Only|=Zūm iOS/Android Setup App*12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="5" %)**Hardware Requirements** 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A ... ... @@ -19,7 +19,7 @@ 19 19 |Web Browser|((( 20 20 Crestron SmartGraphics XPanel 21 21 HTML5 UI 22 -)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel /HTML5 UI22 +)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel 23 23 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 24 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N ... ... @@ -44,7 +44,7 @@ 44 44 Floor Hub: Category/Room|Category/Room|((( 45 45 N/A 46 46 ))) 47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|SHOWRUNNER™: Automatic discovery(Pending)47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|SHOWRUNNER™: Automatic discovery 48 48 Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 49 49 |Network Topology|((( 50 50 * Flat ... ... @@ -59,8 +59,6 @@ 59 59 |Firmware Updates|PUF Tool 60 60 Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool 61 61 Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 -|Floorplans|Y|SHOWRUNNER™: Y 63 -Floor Hub: N|N|N/A 64 64 |(% colspan="5" %)**Calendar/Scheduling** 65 65 |Logic Type|Event Driven 66 66 Profile Support (Under Development)|SHOWRUNNER™: Event Driven ... ... @@ -77,8 +77,8 @@ 77 77 Floor Hub: N|N|N/A 78 78 |A/V Integration: RS-232|Y|((( 79 79 SHOWRUNNER™: Y 80 -Floor Hub: TBD81 -)))| TBD|N/A78 +Floor Hub: AVBRIDGE per Area 79 +)))|AVBRIDGE per Area|N/A 82 82 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 83 83 SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 84 84 Floor Hub: Y ... ... @@ -132,16 +132,8 @@ 132 132 SHOWRUNNER™: Y 133 133 Floor Hub: N 134 134 )))|N|N/A 135 -|Minimum ZUM-NET Firmware|((( 136 -CNET Mode: ZUM-WIRED 1.00.09 puf 137 -ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 -)))|N/A|See Crestron|See Crestron 139 -|Minimum SHOWRUNNER™ Version|((( 140 -CNET Mode: 3.003 141 -ZUM Mode: TBD 142 -)))|N/A|N/A|N/A 143 -|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE 144 -|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM 133 +|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron 134 +|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A 145 145 146 146 {{id name="caveats"/}} 147 147 ... ... @@ -148,20 +148,19 @@ 148 148 ==== Caveats ==== 149 149 150 150 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 151 -* Additional caveats: 152 -** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 153 -** Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 154 -** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 141 +* Additional caveats TBD 155 155 156 156 ==== FAQ: ==== 157 157 158 158 * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 159 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.//146 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required.// 160 160 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 161 161 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 162 162 150 +(% class="wikigeneratedid" %) 163 163 ==== ==== 164 164 153 +(% class="wikigeneratedid" %) 165 165 ==== Topologies ==== 166 166 167 167 **SHOWRUNNER™ Total Control (Control Subnet or Flat)**